This parameter indicates the status of the optical
output power for the client interface. It corresponds
to the client Tx LED status of the unit.
Can be on or off.
Parsed from file TRANSMODE1100.mib
Module: TRANSMODE1100
Vendor: Transmode Systems AB
Module: TRANSMODE1100
[Automatically extracted from oidview.com]
trm75xxTxClient OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical output power for the client interface. It corresponds to the client Tx LED status of the unit. Can be on or off." ::= {trm75xxEntry 12}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.1 | trm75xxRackNumber | 0 | 0 | This parameter indicates in what rack the unit is situated in. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.2 | trm75xxSlotNumber | 0 | 0 | This parameter indicates in what slot number the unit is situated in. Can be slot 1 - 8. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.3 | trm75xxRxLine | 0 | 0 | This parameter indicates the status of the optical input for the line interface. It corresponds to the client Rx LED status of th… |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.4 | trm75xxEstProtLine | 0 | 0 | This parameter indicates the Estimated Protocol for the line interface input. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.5 | trm75xxEstFibRateLine | 0 | 0 | This parameter indicates the Estimated Fiber Rate for the line interface input in Mbit/s. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.6 | trm75xxTxLine | 0 | 0 | This parameter indicates the status of the optical output power for the line interface. It corresponds to the line Tx LED status … |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.7 | trm75xxTxMode | 0 | 0 | This parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1) or disabled(2). norma… |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.8 | trm75xxWavelengthLine | 0 | 0 | This parameter indicates the nominal wavelength for the line interface transiever. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.9 | trm75xxRxClient | 0 | 0 | This parameter indicates the status of the optical input for the client interface. It corresponds to the client Rx LED status of … |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.10 | trm75xxEstProtClient | 0 | 0 | This parameter indicates the Estimated Protocol for the client interface input. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.11 | trm75xxEstFibRateClient | 0 | 0 | This parameter indicates the Estimated Fiber Rate for the client interface input in Mbit/s. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.13 | trm75xxTxModeClient | 0 | 0 | This object is obsolete and not used anymore. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.14 | trm75xxIDStringClient | 0 | 0 | This parameter identifies the equipment(ID String) connected to the client interface. Maximum number of characters is 20. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.15 | trm75xxIPAddressClient | 0 | 0 | This parameter indentifies the equipment(IP Address) connected to the client interface. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.16 | trm75xxWavelengthClient | 0 | 0 | This parameter indicates the nominal wavelength for the client interface transiever. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.17 | trm75xxSpeedLimit | 0 | 0 | This parameter indicates the speed limit set for this unit and is used to set a new speed limit. It generates an alarm and disabl… |