The type of marking technology used for this marking
sub-unit.
Parsed from file Printer-MIB.mib
Module: Printer-MIB
The type of marking technology used for this marking
sub-unit.
prtMarkerMarkTech OBJECT-TYPE
-- This value is a type 2 enumeration
SYNTAX INTEGER {
other(1),
unknown(2),
electrophotographicLED(3),
electrophotographicLaser(4),
electrophotographicOther(5),
impactMovingHeadDotMatrix9pin(6),
impactMovingHeadDotMatrix24pin(7),
impactMovingHeadDotMatrixOther(8),
impactMovingHeadFullyFormed(9),
impactBand(10),
impactOther(11),
inkjetAqueous(12),
inkjetSolid(13),
inkjetOther(14),
pen(15),
thermalTransfer(16),
thermalSensitive(17),
thermalDiffusion(18),
thermalOther(19),
electroerosion(20),
electrostatic(21),
photographicMicrofiche(22),
photographicImagesetter(23),
photographicOther(24),
ionDeposition(25),
eBeam(26),
typesetter(27)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of marking technology used for this marking sub-unit."
View at oid-info.com
The type of marking technology used for this marking sub-unit.
Parsed from file rfc1759.mib.txt
Company: None
Module: Printer-MIB
The type of marking technology used for this marking
sub-unit.
prtMarkerMarkTech OBJECT-TYPE SYNTAX PrtMarkerMarkTechTC MAX-ACCESS read-only STATUS current DESCRIPTION "The type of marking technology used for this marking sub-unit." ::= { prtMarkerEntry 2 }
prtMarkerMarkTech OBJECT-TYPE SYNTAX PrtMarkerMarkTechTC ACCESS read-only STATUS mandatory DESCRIPTION "The type of marking technology used for this marking sub-unit." ::= { prtMarkerEntry 2 }
Automatically extracted from RFC1759
prtMarkerMarkTech OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(2), electrophotographicLED(3), electrophotographicLaser(4), electrophotographicOther(5), impactMovingHeadDotMatrix9pin(6), impactMovingHeadDotMatrix24pin(7), impactMovingHeadDotMatrixOther(8), impactMovingHeadFullyFormed(9), impactBand(10), impactOther(11), inkjetAqueous(12), inkjetSolid(13), inkjetOther(14), pen(15), thermalTransfer(16), thermalSensitive(17), thermalDiffusion(18), thermalOther(19), electroerosion(20), electrostatic(21), photographicMicrofiche(22), photographicImagesetter(23), photographicOther(24), ionDeposition(25), eBeam(26), typesetter(27) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of marking technology used for this marking sub-unit." ::= { prtMarkerEntry 2 }
prtMarkerMarkTech OBJECT-TYPE SYNTAX PrtMarkerMarkTechTC MAX-ACCESS read-only STATUS current DESCRIPTION "The type of marking technology used for this marking sub-unit." ::= { prtMarkerEntry 2 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.43.10.2.1.1 | prtMarkerIndex | 0 | 0 | A unique value used by the printer to identify this marking SubUnit. Although these values may change due to a major reconfigura… |
1.3.6.1.2.1.43.10.2.1.3 | prtMarkerCounterUnit | 0 | 0 | The unit that will be used by the printer when reporting counter values for this marking sub-unit. The time units of measure are… |
1.3.6.1.2.1.43.10.2.1.4 | prtMarkerLifeCount | 0 | 0 | The count of the number of units of measure counted during the life of printer using units of measure as specified by CounterUnit. |
1.3.6.1.2.1.43.10.2.1.5 | prtMarkerPowerOnCount | 0 | 0 | The count of the number of units of measure counted since the equipment was most recently powered on using units of measure as sp… |
1.3.6.1.2.1.43.10.2.1.6 | prtMarkerProcessColorants | 0 | 0 | The number of process colors supported by this marker. A process color of 1 implies monochrome. The value of this object and Sp… |
1.3.6.1.2.1.43.10.2.1.7 | prtMarkerSpotColorants | 0 | 0 | The number of spot colors supported by this marker. The value of this object and ProcessColorants cannot both be 0. Must be 0 o… |
1.3.6.1.2.1.43.10.2.1.8 | prtMarkerAddressabilityUnit | 0 | 0 | The unit of measure of distances. |
1.3.6.1.2.1.43.10.2.1.9 | prtMarkerAddressabilityFeedDir | 0 | 0 | The number of addressable marking positions in the feed direction per 10000 units of measure specified by AddressabilityUnit. A… |
1.3.6.1.2.1.43.10.2.1.10 | prtMarkerAddressabilityXFeedDir | 0 | 0 | The number of addressable marking positions in the cross feed direction in 10000 units of measure specified by AddressabilityUnit… |
1.3.6.1.2.1.43.10.2.1.11 | prtMarkerNorthMargin | 0 | 0 | The margin, in units identified by AddressabilityUnit, from the leading edge of the medium as the medium flows throught the marki… |
1.3.6.1.2.1.43.10.2.1.12 | prtMarkerSouthMargin | 0 | 0 | The margin from the South edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the a… |
1.3.6.1.2.1.43.10.2.1.13 | prtMarkerWestMargin | 0 | 0 | The margin from the West edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the area… |
1.3.6.1.2.1.43.10.2.1.14 | prtMarkerEastMargin | 0 | 0 | The margin from the East edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the area… |
1.3.6.1.2.1.43.10.2.1.15 | prtMarkerStatus | 0 | 0 | The current status of this marker sub-unit. |