Reference record for OID 1.3.6.1.2.1.43.11.1.1.1


parent
1.3.6.1.2.1.43.11.1.1 (prtMarkerSuppliesEntry)
node code
1
node name
prtMarkerSuppliesIndex
dot oid
1.3.6.1.2.1.43.11.1.1.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) printmib(43) prtMarkerSupplies(11) prtMarkerSuppliesTable(1) prtMarkerSuppliesEntry(1) prtMarkerSuppliesIndex(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) current-printing-job-pages-printed(43) prtMarkerSupplies(11) prtMarkerSuppliesTable(1) prtMarkerSuppliesEntry(1) prtMarkerSuppliesIndex(1)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) job-info-change-id(43) prtMarkerSupplies(11) prtMarkerSuppliesTable(1) prtMarkerSuppliesEntry(1) prtMarkerSuppliesIndex(1)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) release-held-job(43) prtMarkerSupplies(11) prtMarkerSuppliesTable(1) prtMarkerSuppliesEntry(1) prtMarkerSuppliesIndex(1)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) printmib(43) prtMarkerSupplies(11) prtMarkerSuppliesTable(1) prtMarkerSuppliesEntry(1) prtMarkerSuppliesIndex(1)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) current-printing-job-pages-printed(43) prtMarkerSupplies(11) prtMarkerSuppliesTable(1) prtMarkerSuppliesEntry(1) prtMarkerSuppliesIndex(1)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) job-info-change-id(43) prtMarkerSupplies(11) prtMarkerSuppliesTable(1) prtMarkerSuppliesEntry(1) prtMarkerSuppliesIndex(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) release-held-job(43) prtMarkerSupplies(11) prtMarkerSuppliesTable(1) prtMarkerSuppliesEntry(1) prtMarkerSuppliesIndex(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/printmib/prtMarkerSupplies/prtMarkerSuppliesTable/prtMarkerSuppliesEntry/prtMarkerSuppliesIndex
  • /iso/identified-organization/dod/internet/mgmt/mib-2/current-printing-job-pages-printed/prtMarkerSupplies/prtMarkerSuppliesTable/prtMarkerSuppliesEntry/prtMarkerSuppliesIndex
  • ...skipped...
  • /iso/org/dod/internet/mgmt/mib-2/job-info-change-id/prtMarkerSupplies/prtMarkerSuppliesTable/prtMarkerSuppliesEntry/prtMarkerSuppliesIndex
  • /iso/org/dod/internet/mgmt/mib-2/release-held-job/prtMarkerSupplies/prtMarkerSuppliesTable/prtMarkerSuppliesEntry/prtMarkerSuppliesIndex
  • /iso/org/dod/internet/mgmt/mib/printmib/prtMarkerSupplies/prtMarkerSuppliesTable/prtMarkerSuppliesEntry/prtMarkerSuppliesIndex
  • /iso/org/dod/internet/mgmt/mib/current-printing-job-pages-printed/prtMarkerSupplies/prtMarkerSuppliesTable/prtMarkerSuppliesEntry/prtMarkerSuppliesIndex
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/job-info-change-id/prtMarkerSupplies/prtMarkerSuppliesTable/prtMarkerSuppliesEntry/prtMarkerSuppliesIndex
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/release-held-job/prtMarkerSupplies/prtMarkerSuppliesTable/prtMarkerSuppliesEntry/prtMarkerSuppliesIndex
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/43/11/1/1/1

    Description by circitor

    A unique value used by the printer to identify this
    marker supply. Although these values may change due to
    a major reconfiguration of the device (e.g. the addition
    of new marker supplies to the printer), values are
    expected to remain stable across successive power
    cycles.

    Parsed from file Printer-MIB.mib
    Module: Printer-MIB

    Description by cisco_v1

    A unique value used by the printer to identify this marker
    supply. Although these values may change due to a major
    reconfiguration of the device (e.g., the addition of new marker

    supplies to the printer), values SHOULD remain stable across
    successive printer power cycles.

    NOTE: The above description has been modified from RFC 1759
    for clarification.

    Description by oid_info

    prtMarkerSuppliesIndex OBJECT-TYPE
    SYNTAX Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
    "A unique value used by the printer to identify this marker
    supply. Although these values may change due to a major
    reconfiguration of the device (e.g. the addition of new marker
    supplies to the printer), values are expected to remain stable
    across successive printer power cycles."

    View at oid-info.com

    Description by mibdepot

    A unique value used by the printer to identify this marker
    supply. Although these values may change due to a major
    reconfiguration of the device (e.g. the addition of new marker
    supplies to the printer), values are expected to remain stable
    across successive printer power cycles.

    Parsed from file rfc1759.mib.txt
    Company: None
    Module: Printer-MIB

    Description by cisco

    A unique value used by the printer to identify this marker
    supply. Although these values may change due to a major
    reconfiguration of the device (e.g., the addition of new marker

    supplies to the printer), values SHOULD remain stable across
    successive printer power cycles.

    NOTE: The above description has been modified from RFC 1759
    for clarification.

    Information by circitor

    prtMarkerSuppliesIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this marker supply. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new marker supplies to the printer), values are expected to remain stable across successive power cycles." ::= { prtMarkerSuppliesEntry 1 }

    Information by cisco_v1

    prtMarkerSuppliesIndex OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS not-accessible STATUS mandatory DESCRIPTION "A unique value used by the printer to identify this marker supply. Although these values may change due to a major reconfiguration of the device (e.g., the addition of new marker supplies to the printer), values SHOULD remain stable across successive printer power cycles. NOTE: The above description has been modified from RFC 1759 for clarification." ::= { prtMarkerSuppliesEntry 1 }

    Information by oid_info

    Automatically extracted from RFC1759

    Information by mibdepot

    prtMarkerSuppliesIndex OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value used by the printer to identify this marker supply. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new marker supplies to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtMarkerSuppliesEntry 1 }

    Information by cisco

    prtMarkerSuppliesIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this marker supply. Although these values may change due to a major reconfiguration of the device (e.g., the addition of new marker supplies to the printer), values SHOULD remain stable across successive printer power cycles. NOTE: The above description has been modified from RFC 1759 for clarification." ::= { prtMarkerSuppliesEntry 1 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (8)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.43.11.1.1.2 prtMarkerSuppliesMarkerIndex 0 0 The value of prtMarkerIndex corresponding to the marking sub
    unit with which this marker supply sub-unit is associated.
    1.3.6.1.2.1.43.11.1.1.3 prtMarkerSuppliesColorantIndex 0 0 The value of prtMarkerColorantIndex
    corresponding to the colorant with which this
    marker supply sub-unit is associated. This val…
    1.3.6.1.2.1.43.11.1.1.4 prtMarkerSuppliesClass 0 0 Indicates whether this supply entity represents a
    supply that is consumed or a receptacle that is filled.
    1.3.6.1.2.1.43.11.1.1.5 prtMarkerSuppliesType 0 0 The type of this supply.
    1.3.6.1.2.1.43.11.1.1.6 prtMarkerSuppliesDescription 0 0 The description of this supply container/receptacle in the
    localization specified by prtGeneralCurrentLocalization.
    1.3.6.1.2.1.43.11.1.1.7 prtMarkerSuppliesSupplyUnit 0 0 Unit of this marker supply container/receptacle.
    1.3.6.1.2.1.43.11.1.1.8 prtMarkerSuppliesMaxCapacity 0 0 The maximum capacity of this supply container/receptacle
    expressed in SupplyUnit. If this supply
    container/receptacle can reliabl…
    1.3.6.1.2.1.43.11.1.1.9 prtMarkerSuppliesLevel 0 0 The current level if this supply is a container; the
    remaining space if this supply is a receptacle. If this
    supply container/rec…