Status in source: mandatory.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"patternCycleTime",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"255",
")",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"<Definition> The patternCycleTime object specifies the length of the pattern cycle in seconds (NEMA TS 2 range: 30-255). A pattern cycle time less than adequate to service the minimum requirements of all phases shall result in Free mode. While this condition exists, the Local Free bit of unitAlarmStatus1 and the Local Override bit of shortAlarmStatus shall be set to one (1). The minimum requirements of a phase with a not-actuated ped include Minimum Green, Walk, Pedestrian Clear, Yellow Clearance, and Red Clearance; the minimum requirements of a phase with an actuated pedestrian include Minimum Green, Yellow Clearance, and Red Clearance. If the pattern cycle time is zero and the associated split table (if any) contains values greater than zero, then the CU shall utilize the split time values as maximum values for each phase. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.4.7.1.2 <Unit> second\"",
"REFERENCE",
"\"NEMA TS 2 Clause 3.6.2.1.1\"",
"::=",
"{",
"patternEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
255
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"<Definition> The patternCycleTime object specifies the length of the pattern cycle in seconds (NEMA TS 2 range: 30-255). A pattern cycle time less than adequate to service the minimum requirements of all phases shall result in Free mode. While this condition exists, the Local Free bit of unitAlarmStatus1 and the Local Override bit of shortAlarmStatus shall be set to one (1). The minimum requirements of a phase with a not-actuated ped include Minimum Green, Walk, Pedestrian Clear, Yellow Clearance, and Red Clearance; the minimum requirements of a phase with an actuated pedestrian include Minimum Green, Yellow Clearance, and Red Clearance. If the pattern cycle time is zero and the associated split table (if any) contains values greater than zero, then the CU shall utilize the split time values as maximum values for each phase. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.4.7.1.2 <Unit> second"
],
[
"REFERENCE",
"NEMA TS 2 Clause 3.6.2.1.1"
],
null,
null,
null
]
}