This parameter indicates the speed limit set for this unit
and is used to set a new speed limit.
It generates an alarm and disables Line and Client Tx if the
Client bitrate is higher than a predefined protocol.
The alarm is ceased and Tx is enabled again at a lower value
(hysteresis).
Speed Limit is deactivated if trm76xxTxMode is disabled(2) or
forcedon(3).
Speed Limit can be set in 4 modes to allow different protocols:
noLimit(1): Any protocol is allowed.
lowLimit(2): 100Base-FX, STM1/OC3, ESCON & Video 270Mb.
mediumLimit(3): All protocols above + STM4/OC-12.
highLimit(4): All protocols above + Fibre channel &
Gigabit Ethernet.
Parsed from file TRANSMODE1100.mib
Module: TRANSMODE1100
Vendor: Transmode Systems AB
Module: TRANSMODE1100
[Automatically extracted from oidview.com]
trm76xxSpeedLimit OBJECT-TYPE SYNTAX SpeedLimit76 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the speed limit set for this unit and is used to set a new speed limit. It generates an alarm and disables Line and Client Tx if the Client bitrate is higher than a predefined protocol. The alarm is ceased and Tx is enabled again at a lower value (hysteresis). Speed Limit is deactivated if trm76xxTxMode is disabled(2) or forcedon(3). Speed Limit can be set in 4 modes to allow different protocols: noLimit(1): Any protocol is allowed. lowLimit(2): 100Base-FX, STM1/OC3, ESCON & Video 270Mb. mediumLimit(3): All protocols above + STM4/OC-12. highLimit(4): All protocols above + Fibre channel & Gigabit Ethernet." ::= {trm76xxEntry 11}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.1 | trm76xxRackNumber | 0 | 0 | This parameter indicates in what rack the unit is situated in. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.2 | trm76xxSlotNumber | 0 | 0 | This parameter indicates in what slot number the unit is situated in. Can be any of slot 1 - 8. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.3 | trm76xxTemperature | 0 | 0 | This parameter indicates the temperature measured by the unit in deg. C or deg. F. See trmSubrackConfigTemp if deg. Celsius or Fa… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.4 | trm76xxCDR | 0 | 0 | This parameter indicates the working mode of the CDR clock recovery circuit. Can be auto3R(1), bypass2R(2), custom(3),fddiOR100Ba… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.5 | trm76xxCustomFibRate | 0 | 0 | This parameter is used to set the working mode of the CDR clock recovery circuit(Custom mode). Custom mode can be set between 300… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.6 | trm76xxTxMode | 0 | 0 | This parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1), disabled(2) or forc… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.7 | trm76xxLineLoopMode | 0 | 0 | This parameter is used to set the line loop mode. Can be set to normal(1) or looptest(2). normal(1): The line loop test function … |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.8 | trm76xxSwReset | 0 | 0 | Used to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.9 | trm76xxRxLine | 0 | 0 | This parameter indicates the status of the optical input for the line interface. It corresponds to the client Rx LED status of th… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.10 | trm76xxOpticalInPowLine | 0 | 0 | This parameter indicates the Optical input power for the line interface. When the Optical input power is to low to measure this p… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.12 | trm76xxEstProtLine | 0 | 0 | This parameter indicates the Estimated Protocol for the line interface Rx. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.13 | trm76xxEstFibRateLine | 0 | 0 | This parameter indicates the Estimated Fiber Rate for the line interface Rx in Mbit/s. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.14 | trm76xxTxLine | 0 | 0 | This parameter indicates the status of the optical output power for the line interface. It corresponds to the line Tx LED status … |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.15 | trm76xxOpticalOutPowLine | 0 | 0 | This parameter indicates the optical output power for the line interface. If data not is available yet this parameter is -1(-0.1 … |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.16 | trm76xxProdOutPowLine | 0 | 0 | This parameter indicates the production output power for the line interface. If data not is valid yet this parameter is -1 (-0.1 … |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.17 | trm76xxLaserBiasCurLine | 0 | 0 | This parameter indicates the laser bias current for the line interface. If this parameter is 5450(545 mA) the laser bias current … |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.18 | trm76xxProdLaserBiasCurLine | 0 | 0 | This parameter indicates the production laser bias current for the line interface. Divide this value by 10 to show the laser bias… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.19 | trm76xxWavelengthLine | 0 | 0 | This parameter indicates the nominal wavelength for the line interface transiever. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.20 | trm76xxRxClient | 0 | 0 | This parameter indicates the status of the optical input for the client interface. It corresponds to the client Rx LED status of … |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.21 | trm76xxEstProtClient | 0 | 0 | This parameter indicates the Estimated Protocol for the client interface Rx. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.22 | trm76xxEstFibRateClient | 0 | 0 | This parameter indicates the Estimated Fiber Rate for the client interface Rx in Mbit/s. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.23 | trm76xxTxClient | 0 | 0 | This parameter indicates the status of the optical output power for the client interface. It corresponds to the client Tx LED sta… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.24 | trm76xxIDStringClient | 0 | 0 | This parameter identifies the equipment(ID String) connected to the client interface. Maximum number of characters is 20. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.25 | trm76xxIPAddressClient | 0 | 0 | This parameter indentifies the equipment(IP Address) connected to the client interface. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.26 | trm76xxWavelengthClient | 0 | 0 | This parameter indicates the nominal wavelength for the client interface transiever. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.27 | trm76xxOpticalInPowClient | 0 | 0 | This parameter indicates the Optical input power for the client interface. When the Optical input power is to low to measure this… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.28 | trm76xxOpticalOutPowClient | 0 | 0 | This parameter indicates the optical output power for the client interface. If data not is available yet this parameter is -1(-0.… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.29 | trm76xxLaserBiasCurClient | 0 | 0 | This parameter indicates the laser bias current for the client interface. If this parameter is 5450(545 mA) the laser bias curren… |