OID reference

ascLineVolts

1.3.6.1.4.1.1206.4.2.1.12.8

Description

<Definition> Indicates the voltage, in 0.1 RMS volt units, measured on the incoming power line for the CU. This object shall only be used to indicate A/C power conditions. If the line power is DC, this object shall not apply (i.e., this object will either not be supported or this object will have a value of 3001). <Va…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.1.12 (cabinetEnvironment)
Node code
8
Node name
ascLineVolts
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.1.12.8
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.1.12.8
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 1 12 8}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) cabinetEnvironment(12) ascLineVolts(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) cabinetEnvironment(12) ascLineVolts(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) cabinetEnvironment(12) ascLineVolts(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) cabinetEnvironment(12) ascLineVolts(8)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) cabinetEnvironment(12) ascLineVolts(8)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) cabinetEnvironment(12) ascLineVolts(8)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) cabinetEnvironment(12) ascLineVolts(8)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) cabinetEnvironment(12) ascLineVolts(8)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) cabinetEnvironment(12) ascLineVolts(8)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) cabinetEnvironment(12) ascLineVolts(8)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) cabinetEnvironment(12) ascLineVolts(8)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) cabinetEnvironment(12) ascLineVolts(8)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) cabinetEnvironment(12) ascLineVolts(8)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) cabinetEnvironment(12) ascLineVolts(8)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) cabinetEnvironment(12) ascLineVolts(8)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) cabinetEnvironment(12) ascLineVolts(8)}
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/1/12/8
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/1/12/8
  • /ISO/3/6/1/4/1/1206/4/2/1/12/8
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/asc/cabinetEnvironment/ascLineVolts
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/asc/cabinetEnvironment/ascLineVolts
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/asc/cabinetEnvironment/ascLineVolts
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/asc/cabinetEnvironment/ascLineVolts
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/asc/cabinetEnvironment/ascLineVolts
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/asc/cabinetEnvironment/ascLineVolts
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/asc/cabinetEnvironment/ascLineVolts
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/asc/cabinetEnvironment/ascLineVolts
  • /iso/org/dod/internet/private/enterprise/1206/transportation/devices/asc/cabinetEnvironment/ascLineVolts
  • /iso/org/dod/internet/private/enterprise/nema/transportation/devices/asc/cabinetEnvironment/ascLineVolts
  • /iso/org/dod/internet/private/enterprises/1206/transportation/devices/asc/cabinetEnvironment/ascLineVolts
  • /iso/org/dod/internet/private/enterprises/nema/transportation/devices/asc/cabinetEnvironment/ascLineVolts
  • /iso/org/dod/internet/private/ldap-enterprise/1206/transportation/devices/asc/cabinetEnvironment/ascLineVolts
  • /iso/org/dod/internet/private/ldap-enterprise/nema/transportation/devices/asc/cabinetEnvironment/ascLineVolts
  • /iso/org/dod/internet/private/vendor-objects/1206/transportation/devices/asc/cabinetEnvironment/ascLineVolts
  • /iso/org/dod/internet/private/vendor-objects/nema/transportation/devices/asc/cabinetEnvironment/ascLineVolts
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
mandatory
Default value
6001
Allowed ranges
0–6001

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.1.12.8.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

ascLineVolts · mandatory

ascLineVolts OBJECT-TYPE
      SYNTAX       INTEGER (0..6001)
      ACCESS       read-only
      STATUS       mandatory
      DESCRIPTION "<Definition> Indicates the voltage, in 0.1 RMS volt units,
             measured on the incoming power line for the CU. This object shall
             only be used to indicate A/C power conditions. If the line power
             is DC, this object shall not apply (i.e., this object will either
             not be supported or this object will have a value of 3001).
      <Valid Value Rule> Values 0 through 5999 shall indicate valid values.
             The value 6000 shall mean a voltage of 600.0 Vrms or greater. The
             value of 6001 shall indicate an error condition or missing value.
      <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.12.8
      <Unit>0.1 Volts Root Mean Squared (Vrms)"



                                                                                          

                  
        

      DEFVAL      { 6001 }
::= { cabinetEnvironment 8 }

ascLineVolts · mandatory

ascLineVolts OBJECT-TYPE
      SYNTAX       INTEGER (0..6001)
      ACCESS       read-only
      STATUS       mandatory
      DESCRIPTION "<Definition> Indicates the voltage, in 0.1 RMS volt units,
             measured on the incoming power line for the CU. This object shall
             only be used to indicate A/C power conditions. If the line power
             is DC, this object shall not apply (i.e., this object will either
             not be supported or this object will have a value of 3001).
      <Valid Value Rule> Values 0 through 5999 shall indicate valid values.
             The value 6000 shall mean a voltage of 600.0 Vrms or greater. The
             value of 6001 shall indicate an error condition or missing value.
      <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.12.8
      <Object Type> S
      <Unit>0.1 Volts Root Mean Squared (Vrms)"
      DEFVAL       { 6001 }
::= { cabinetEnvironment 8 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

<Definition> Indicates the voltage, in 0.1 RMS volt units, measured on the incoming power line for the CU. This object shall only be used to indicate A/C power conditions. If the line power is DC, this object shall not apply (i.e., this object will either not be supported or this object will have a value of 3001). <Valid Value Rule> Values 0 through 5999 shall indicate valid values. The value 6000 shall mean a voltage of 600.0 Vrms or greater. The value of 6001 shall indicate an error condition or missing value. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.12.8 <Unit>0.1 Volts Root Mean Squared (Vrms)

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 2

<Definition> Indicates the voltage, in 0.1 RMS volt units, measured on the incoming power line for the CU. This object shall only be used to indicate A/C power conditions. If the line power is DC, this object shall not apply (i.e., this object will either not be supported or this object will have a value of 3001). <Valid Value Rule> Values 0 through 5999 shall indicate valid values. The value 6000 shall mean a voltage of 600.0 Vrms or greater. The value of 6001 shall indicate an error condition or missing value. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.12.8 <Object Type> S <Unit>0.1 Volts Root Mean Squared (Vrms)

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 1

ascLineVolts · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: ascLineVolts

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ascLineVolts",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "6001",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> Indicates the voltage, in 0.1 RMS volt units, measured on the incoming power line for the CU. This object shall only be used to indicate A/C power conditions. If the line power is DC, this object shall not apply (i.e., this object will either not be supported or this object will have a value of 3001). <Valid Value Rule> Values 0 through 5999 shall indicate valid values. The value 6000 shall mean a voltage of 600.0 Vrms or greater. The value of 6001 shall indicate an error condition or missing value. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.12.8 <Unit>0.1 Volts Root Mean Squared (Vrms)\"",
    "DEFVAL",
    "{",
    "6001",
    "}",
    "::=",
    "{",
    "cabinetEnvironment",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            6001
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> Indicates the voltage, in 0.1 RMS volt units, measured on the incoming power line for the CU. This object shall only be used to indicate A/C power conditions. If the line power is DC, this object shall not apply (i.e., this object will either not be supported or this object will have a value of 3001). <Valid Value Rule> Values 0 through 5999 shall indicate valid values. The value 6000 shall mean a voltage of 600.0 Vrms or greater. The value of 6001 shall indicate an error condition or missing value. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.12.8 <Unit>0.1 Volts Root Mean Squared (Vrms)"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      6001
    ]
  ]
}
Records for description 2NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 2

ascLineVolts · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: ascLineVolts

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ascLineVolts",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "6001",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> Indicates the voltage, in 0.1 RMS volt units, measured on the incoming power line for the CU. This object shall only be used to indicate A/C power conditions. If the line power is DC, this object shall not apply (i.e., this object will either not be supported or this object will have a value of 3001). <Valid Value Rule> Values 0 through 5999 shall indicate valid values. The value 6000 shall mean a voltage of 600.0 Vrms or greater. The value of 6001 shall indicate an error condition or missing value. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.12.8 <Object Type> S <Unit>0.1 Volts Root Mean Squared (Vrms)\"",
    "DEFVAL",
    "{",
    "6001",
    "}",
    "::=",
    "{",
    "cabinetEnvironment",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            6001
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> Indicates the voltage, in 0.1 RMS volt units, measured on the incoming power line for the CU. This object shall only be used to indicate A/C power conditions. If the line power is DC, this object shall not apply (i.e., this object will either not be supported or this object will have a value of 3001). <Valid Value Rule> Values 0 through 5999 shall indicate valid values. The value 6000 shall mean a voltage of 600.0 Vrms or greater. The value of 6001 shall indicate an error condition or missing value. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.12.8 <Object Type> S <Unit>0.1 Volts Root Mean Squared (Vrms)"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      6001
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (8)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.1.12.1 maxCabinetEnvironDevices00
1.3.6.1.4.1.1206.4.2.1.12.2 cabinetEnvironDevicesTable17
1.3.6.1.4.1.1206.4.2.1.12.3 maxCabinetTempSensors00
1.3.6.1.4.1.1206.4.2.1.12.4 cabinetTempSensorStatusTable17
1.3.6.1.4.1.1206.4.2.1.12.5 maxCabinetHumiditySensors00
1.3.6.1.4.1.1206.4.2.1.12.6 cabinetHumiditySensorStatusTable16
1.3.6.1.4.1.1206.4.2.1.12.7 ascPowerSource00
1.3.6.1.4.1.1206.4.2.1.12.9 atccLEDMode00