Reference record for OID 1.3.6.1.2.1.43.11.1.1.9


parent
1.3.6.1.2.1.43.11.1.1 (prtMarkerSuppliesEntry)
node code
9
node name
prtMarkerSuppliesLevel
dot oid
1.3.6.1.2.1.43.11.1.1.9
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) printmib(43) prtMarkerSupplies(11) prtMarkerSuppliesTable(1) prtMarkerSuppliesEntry(1) prtMarkerSuppliesLevel(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) current-printing-job-pages-printed(43) prtMarkerSupplies(11) prtMarkerSuppliesTable(1) prtMarkerSuppliesEntry(1) prtMarkerSuppliesLevel(9)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) job-info-change-id(43) prtMarkerSupplies(11) prtMarkerSuppliesTable(1) prtMarkerSuppliesEntry(1) prtMarkerSuppliesLevel(9)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) release-held-job(43) prtMarkerSupplies(11) prtMarkerSuppliesTable(1) prtMarkerSuppliesEntry(1) prtMarkerSuppliesLevel(9)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) printmib(43) prtMarkerSupplies(11) prtMarkerSuppliesTable(1) prtMarkerSuppliesEntry(1) prtMarkerSuppliesLevel(9)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) current-printing-job-pages-printed(43) prtMarkerSupplies(11) prtMarkerSuppliesTable(1) prtMarkerSuppliesEntry(1) prtMarkerSuppliesLevel(9)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) job-info-change-id(43) prtMarkerSupplies(11) prtMarkerSuppliesTable(1) prtMarkerSuppliesEntry(1) prtMarkerSuppliesLevel(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) release-held-job(43) prtMarkerSupplies(11) prtMarkerSuppliesTable(1) prtMarkerSuppliesEntry(1) prtMarkerSuppliesLevel(9)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/printmib/prtMarkerSupplies/prtMarkerSuppliesTable/prtMarkerSuppliesEntry/prtMarkerSuppliesLevel
  • /iso/identified-organization/dod/internet/mgmt/mib-2/current-printing-job-pages-printed/prtMarkerSupplies/prtMarkerSuppliesTable/prtMarkerSuppliesEntry/prtMarkerSuppliesLevel
  • ...skipped...
  • /iso/org/dod/internet/mgmt/mib-2/job-info-change-id/prtMarkerSupplies/prtMarkerSuppliesTable/prtMarkerSuppliesEntry/prtMarkerSuppliesLevel
  • /iso/org/dod/internet/mgmt/mib-2/release-held-job/prtMarkerSupplies/prtMarkerSuppliesTable/prtMarkerSuppliesEntry/prtMarkerSuppliesLevel
  • /iso/org/dod/internet/mgmt/mib/printmib/prtMarkerSupplies/prtMarkerSuppliesTable/prtMarkerSuppliesEntry/prtMarkerSuppliesLevel
  • /iso/org/dod/internet/mgmt/mib/current-printing-job-pages-printed/prtMarkerSupplies/prtMarkerSuppliesTable/prtMarkerSuppliesEntry/prtMarkerSuppliesLevel
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/job-info-change-id/prtMarkerSupplies/prtMarkerSuppliesTable/prtMarkerSuppliesEntry/prtMarkerSuppliesLevel
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/release-held-job/prtMarkerSupplies/prtMarkerSuppliesTable/prtMarkerSuppliesEntry/prtMarkerSuppliesLevel
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/43/11/1/1/9

    Description by circitor

    The current level if this supply is a container;
    remaining space if this supply is a receptacle. If this
    supply container/receptacle can reliably sense this
    value, the value is reported by the printer and is read-
    only; otherwise, the value may be written (by a Remote
    Control Panel or a Management Application). The value (-
    1) means other and specifically indicates that the sub-
    unit places no restrictions on this parameter. The value
    (-2) means unknown. A value of (-3) means that the
    printer knows that there is some supply/remaining space,
    respectively.

    Parsed from file Printer-MIB.mib
    Module: Printer-MIB

    Description by cisco_v1

    The current level if this supply is a container; the remaining
    space if this supply is a receptacle. If this supply
    container/receptacle can reliably sense this value, the value
    is reported by the printer and is read-only; otherwise, the
    value may be written (by a Remote Control Panel or a Management
    Application). The value (-1) means other and specifically
    indicates that the sub-unit places no restrictions on this
    parameter. The value (-2) means unknown. A value of (-3) means
    that the printer knows that there is some supply/remaining
    space, respectively.

    Description by oid_info

    prtMarkerSuppliesLevel OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
    "The current level if this supply is a container; the
    remaining space if this supply is a receptacle. If this
    supply container/receptacle can reliably sense this
    value, the value is sensed by the printer and is
    read-only; otherwise, the value may be written (by a
    Remote Contol Panel or a Management Application). The
    value (-1) means other and specifically indicates that
    the sub-unit places no restrictions on this parameter.
    The value (-2) means unknown. A value of (-3) means that the
    printer knows that there is some supply/remaining space,
    respectively."

    View at oid-info.com

    Description by mibdepot

    The current level if this supply is a container; the
    remaining space if this supply is a receptacle. If this
    supply container/receptacle can reliably sense this
    value, the value is sensed by the printer and is
    read-only; otherwise, the value may be written (by a
    Remote Contol Panel or a Management Application). The
    value (-1) means other and specifically indicates that
    the sub-unit places no restrictions on this parameter.
    The value (-2) means unknown. A value of (-3) means that the
    printer knows that there is some supply/remaining space,
    respectively.

    Parsed from file rfc1759.mib.txt
    Company: None
    Module: Printer-MIB

    Description by cisco

    The current level if this supply is a container; the remaining
    space if this supply is a receptacle. If this supply
    container/receptacle can reliably sense this value, the value
    is reported by the printer and is read-only; otherwise, the
    value may be written (by a Remote Control Panel or a Management
    Application). The value (-1) means other and specifically
    indicates that the sub-unit places no restrictions on this
    parameter. The value (-2) means unknown. A value of (-3) means
    that the printer knows that there is some supply/remaining
    space, respectively.

    Information by circitor

    prtMarkerSuppliesLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The current level if this supply is a container; remaining space if this supply is a receptacle. If this supply container/receptacle can reliably sense this value, the value is reported by the printer and is read- only; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (- 1) means other and specifically indicates that the sub- unit places no restrictions on this parameter. The value (-2) means unknown. A value of (-3) means that the printer knows that there is some supply/remaining space, respectively." ::= { prtMarkerSuppliesEntry 9 }

    Information by cisco_v1

    prtMarkerSuppliesLevel OBJECT-TYPE SYNTAX INTEGER(-3..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The current level if this supply is a container; the remaining space if this supply is a receptacle. If this supply container/receptacle can reliably sense this value, the value is reported by the printer and is read-only; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. A value of (-3) means that the printer knows that there is some supply/remaining space, respectively." ::= { prtMarkerSuppliesEntry 9 }

    Information by oid_info

    Automatically extracted from RFC1759

    Information by mibdepot

    prtMarkerSuppliesLevel OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The current level if this supply is a container; the remaining space if this supply is a receptacle. If this supply container/receptacle can reliably sense this value, the value is sensed by the printer and is read-only; otherwise, the value may be written (by a Remote Contol Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. A value of (-3) means that the printer knows that there is some supply/remaining space, respectively." ::= { prtMarkerSuppliesEntry 9 }

    Information by cisco

    prtMarkerSuppliesLevel OBJECT-TYPE SYNTAX Integer32 (-3..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The current level if this supply is a container; the remaining space if this supply is a receptacle. If this supply container/receptacle can reliably sense this value, the value is reported by the printer and is read-only; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. A value of (-3) means that the printer knows that there is some supply/remaining space, respectively." ::= { prtMarkerSuppliesEntry 9 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (8)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.43.11.1.1.1 prtMarkerSuppliesIndex 0 0 A unique value used by the printer to identify this
    marker supply. Although these values may change due to
    a major reconfigurati…
    1.3.6.1.2.1.43.11.1.1.2 prtMarkerSuppliesMarkerIndex 0 0 The value of prtMarkerIndex corresponding to the marking sub
    unit with which this marker supply sub-unit is associated.
    1.3.6.1.2.1.43.11.1.1.3 prtMarkerSuppliesColorantIndex 0 0 The value of prtMarkerColorantIndex
    corresponding to the colorant with which this
    marker supply sub-unit is associated. This val…
    1.3.6.1.2.1.43.11.1.1.4 prtMarkerSuppliesClass 0 0 Indicates whether this supply entity represents a
    supply that is consumed or a receptacle that is filled.
    1.3.6.1.2.1.43.11.1.1.5 prtMarkerSuppliesType 0 0 The type of this supply.
    1.3.6.1.2.1.43.11.1.1.6 prtMarkerSuppliesDescription 0 0 The description of this supply container/receptacle in the
    localization specified by prtGeneralCurrentLocalization.
    1.3.6.1.2.1.43.11.1.1.7 prtMarkerSuppliesSupplyUnit 0 0 Unit of this marker supply container/receptacle.
    1.3.6.1.2.1.43.11.1.1.8 prtMarkerSuppliesMaxCapacity 0 0 The maximum capacity of this supply container/receptacle
    expressed in SupplyUnit. If this supply
    container/receptacle can reliabl…