Reference record for OID 1.3.6.1.2.1.33.1.8


parent
1.3.6.1.2.1.33.1 (upsObjects)
node code
8
node name
upsControl
dot oid
1.3.6.1.2.1.33.1.8
type
OBJECT IDENTIFIER
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) upsMIB(33) upsObjects(1) upsControl(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) upsMIB(33) upsObjects(1) upsControl(8)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) upsMIB(33) upsObjects(1) upsControl(8)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) upsMIB(33) upsObjects(1) upsControl(8)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) upsMIB(33) upsObjects(1) upsControl(8)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) upsMIB(33) upsObjects(1) upsControl(8)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/upsMIB/upsObjects/upsControl
  • /iso/identified-organization/dod/internet/mgmt/mib/upsMIB/upsObjects/upsControl
  • /iso/org/dod/internet/mgmt/mib-2/upsMIB/upsObjects/upsControl
  • /iso/org/dod/internet/mgmt/mib/upsMIB/upsObjects/upsControl
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/upsMIB/upsObjects/upsControl
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/upsMIB/upsObjects/upsControl
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/33/1/8

    Information by oid_info

    Automatically extracted from RFC1628

    Information by mibdepot

    upsControl OBJECT IDENTIFIER ::= { upsObjects 8 }

    Information by circitor

    upsControl OBJECT IDENTIFIER ::= { upsObjects 8 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Children (5)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.33.1.8.1 upsShutdownType 1 1 This object determines the nature of the action to be
    taken at the time when the countdown of the
    upsShutdownAfterDelay and upsRe…
    1.3.6.1.2.1.33.1.8.2 upsShutdownAfterDelay 1 1 Setting this object will shutdown (i.e., turn off)
    either the UPS output or the UPS system (as determined
    by the value of upsShut…
    1.3.6.1.2.1.33.1.8.3 upsStartupAfterDelay 1 1 Setting this object will start the output after the
    indicated number of seconds, including starting the
    UPS, if necessary. Setti…
    1.3.6.1.2.1.33.1.8.4 upsRebootWithDuration 1 1 Setting this object will immediately shutdown (i.e.,
    turn off) either the UPS output or the UPS system (as
    determined by the valu…
    1.3.6.1.2.1.33.1.8.5 upsAutoRestart 1 1 Setting this object to 'on' will cause the UPS system
    to restart after a shutdown if the shutdown occurred
    during a power loss as…

    Brothers (8)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.33.1.1 upsIdent 6 12 None
    1.3.6.1.2.1.33.1.2 upsBattery 7 14 None
    1.3.6.1.2.1.33.1.3 upsInput 3 11 None
    1.3.6.1.2.1.33.1.4 upsOutput 4 13 None
    1.3.6.1.2.1.33.1.5 upsBypass 3 10 None
    1.3.6.1.2.1.33.1.6 upsAlarm 5 60 None
    1.3.6.1.2.1.33.1.7 upsTest 7 23 None
    1.3.6.1.2.1.33.1.9 upsConfig 10 20 None