This parameter indicates the status of the optical
input for the line interface. It corresponds to the
client Rx LED status of the unit.
Can be Receiving or Not receiving.
Parsed from file TRANSMODE1100.mib
Module: TRANSMODE1100
Vendor: Transmode Systems AB
Module: TRANSMODE1100
[Automatically extracted from oidview.com]
trm76xxRxLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical input for the line interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving." ::= {trm76xxEntry 9}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.1 | trm76xxRackNumber | 0 | 0 | This parameter indicates in what rack the unit is situated in. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.2 | trm76xxSlotNumber | 0 | 0 | This parameter indicates in what slot number the unit is situated in. Can be any of slot 1 - 8. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.3 | trm76xxTemperature | 0 | 0 | This parameter indicates the temperature measured by the unit in deg. C or deg. F. See trmSubrackConfigTemp if deg. Celsius or Fa… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.4 | trm76xxCDR | 0 | 0 | This parameter indicates the working mode of the CDR clock recovery circuit. Can be auto3R(1), bypass2R(2), custom(3),fddiOR100Ba… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.5 | trm76xxCustomFibRate | 0 | 0 | This parameter is used to set the working mode of the CDR clock recovery circuit(Custom mode). Custom mode can be set between 300… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.6 | trm76xxTxMode | 0 | 0 | This parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1), disabled(2) or forc… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.7 | trm76xxLineLoopMode | 0 | 0 | This parameter is used to set the line loop mode. Can be set to normal(1) or looptest(2). normal(1): The line loop test function … |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.8 | trm76xxSwReset | 0 | 0 | Used to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.10 | trm76xxOpticalInPowLine | 0 | 0 | This parameter indicates the Optical input power for the line interface. When the Optical input power is to low to measure this p… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.11 | trm76xxSpeedLimit | 0 | 0 | This parameter indicates the speed limit set for this unit and is used to set a new speed limit. It generates an alarm and disabl… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.12 | trm76xxEstProtLine | 0 | 0 | This parameter indicates the Estimated Protocol for the line interface Rx. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.13 | trm76xxEstFibRateLine | 0 | 0 | This parameter indicates the Estimated Fiber Rate for the line interface Rx in Mbit/s. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.14 | trm76xxTxLine | 0 | 0 | This parameter indicates the status of the optical output power for the line interface. It corresponds to the line Tx LED status … |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.15 | trm76xxOpticalOutPowLine | 0 | 0 | This parameter indicates the optical output power for the line interface. If data not is available yet this parameter is -1(-0.1 … |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.16 | trm76xxProdOutPowLine | 0 | 0 | This parameter indicates the production output power for the line interface. If data not is valid yet this parameter is -1 (-0.1 … |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.17 | trm76xxLaserBiasCurLine | 0 | 0 | This parameter indicates the laser bias current for the line interface. If this parameter is 5450(545 mA) the laser bias current … |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.18 | trm76xxProdLaserBiasCurLine | 0 | 0 | This parameter indicates the production laser bias current for the line interface. Divide this value by 10 to show the laser bias… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.19 | trm76xxWavelengthLine | 0 | 0 | This parameter indicates the nominal wavelength for the line interface transiever. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.20 | trm76xxRxClient | 0 | 0 | This parameter indicates the status of the optical input for the client interface. It corresponds to the client Rx LED status of … |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.21 | trm76xxEstProtClient | 0 | 0 | This parameter indicates the Estimated Protocol for the client interface Rx. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.22 | trm76xxEstFibRateClient | 0 | 0 | This parameter indicates the Estimated Fiber Rate for the client interface Rx in Mbit/s. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.23 | trm76xxTxClient | 0 | 0 | This parameter indicates the status of the optical output power for the client interface. It corresponds to the client Tx LED sta… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.24 | trm76xxIDStringClient | 0 | 0 | This parameter identifies the equipment(ID String) connected to the client interface. Maximum number of characters is 20. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.25 | trm76xxIPAddressClient | 0 | 0 | This parameter indentifies the equipment(IP Address) connected to the client interface. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.26 | trm76xxWavelengthClient | 0 | 0 | This parameter indicates the nominal wavelength for the client interface transiever. |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.27 | trm76xxOpticalInPowClient | 0 | 0 | This parameter indicates the Optical input power for the client interface. When the Optical input power is to low to measure this… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.28 | trm76xxOpticalOutPowClient | 0 | 0 | This parameter indicates the optical output power for the client interface. If data not is available yet this parameter is -1(-0.… |
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.29 | trm76xxLaserBiasCurClient | 0 | 0 | This parameter indicates the laser bias current for the client interface. If this parameter is 5450(545 mA) the laser bias curren… |