This parameter indicates the mode of the optical
transmitter for line and client TX.
Can be set to normal(1) or disabled(2).
normal (1): Optical output when receiving signal.
disabled(2): Optical output is OFF.
Parsed from file TRANSMODE1100.mib
Module: TRANSMODE1100
Vendor: Transmode Systems AB
Module: TRANSMODE1100
[Automatically extracted from oidview.com]
trm75xxTxMode OBJECT-TYPE SYNTAX TxMode75 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1) or disabled(2). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF." ::= {trm75xxEntry 7}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.1 | trm75xxRackNumber | 0 | 0 | This parameter indicates in what rack the unit is situated in. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.2 | trm75xxSlotNumber | 0 | 0 | This parameter indicates in what slot number the unit is situated in. Can be slot 1 - 8. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.3 | trm75xxRxLine | 0 | 0 | This parameter indicates the status of the optical input for the line interface. It corresponds to the client Rx LED status of th… |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.4 | trm75xxEstProtLine | 0 | 0 | This parameter indicates the Estimated Protocol for the line interface input. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.5 | trm75xxEstFibRateLine | 0 | 0 | This parameter indicates the Estimated Fiber Rate for the line interface input in Mbit/s. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.6 | trm75xxTxLine | 0 | 0 | This parameter indicates the status of the optical output power for the line interface. It corresponds to the line Tx LED status … |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.8 | trm75xxWavelengthLine | 0 | 0 | This parameter indicates the nominal wavelength for the line interface transiever. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.9 | trm75xxRxClient | 0 | 0 | This parameter indicates the status of the optical input for the client interface. It corresponds to the client Rx LED status of … |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.10 | trm75xxEstProtClient | 0 | 0 | This parameter indicates the Estimated Protocol for the client interface input. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.11 | trm75xxEstFibRateClient | 0 | 0 | This parameter indicates the Estimated Fiber Rate for the client interface input in Mbit/s. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.12 | trm75xxTxClient | 0 | 0 | This parameter indicates the status of the optical output power for the client interface. It corresponds to the client Tx LED sta… |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.13 | trm75xxTxModeClient | 0 | 0 | This object is obsolete and not used anymore. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.14 | trm75xxIDStringClient | 0 | 0 | This parameter identifies the equipment(ID String) connected to the client interface. Maximum number of characters is 20. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.15 | trm75xxIPAddressClient | 0 | 0 | This parameter indentifies the equipment(IP Address) connected to the client interface. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.16 | trm75xxWavelengthClient | 0 | 0 | This parameter indicates the nominal wavelength for the client interface transiever. |
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.17 | trm75xxSpeedLimit | 0 | 0 | This parameter indicates the speed limit set for this unit and is used to set a new speed limit. It generates an alarm and disabl… |