The maximum number of addressable marking positions in
the feed direction per 10000 units of measure specified
by prtMarkerAddressabilityUnit. A value of (-1) implies
'other' or 'infinite' while a value of (-2) implies
'unknown'.
Parsed from file Printer-MIB.mib
Module: Printer-MIB
The maximum number of addressable marking positions in the
feed direction per 10000 units of measure specified by
prtMarkerAddressabilityUnit. A value of (-1) implies 'other'
or 'infinite' while a value of (-2) implies 'unknown'.
NOTE: The above description has been modified from RFC 1759
for clarification.
prtMarkerAddressabilityFeedDir OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of addressable marking positions in the feed
direction per 10000 units of measure specified by
AddressabilityUnit. A value of (-1) implies other or
infinite while a value of (-2) implies unknown."
View at oid-info.com
The number of addressable marking positions in the feed
direction per 10000 units of measure specified by
AddressabilityUnit. A value of (-1) implies 'other' or
'infinite' while a value of (-2) implies 'unknown'.
Parsed from file rfc1759.mib.txt
Company: None
Module: Printer-MIB
The maximum number of addressable marking positions in the
feed direction per 10000 units of measure specified by
prtMarkerAddressabilityUnit. A value of (-1) implies 'other'
or 'infinite' while a value of (-2) implies 'unknown'.
NOTE: The above description has been modified from RFC 1759
for clarification.
prtMarkerAddressabilityFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of addressable marking positions in the feed direction per 10000 units of measure specified by prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or 'infinite' while a value of (-2) implies 'unknown'." ::= { prtMarkerEntry 9 }
prtMarkerAddressabilityFeedDir OBJECT-TYPE SYNTAX INTEGER(-2..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of addressable marking positions in the feed direction per 10000 units of measure specified by prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or 'infinite' while a value of (-2) implies 'unknown'. NOTE: The above description has been modified from RFC 1759 for clarification." ::= { prtMarkerEntry 9 }
Automatically extracted from RFC1759
prtMarkerAddressabilityFeedDir OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The number of addressable marking positions in the feed direction per 10000 units of measure specified by AddressabilityUnit. A value of (-1) implies 'other' or 'infinite' while a value of (-2) implies 'unknown'." ::= { prtMarkerEntry 9 }
prtMarkerAddressabilityFeedDir OBJECT-TYPE SYNTAX Integer32 (-2..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of addressable marking positions in the feed direction per 10000 units of measure specified by prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or 'infinite' while a value of (-2) implies 'unknown'. NOTE: The above description has been modified from RFC 1759 for clarification." ::= { prtMarkerEntry 9 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.43.10.2.1.1 | prtMarkerIndex | 0 | 0 | A unique value used by the printer to identify this marking SubUnit. Although these values may change due to a major reconfigura… |
1.3.6.1.2.1.43.10.2.1.2 | prtMarkerMarkTech | 0 | 0 | The type of marking technology used for this marking sub-unit. |
1.3.6.1.2.1.43.10.2.1.3 | prtMarkerCounterUnit | 0 | 0 | The unit that will be used by the printer when reporting counter values for this marking sub-unit. The time units of measure are… |
1.3.6.1.2.1.43.10.2.1.4 | prtMarkerLifeCount | 0 | 0 | The count of the number of units of measure counted during the life of printer using units of measure as specified by CounterUnit. |
1.3.6.1.2.1.43.10.2.1.5 | prtMarkerPowerOnCount | 0 | 0 | The count of the number of units of measure counted since the equipment was most recently powered on using units of measure as sp… |
1.3.6.1.2.1.43.10.2.1.6 | prtMarkerProcessColorants | 0 | 0 | The number of process colors supported by this marker. A process color of 1 implies monochrome. The value of this object and Sp… |
1.3.6.1.2.1.43.10.2.1.7 | prtMarkerSpotColorants | 0 | 0 | The number of spot colors supported by this marker. The value of this object and ProcessColorants cannot both be 0. Must be 0 o… |
1.3.6.1.2.1.43.10.2.1.8 | prtMarkerAddressabilityUnit | 0 | 0 | The unit of measure of distances. |
1.3.6.1.2.1.43.10.2.1.10 | prtMarkerAddressabilityXFeedDir | 0 | 0 | The number of addressable marking positions in the cross feed direction in 10000 units of measure specified by AddressabilityUnit… |
1.3.6.1.2.1.43.10.2.1.11 | prtMarkerNorthMargin | 0 | 0 | The margin, in units identified by AddressabilityUnit, from the leading edge of the medium as the medium flows throught the marki… |
1.3.6.1.2.1.43.10.2.1.12 | prtMarkerSouthMargin | 0 | 0 | The margin from the South edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the a… |
1.3.6.1.2.1.43.10.2.1.13 | prtMarkerWestMargin | 0 | 0 | The margin from the West edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the area… |
1.3.6.1.2.1.43.10.2.1.14 | prtMarkerEastMargin | 0 | 0 | The margin from the East edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the area… |
1.3.6.1.2.1.43.10.2.1.15 | prtMarkerStatus | 0 | 0 | The current status of this marker sub-unit. |