OID reference

splitTime

1.3.6.1.4.1.1206.4.2.1.4.9.1.3

Description

The time in seconds the splitPhase is allowed to receive (i.e. before a Force Off is applied) when constant demands exist on all phases. In floating coordForceMode, this is always the maximum time a non-coordinated phase is allowed to receive. In fixed coordForceMode, the actual allowed time may be longer if a previou…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.1.4.9.1 (splitEntry)
Node code
3
Node name
splitTime
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.1.4.9.1.3
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.1.4.9.1.3
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 1 4 9 1 3}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) coord(4) splitTable(9) splitEntry(1) splitTime(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) coord(4) splitTable(9) splitEntry(1) splitTime(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) coord(4) splitTable(9) splitEntry(1) splitTime(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) coord(4) splitTable(9) splitEntry(1) splitTime(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) coord(4) splitTable(9) splitEntry(1) splitTime(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) coord(4) splitTable(9) splitEntry(1) splitTime(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) coord(4) splitTable(9) splitEntry(1) splitTime(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) coord(4) splitTable(9) splitEntry(1) splitTime(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) coord(4) splitTable(9) splitEntry(1) splitTime(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) coord(4) splitTable(9) splitEntry(1) splitTime(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) coord(4) splitTable(9) splitEntry(1) splitTime(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) coord(4) splitTable(9) splitEntry(1) splitTime(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) coord(4) splitTable(9) splitEntry(1) splitTime(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) coord(4) splitTable(9) splitEntry(1) splitTime(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) coord(4) splitTable(9) splitEntry(1) splitTime(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) coord(4) splitTable(9) splitEntry(1) splitTime(3)}
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/1/4/9/1/3
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/1/4/9/1/3
  • /ISO/3/6/1/4/1/1206/4/2/1/4/9/1/3
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/asc/coord/splitTable/splitEntry/splitTime
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/asc/coord/splitTable/splitEntry/splitTime
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/asc/coord/splitTable/splitEntry/splitTime
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/asc/coord/splitTable/splitEntry/splitTime
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/asc/coord/splitTable/splitEntry/splitTime
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/asc/coord/splitTable/splitEntry/splitTime
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/asc/coord/splitTable/splitEntry/splitTime
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/asc/coord/splitTable/splitEntry/splitTime
  • /iso/org/dod/internet/private/enterprise/1206/transportation/devices/asc/coord/splitTable/splitEntry/splitTime
  • /iso/org/dod/internet/private/enterprise/nema/transportation/devices/asc/coord/splitTable/splitEntry/splitTime
  • /iso/org/dod/internet/private/enterprises/1206/transportation/devices/asc/coord/splitTable/splitEntry/splitTime
  • /iso/org/dod/internet/private/enterprises/nema/transportation/devices/asc/coord/splitTable/splitEntry/splitTime
  • /iso/org/dod/internet/private/ldap-enterprise/1206/transportation/devices/asc/coord/splitTable/splitEntry/splitTime
  • /iso/org/dod/internet/private/ldap-enterprise/nema/transportation/devices/asc/coord/splitTable/splitEntry/splitTime
  • /iso/org/dod/internet/private/vendor-objects/1206/transportation/devices/asc/coord/splitTable/splitEntry/splitTime
  • /iso/org/dod/internet/private/vendor-objects/nema/transportation/devices/asc/coord/splitTable/splitEntry/splitTime
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory, optional

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — NTCIP published standard MIB annexes (reviewed modules)

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory
Allowed ranges
0–255

Variant 2 — NTCIP published standard MIB annexes (reviewed modules)

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
optional
Allowed ranges
0–255

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In NTCIP1202-v03, the row index consists of these components in order:

  1. splitNumber (INTEGER): one numeric subidentifier for the non-negative value.
  2. splitPhase (INTEGER): one numeric subidentifier for the non-negative value.

An instance has the form .1.3.6.1.4.1.1206.4.2.1.4.9.1.3.<splitNumber>.<splitPhase>. Use values present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.1.4.9.1.3

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 4 distinct definitions; some records may not include a definition.

Show 4 published definitions

splitTime · mandatory

splitTime OBJECT-TYPE
        SYNTAX INTEGER (0..255)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
           "The time in seconds the splitPhase is allowed to receive (i.e. before a Force Off is applied)
           when constant demands exist on all phases. In floating coordForceMode, this is always the
           maximum time a non-coordinated phase is allowed to receive. In fixed coordForceMode, the
           actual allowed time may be longer if a previous phase gapped out.
           The splitTime includes all phase clearance times for the associated phase. The split time
           shall be longer than the sum of the phase minimum service requirements (Minimum Green,
           Yellow Change, Red Clearance, Walk, Pedestrian Clearance, etc.) for the phase. When the
           time is NOT adequate to service the minimum service requirements of the phase, Free
           Mode shall be the result.
           If the cycleTime entry of the associated patternTable entry is zero (i.e. the device is in Free
           Mode), then the value of this object shall be applied as a maximum time for the associated
           phase.
           If the critical path through the phase diagram is less than the cycleTime entry of the
           associated patternTable entry, all extra time is allotted to the coordination phase in each
           ring.
           If the critical path through the phase diagram is greater than the cycleTime entry of the
           associated patternTable entry (and the cycleTime is not zero) the device shall operate in the
           Free Mode.

                                                                                                TS 3.5-1996
                                                                                                          

               While the Free Mode condition exists, the Local Override bit of shortAlarm shall be set to
               one (1)."
          REFERENCE
               "NEMA TS 2 Clause 3.6.2.1.2"
::= { splitEntry 3 }

splitTime · mandatory

splitTime   OBJECT-TYPE
      SYNTAX INTEGER (0..255)
      ACCESS read-write
      STATUS mandatory
      DESCRIPTION "<Definition> The time in seconds the splitPhase is allowed
            to receive (i.e. before a Force Off is applied) when constant
            demands exist on all phases. In floating coordForceMode, this is
            always the maximum time a non-coordinated phase is allowed to
            receive. In fixed coordForceMode, the actual allowed time may be
            longer if a previous phase gapped out.

               The splitTime includes all phase clearance times for the
               associated phase. The split time shall be longer than the sum of
               the phase minimum service requirements for the phase. When the
               time is NOT adequate to service the minimum service requirements
               of the phase, Free Mode shall be the result. The minimum
               requirements of a phase with a not-actuated ped include Minimum
               Green, Walk, Pedestrian Clear, Yellow Clearance, and Red
               Clearance; the minimum requirements of a phase with an actuated
               pedestrian include Minimum Green, Yellow Clearance, and Red
               Clearance.

               If the cycleTime entry of the associated patternTable entry is
               zero (i.e. the device is in Free Mode), then the value of this
               object shall be applied, if non-zero, as a maximum time for the
               associated phase.

               If the critical path through the phase diagram is less than the
               cycleTime entry of the associated patternTable entry, all extra
               time is allotted to the coordination phase in each ring.

               If the critical path through the phase diagram is greater than
               the cycleTime entry of the associated patternTable entry (and the
               cycleTime is not zero) the device shall operate in the Free Mode.

            While the Free Mode condition exists, the Local Override bit of
            shortAlarm shall be set to one (1).
      <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.4.9.1.3
      <Unit> second"
      REFERENCE "NEMA TS 2 Clause 3.6.2.1.2"
::= { splitEntry 3 }

splitTime · optional

splitTime   OBJECT-TYPE
   SYNTAX   INTEGER (0..255)
   ACCESS   read-write
   STATUS   optional
   DESCRIPTION
      "<Definition> The time in seconds the splitPhase is
       allowed to receive (i.e. before a Force Off is
       applied) when constant demands exist on all phases.
       In floating coordForceMode, this is always the
       maximum time a non-coordinated phase is allowed to
       receive. In fixed coordForceMode, the actual allowed
       time may be longer if a previous phase gapped out.

          The splitTime includes all phase clearance times for
          the associated phase. The split time shall be longer
          than the sum of the phase minimum service
          requirements for the phase. When the time is NOT
          adequate to service the minimum service requirements
          of the phase, Free Mode shall be the result. The
          minimum requirements of a phase with a not-actuated
          ped include Minimum Green, Walk, Pedestrian Clear,
          Yellow Clearance, and Red Clearance; the minimum



                                                                                      

                                                                                      
                                                                                     

        requirements of a phase with an actuated pedestrian
        include Minimum Green, Yellow Clearance, and Red
        Clearance.

        If the cycleTime entry of the associated
        patternTable entry is zero (i.e. the device is in
        Free Mode), then the value of this object shall be
        applied, if non-zero, as a maximum time for the
        associated phase.

        If the critical path through the phase diagram is
        less than the cycleTime entry of the associated
        patternTable entry, all extra time is alloted to the
        coordination phase in each ring.

        If the critical path through the phase diagram is
        greater than the cycleTime entry of the associated
        patternTable entry (and the cycleTime is not zero)
        the device shall operate in the Free Mode.

       While the Free Mode condition exists, the Local
       Override bit of shortAlarm shall be set to one (1).
       <DescriptiveName> NTCIP-1202::ASC.splitTime
       <DataConceptType> Data Element
       <Unit> second"
   REFERENCE
      "NEMA TS 2 Clause 3.6.2.1.2"
::= { splitEntry 3 }

splitTime · mandatory

splitTime   OBJECT-TYPE
      SYNTAX INTEGER (0..255)
      ACCESS read-write
      STATUS mandatory
      DESCRIPTION "<Definition> The time in seconds the splitPhase is allowed
            to receive (i.e. before a Force Off is applied) when constant
            demands exist on all phases. In floating coordForceMode, this is
            always the maximum time a non-coordinated phase is allowed to
            receive. In fixed coordForceMode, the actual allowed time may be
            longer if a previous phase gapped out.

                 The splitTime includes all phase clearance times for the
                 associated phase. The split time shall be longer than the sum of
                 the phase minimum service requirements for the phase. When the
                 time is NOT adequate to service the minimum service requirements
                 of the phase, Free Mode shall be the result. The minimum
                 requirements of a phase with a not-actuated ped include Minimum
                 Green, Walk, Pedestrian Clear, Yellow Clearance, and Red
                 Clearance; the minimum requirements of a phase with an actuated
                 pedestrian include Minimum Green, Yellow Clearance, and Red
                 Clearance.

                 If the cycleTime entry of the associated patternTable entry is
                 zero (i.e. the device is in Free Mode), then the value of this
                 object shall be applied, if non-zero, as a maximum time for the
                 associated phase.

                 If the critical path through the phase diagram is less than the
                 cycleTime entry of the associated patternTable entry, all extra
                 time is allotted to the coordination phase in each ring.

                 If the critical path through the phase diagram is greater than
                 the cycleTime entry of the associated patternTable entry (and the
                 cycleTime is not zero) the device shall operate in the Free Mode.

                 While the Free Mode condition exists, the Local Override bit of
                 shortAlarm shall be set to one (1).


                                                                                        

                                                                                   
                                                                                  

      <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.4.9.1.3
      <Object Type> P
      <Unit> second"
      REFERENCE "NEMA TS 2 Clause 3.6.2.1.2"
::= { splitEntry 3 }

Meaning

Descriptions

4 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

The time in seconds the splitPhase is allowed to receive (i.e. before a Force Off is applied) when constant demands exist on all phases. In floating coordForceMode, this is always the maximum time a non-coordinated phase is allowed to receive. In fixed coordForceMode, the actual allowed time may be longer if a previous phase gapped out. The splitTime includes all phase clearance times for the associated phase. The split time shall be longer than the sum of the phase minimum service requirements (Minimum Green, Yellow Change, Red Clearance, Walk, Pedestrian Clearance, etc.) for the phase. When the time is NOT adequate to service the minimum service requirements of the phase, Free Mode shall be the result. If the cycleTime entry of the associated patternTable entry is zero (i.e. the device is in Free Mode), then the value of this object shall be applied as a maximum time for the associated phase. If the critical path through the phase diagram is less than the cycleTime entry of the associated patternTable entry, all extra time is allotted to the coordination phase in each ring. If the critical path through the phase diagram is greater than the cycleTime entry of the associated patternTable entry (and the cycleTime is not zero) the device shall operate in the Free Mode. TS 3.5-1996 While the Free Mode condition exists, the Local Override bit of shortAlarm shall be set to one (1).

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 2

<Definition> The time in seconds the splitPhase is allowed to receive (i.e. before a Force Off is applied) when constant demands exist on all phases. In floating coordForceMode, this is always the maximum time a non-coordinated phase is allowed to receive. In fixed coordForceMode, the actual allowed time may be longer if a previous phase gapped out. The splitTime includes all phase clearance times for the associated phase. The split time shall be longer than the sum of the phase minimum service requirements for the phase. When the time is NOT adequate to service the minimum service requirements of the phase, Free Mode shall be the result. The minimum requirements of a phase with a not-actuated ped include Minimum Green, Walk, Pedestrian Clear, Yellow Clearance, and Red Clearance; the minimum requirements of a phase with an actuated pedestrian include Minimum Green, Yellow Clearance, and Red Clearance. If the cycleTime entry of the associated patternTable entry is zero (i.e. the device is in Free Mode), then the value of this object shall be applied, if non-zero, as a maximum time for the associated phase. If the critical path through the phase diagram is less than the cycleTime entry of the associated patternTable entry, all extra time is allotted to the coordination phase in each ring. If the critical path through the phase diagram is greater than the cycleTime entry of the associated patternTable entry (and the cycleTime is not zero) the device shall operate in the Free Mode. While the Free Mode condition exists, the Local Override bit of shortAlarm shall be set to one (1). <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.4.9.1.3 <Unit> second

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 3

<Definition> The time in seconds the splitPhase is allowed to receive (i.e. before a Force Off is applied) when constant demands exist on all phases. In floating coordForceMode, this is always the maximum time a non-coordinated phase is allowed to receive. In fixed coordForceMode, the actual allowed time may be longer if a previous phase gapped out. The splitTime includes all phase clearance times for the associated phase. The split time shall be longer than the sum of the phase minimum service requirements for the phase. When the time is NOT adequate to service the minimum service requirements of the phase, Free Mode shall be the result. The minimum requirements of a phase with a not-actuated ped include Minimum Green, Walk, Pedestrian Clear, Yellow Clearance, and Red Clearance; the minimum requirements of a phase with an actuated pedestrian include Minimum Green, Yellow Clearance, and Red Clearance. If the cycleTime entry of the associated patternTable entry is zero (i.e. the device is in Free Mode), then the value of this object shall be applied, if non-zero, as a maximum time for the associated phase. If the critical path through the phase diagram is less than the cycleTime entry of the associated patternTable entry, all extra time is alloted to the coordination phase in each ring. If the critical path through the phase diagram is greater than the cycleTime entry of the associated patternTable entry (and the cycleTime is not zero) the device shall operate in the Free Mode. While the Free Mode condition exists, the Local Override bit of shortAlarm shall be set to one (1). <DescriptiveName> NTCIP-1202::ASC.splitTime <DataConceptType> Data Element <Unit> second

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 4

<Definition> The time in seconds the splitPhase is allowed to receive (i.e. before a Force Off is applied) when constant demands exist on all phases. In floating coordForceMode, this is always the maximum time a non-coordinated phase is allowed to receive. In fixed coordForceMode, the actual allowed time may be longer if a previous phase gapped out. The splitTime includes all phase clearance times for the associated phase. The split time shall be longer than the sum of the phase minimum service requirements for the phase. When the time is NOT adequate to service the minimum service requirements of the phase, Free Mode shall be the result. The minimum requirements of a phase with a not-actuated ped include Minimum Green, Walk, Pedestrian Clear, Yellow Clearance, and Red Clearance; the minimum requirements of a phase with an actuated pedestrian include Minimum Green, Yellow Clearance, and Red Clearance. If the cycleTime entry of the associated patternTable entry is zero (i.e. the device is in Free Mode), then the value of this object shall be applied, if non-zero, as a maximum time for the associated phase. If the critical path through the phase diagram is less than the cycleTime entry of the associated patternTable entry, all extra time is allotted to the coordination phase in each ring. If the critical path through the phase diagram is greater than the cycleTime entry of the associated patternTable entry (and the cycleTime is not zero) the device shall operate in the Free Mode. While the Free Mode condition exists, the Local Override bit of shortAlarm shall be set to one (1). <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.4.9.1.3 <Object Type> P <Unit> second

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

4 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 1

splitTime · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: splitTime

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "splitTime",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "255",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"The time in seconds the splitPhase is allowed to receive (i.e. before a Force Off is applied) when constant demands exist on all phases. In floating coordForceMode, this is always the maximum time a non-coordinated phase is allowed to receive. In fixed coordForceMode, the actual allowed time may be longer if a previous phase gapped out. The splitTime includes all phase clearance times for the associated phase. The split time shall be longer than the sum of the phase minimum service requirements (Minimum Green, Yellow Change, Red Clearance, Walk, Pedestrian Clearance, etc.) for the phase. When the time is NOT adequate to service the minimum service requirements of the phase, Free Mode shall be the result. If the cycleTime entry of the associated patternTable entry is zero (i.e. the device is in Free Mode), then the value of this object shall be applied as a maximum time for the associated phase. If the critical path through the phase diagram is less than the cycleTime entry of the associated patternTable entry, all extra time is allotted to the coordination phase in each ring. If the critical path through the phase diagram is greater than the cycleTime entry of the associated patternTable entry (and the cycleTime is not zero) the device shall operate in the Free Mode. TS 3.5-1996 While the Free Mode condition exists, the Local Override bit of shortAlarm shall be set to one (1).\"",
    "REFERENCE",
    "\"NEMA TS 2 Clause 3.6.2.1.2\"",
    "::=",
    "{",
    "splitEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "The time in seconds the splitPhase is allowed to receive (i.e. before a Force Off is applied) when constant demands exist on all phases. In floating coordForceMode, this is always the maximum time a non-coordinated phase is allowed to receive. In fixed coordForceMode, the actual allowed time may be longer if a previous phase gapped out. The splitTime includes all phase clearance times for the associated phase. The split time shall be longer than the sum of the phase minimum service requirements (Minimum Green, Yellow Change, Red Clearance, Walk, Pedestrian Clearance, etc.) for the phase. When the time is NOT adequate to service the minimum service requirements of the phase, Free Mode shall be the result. If the cycleTime entry of the associated patternTable entry is zero (i.e. the device is in Free Mode), then the value of this object shall be applied as a maximum time for the associated phase. If the critical path through the phase diagram is less than the cycleTime entry of the associated patternTable entry, all extra time is allotted to the coordination phase in each ring. If the critical path through the phase diagram is greater than the cycleTime entry of the associated patternTable entry (and the cycleTime is not zero) the device shall operate in the Free Mode. TS 3.5-1996 While the Free Mode condition exists, the Local Override bit of shortAlarm shall be set to one (1)."
    ],
    [
      "REFERENCE",
      "NEMA TS 2 Clause 3.6.2.1.2"
    ],
    null,
    null,
    null
  ]
}
Records for description 2NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 2

splitTime · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: splitTime

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "splitTime",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "255",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> The time in seconds the splitPhase is allowed to receive (i.e. before a Force Off is applied) when constant demands exist on all phases. In floating coordForceMode, this is always the maximum time a non-coordinated phase is allowed to receive. In fixed coordForceMode, the actual allowed time may be longer if a previous phase gapped out. The splitTime includes all phase clearance times for the associated phase. The split time shall be longer than the sum of the phase minimum service requirements for the phase. When the time is NOT adequate to service the minimum service requirements of the phase, Free Mode shall be the result. The minimum requirements of a phase with a not-actuated ped include Minimum Green, Walk, Pedestrian Clear, Yellow Clearance, and Red Clearance; the minimum requirements of a phase with an actuated pedestrian include Minimum Green, Yellow Clearance, and Red Clearance. If the cycleTime entry of the associated patternTable entry is zero (i.e. the device is in Free Mode), then the value of this object shall be applied, if non-zero, as a maximum time for the associated phase. If the critical path through the phase diagram is less than the cycleTime entry of the associated patternTable entry, all extra time is allotted to the coordination phase in each ring. If the critical path through the phase diagram is greater than the cycleTime entry of the associated patternTable entry (and the cycleTime is not zero) the device shall operate in the Free Mode. While the Free Mode condition exists, the Local Override bit of shortAlarm shall be set to one (1). <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.4.9.1.3 <Unit> second\"",
    "REFERENCE",
    "\"NEMA TS 2 Clause 3.6.2.1.2\"",
    "::=",
    "{",
    "splitEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> The time in seconds the splitPhase is allowed to receive (i.e. before a Force Off is applied) when constant demands exist on all phases. In floating coordForceMode, this is always the maximum time a non-coordinated phase is allowed to receive. In fixed coordForceMode, the actual allowed time may be longer if a previous phase gapped out. The splitTime includes all phase clearance times for the associated phase. The split time shall be longer than the sum of the phase minimum service requirements for the phase. When the time is NOT adequate to service the minimum service requirements of the phase, Free Mode shall be the result. The minimum requirements of a phase with a not-actuated ped include Minimum Green, Walk, Pedestrian Clear, Yellow Clearance, and Red Clearance; the minimum requirements of a phase with an actuated pedestrian include Minimum Green, Yellow Clearance, and Red Clearance. If the cycleTime entry of the associated patternTable entry is zero (i.e. the device is in Free Mode), then the value of this object shall be applied, if non-zero, as a maximum time for the associated phase. If the critical path through the phase diagram is less than the cycleTime entry of the associated patternTable entry, all extra time is allotted to the coordination phase in each ring. If the critical path through the phase diagram is greater than the cycleTime entry of the associated patternTable entry (and the cycleTime is not zero) the device shall operate in the Free Mode. While the Free Mode condition exists, the Local Override bit of shortAlarm shall be set to one (1). <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.4.9.1.3 <Unit> second"
    ],
    [
      "REFERENCE",
      "NEMA TS 2 Clause 3.6.2.1.2"
    ],
    null,
    null,
    null
  ]
}
Records for description 3NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 3

splitTime · optionalNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: optional.

Names: splitTime

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "splitTime",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "255",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "optional",
    "DESCRIPTION",
    "\"<Definition> The time in seconds the splitPhase is allowed to receive (i.e. before a Force Off is applied) when constant demands exist on all phases. In floating coordForceMode, this is always the maximum time a non-coordinated phase is allowed to receive. In fixed coordForceMode, the actual allowed time may be longer if a previous phase gapped out. The splitTime includes all phase clearance times for the associated phase. The split time shall be longer than the sum of the phase minimum service requirements for the phase. When the time is NOT adequate to service the minimum service requirements of the phase, Free Mode shall be the result. The minimum requirements of a phase with a not-actuated ped include Minimum Green, Walk, Pedestrian Clear, Yellow Clearance, and Red Clearance; the minimum requirements of a phase with an actuated pedestrian include Minimum Green, Yellow Clearance, and Red Clearance. If the cycleTime entry of the associated patternTable entry is zero (i.e. the device is in Free Mode), then the value of this object shall be applied, if non-zero, as a maximum time for the associated phase. If the critical path through the phase diagram is less than the cycleTime entry of the associated patternTable entry, all extra time is alloted to the coordination phase in each ring. If the critical path through the phase diagram is greater than the cycleTime entry of the associated patternTable entry (and the cycleTime is not zero) the device shall operate in the Free Mode. While the Free Mode condition exists, the Local Override bit of shortAlarm shall be set to one (1). <DescriptiveName> NTCIP-1202::ASC.splitTime <DataConceptType> Data Element <Unit> second\"",
    "REFERENCE",
    "\"NEMA TS 2 Clause 3.6.2.1.2\"",
    "::=",
    "{",
    "splitEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "optional"
    ],
    [
      "DESCRIPTION",
      "<Definition> The time in seconds the splitPhase is allowed to receive (i.e. before a Force Off is applied) when constant demands exist on all phases. In floating coordForceMode, this is always the maximum time a non-coordinated phase is allowed to receive. In fixed coordForceMode, the actual allowed time may be longer if a previous phase gapped out. The splitTime includes all phase clearance times for the associated phase. The split time shall be longer than the sum of the phase minimum service requirements for the phase. When the time is NOT adequate to service the minimum service requirements of the phase, Free Mode shall be the result. The minimum requirements of a phase with a not-actuated ped include Minimum Green, Walk, Pedestrian Clear, Yellow Clearance, and Red Clearance; the minimum requirements of a phase with an actuated pedestrian include Minimum Green, Yellow Clearance, and Red Clearance. If the cycleTime entry of the associated patternTable entry is zero (i.e. the device is in Free Mode), then the value of this object shall be applied, if non-zero, as a maximum time for the associated phase. If the critical path through the phase diagram is less than the cycleTime entry of the associated patternTable entry, all extra time is alloted to the coordination phase in each ring. If the critical path through the phase diagram is greater than the cycleTime entry of the associated patternTable entry (and the cycleTime is not zero) the device shall operate in the Free Mode. While the Free Mode condition exists, the Local Override bit of shortAlarm shall be set to one (1). <DescriptiveName> NTCIP-1202::ASC.splitTime <DataConceptType> Data Element <Unit> second"
    ],
    [
      "REFERENCE",
      "NEMA TS 2 Clause 3.6.2.1.2"
    ],
    null,
    null,
    null
  ]
}
Records for description 4NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 4

splitTime · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: splitTime

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "splitTime",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "255",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> The time in seconds the splitPhase is allowed to receive (i.e. before a Force Off is applied) when constant demands exist on all phases. In floating coordForceMode, this is always the maximum time a non-coordinated phase is allowed to receive. In fixed coordForceMode, the actual allowed time may be longer if a previous phase gapped out. The splitTime includes all phase clearance times for the associated phase. The split time shall be longer than the sum of the phase minimum service requirements for the phase. When the time is NOT adequate to service the minimum service requirements of the phase, Free Mode shall be the result. The minimum requirements of a phase with a not-actuated ped include Minimum Green, Walk, Pedestrian Clear, Yellow Clearance, and Red Clearance; the minimum requirements of a phase with an actuated pedestrian include Minimum Green, Yellow Clearance, and Red Clearance. If the cycleTime entry of the associated patternTable entry is zero (i.e. the device is in Free Mode), then the value of this object shall be applied, if non-zero, as a maximum time for the associated phase. If the critical path through the phase diagram is less than the cycleTime entry of the associated patternTable entry, all extra time is allotted to the coordination phase in each ring. If the critical path through the phase diagram is greater than the cycleTime entry of the associated patternTable entry (and the cycleTime is not zero) the device shall operate in the Free Mode. While the Free Mode condition exists, the Local Override bit of shortAlarm shall be set to one (1). <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.4.9.1.3 <Object Type> P <Unit> second\"",
    "REFERENCE",
    "\"NEMA TS 2 Clause 3.6.2.1.2\"",
    "::=",
    "{",
    "splitEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> The time in seconds the splitPhase is allowed to receive (i.e. before a Force Off is applied) when constant demands exist on all phases. In floating coordForceMode, this is always the maximum time a non-coordinated phase is allowed to receive. In fixed coordForceMode, the actual allowed time may be longer if a previous phase gapped out. The splitTime includes all phase clearance times for the associated phase. The split time shall be longer than the sum of the phase minimum service requirements for the phase. When the time is NOT adequate to service the minimum service requirements of the phase, Free Mode shall be the result. The minimum requirements of a phase with a not-actuated ped include Minimum Green, Walk, Pedestrian Clear, Yellow Clearance, and Red Clearance; the minimum requirements of a phase with an actuated pedestrian include Minimum Green, Yellow Clearance, and Red Clearance. If the cycleTime entry of the associated patternTable entry is zero (i.e. the device is in Free Mode), then the value of this object shall be applied, if non-zero, as a maximum time for the associated phase. If the critical path through the phase diagram is less than the cycleTime entry of the associated patternTable entry, all extra time is allotted to the coordination phase in each ring. If the critical path through the phase diagram is greater than the cycleTime entry of the associated patternTable entry (and the cycleTime is not zero) the device shall operate in the Free Mode. While the Free Mode condition exists, the Local Override bit of shortAlarm shall be set to one (1). <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.4.9.1.3 <Object Type> P <Unit> second"
    ],
    [
      "REFERENCE",
      "NEMA TS 2 Clause 3.6.2.1.2"
    ],
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (5)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.1.4.9.1.1 splitNumber00
1.3.6.1.4.1.1206.4.2.1.4.9.1.2 splitPhase00
1.3.6.1.4.1.1206.4.2.1.4.9.1.4 splitMode00
1.3.6.1.4.1.1206.4.2.1.4.9.1.5 splitCoordPhase00
1.3.6.1.4.1.1206.4.2.1.4.9.1.6 splitOptions00