Status in source: mandatory.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"vehicleDetectorControlGroupActuation",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"255",
")",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"<Definition> This object is used to allow a remote entity to place an actuation on a vehicle detector. When a bit = 1, an actuation is placed on the vehicle detector. When a bit = 0, no actuation is placed on the vehicle detector. An NTCIP actuation is placed using this object and is treated the same as an external actuation, so all detector functions are still applicable, including delay, extension, diagnostics, and report objects, such as vehicleDetectorStatusGroupActive and volumeOccupancyReport. Bit 7: Det # = ( vehicleDetectorControlGroupNumber * 8) Bit 6: Det # = ( vehicleDetectorControlGroupNumber * 8) - 1 Bit 5: Det # = ( vehicleDetectorControlGroupNumber * 8) - 2 Bit 4: Det # = ( vehicleDetectorControlGroupNumber * 8) - 3 Bit 3: Det # = ( vehicleDetectorControlGroupNumber * 8) - 4 Bit 2: Det # = ( vehicleDetectorControlGroupNumber * 8) - 5 Bit 1: Det # = ( vehicleDetectorControlGroupNumber * 8) - 6 Bit 0: Det # = ( vehicleDetectorControlGroupNumber * 8) – 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.2.12.1.2\"",
"::=",
"{",
"vehicleDetectorControlGroupEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
255
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"<Definition> This object is used to allow a remote entity to place an actuation on a vehicle detector. When a bit = 1, an actuation is placed on the vehicle detector. When a bit = 0, no actuation is placed on the vehicle detector. An NTCIP actuation is placed using this object and is treated the same as an external actuation, so all detector functions are still applicable, including delay, extension, diagnostics, and report objects, such as vehicleDetectorStatusGroupActive and volumeOccupancyReport. Bit 7: Det # = ( vehicleDetectorControlGroupNumber * 8) Bit 6: Det # = ( vehicleDetectorControlGroupNumber * 8) - 1 Bit 5: Det # = ( vehicleDetectorControlGroupNumber * 8) - 2 Bit 4: Det # = ( vehicleDetectorControlGroupNumber * 8) - 3 Bit 3: Det # = ( vehicleDetectorControlGroupNumber * 8) - 4 Bit 2: Det # = ( vehicleDetectorControlGroupNumber * 8) - 5 Bit 1: Det # = ( vehicleDetectorControlGroupNumber * 8) - 6 Bit 0: Det # = ( vehicleDetectorControlGroupNumber * 8) – 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.2.12.1.2"
],
null,
null,
null,
null
]
}