OID reference

dmsOtherShortErrorDescr

1.3.6.1.4.1.1206.4.2.3.9.7.1

Description

<Definition> A bitmap of summary errors. When a bit is set, the error is presently active. When a bit is clear the error is not currently active. If no sensor is present or supported (for a corresponding bit), the bit shall not be set. The bits are defined as follows: <Format> Bit 0 - reserved -- The definition contai…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.3.9.7 (statError)
Node code
1
Node names
  • dmsOtherShortErrorDescr
  • shortErrorStatus
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.3.9.7.1
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.3.9.7.1
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 3 9 7 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(3) dmsStatus(9) statError(7) dmsOtherShortErrorDescr(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(3) dmsStatus(9) statError(7) shortErrorStatus(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) fontDefinition(3) dmsStatus(9) statError(7) dmsOtherShortErrorDescr(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) fontDefinition(3) dmsStatus(9) statError(7) shortErrorStatus(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(3) dmsStatus(9) statError(7) dmsOtherShortErrorDescr(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(3) dmsStatus(9) statError(7) shortErrorStatus(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) fontDefinition(3) dmsStatus(9) statError(7) dmsOtherShortErrorDescr(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) fontDefinition(3) dmsStatus(9) statError(7) shortErrorStatus(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) dms(3) dmsStatus(9) statError(7) dmsOtherShortErrorDescr(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) dms(3) dmsStatus(9) statError(7) shortErrorStatus(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) fontDefinition(3) dmsStatus(9) statError(7) dmsOtherShortErrorDescr(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) fontDefinition(3) dmsStatus(9) statError(7) shortErrorStatus(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) dms(3) dmsStatus(9) statError(7) dmsOtherShortErrorDescr(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) dms(3) dmsStatus(9) statError(7) shortErrorStatus(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) fontDefinition(3) dmsStatus(9) statError(7) dmsOtherShortErrorDescr(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) fontDefinition(3) dmsStatus(9) statError(7) shortErrorStatus(1)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/3/9/7/1
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/3/9/7/1
  • /ISO/3/6/1/4/1/1206/4/2/3/9/7/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/dmsStatus/statError/dmsOtherShortErrorDescr
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/dmsStatus/statError/shortErrorStatus
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/fontDefinition/dmsStatus/statError/dmsOtherShortErrorDescr
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/fontDefinition/dmsStatus/statError/shortErrorStatus
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/dmsStatus/statError/dmsOtherShortErrorDescr
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/dmsStatus/statError/shortErrorStatus
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/fontDefinition/dmsStatus/statError/dmsOtherShortErrorDescr
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/fontDefinition/dmsStatus/statError/shortErrorStatus
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/dms/dmsStatus/statError/dmsOtherShortErrorDescr
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/dms/dmsStatus/statError/shortErrorStatus
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/fontDefinition/dmsStatus/statError/dmsOtherShortErrorDescr
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/fontDefinition/dmsStatus/statError/shortErrorStatus
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/dms/dmsStatus/statError/dmsOtherShortErrorDescr
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/dms/dmsStatus/statError/shortErrorStatus
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/fontDefinition/dmsStatus/statError/dmsOtherShortErrorDescr
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/fontDefinition/dmsStatus/statError/shortErrorStatus
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER, SnmpAdminString, NtcipIntegerBitmap16
Maximum access defined by MIB
read-only
Status in MIB
mandatory, current

Definitions may combine these properties differently.

Compare 3 source variants

Variant 1 — NTCIP published standard MIB annexes (reviewed modules), ITE public NTCIP working repository MIBs

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
mandatory
Allowed ranges
0–65535

Variant 2 — ITE public NTCIP working repository MIBs

Value type
SnmpAdminString
Maximum access defined by MIB
read-only
Status in MIB
current

Variant 3 — ITE public NTCIP working repository MIBs

Value type
NtcipIntegerBitmap16
Maximum access defined by MIB
read-only
Status in MIB
current

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 6 distinct definitions; some records may not include a definition.

Show 6 published definitions

shortErrorStatus · mandatory

shortErrorStatus OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"<Definition> A bitmap of summary errors. When a bit is set, the error is
presently active. When a bit is clear the error is not currently active. If
no sensor is present or supported (for a corresponding bit), the bit
shall not be set.
   The bits are defined as follows:
<Format>
Bit 0 - reserved
--      The definition contained in Version 1 stated 'other'. However,
--      'other' is no longer allowed as a value.
Bit 1- communications error - this bit shall be set if any error
        associated with the communications between the central
        computer and the device occurs.
Bit 2- power error - this bit shall be set if any error associated with the
        power supply to any component occurs (see the objects
        dmsPowerFailureStatusMap and lowFuelThreshold).
Bit 3- attached device error - this bit shall be set if any error
        associated with attached (supported, and enabled) external
        devices occurs.
Bit 4- lamp error - this bit shall be set if any errors associated with any
        lamp occurs (see the objects lampFailureStuckOn and
        lampFailureStuckOff). This bit will only be applicable to devices that
        support lamps such as fiber optic signs or front-illuminated
        reflective signs. This bit is not applicable to lamps or fluorescent
        lights illuminating the housing or cabinet.
Bit 5- pixel error - this bit shall be set if any errors associated with any



                                                                                         

Page 190                                                             NTCIP 1203 v02.35


      pixel occurs (see the objects pixelFailureTableNumRows for NTCIP 1203v1
      deployments, and pixelFailureTableNumRows, and/or
      dmsPixelFailureTestRows and dmsPixelFailureMessageRows for NTCIP 1203v2
      deployments.).
      This bit will only be applicable to devices
      that support illumination of individual pixels, but not to drum signs.
      Note that certain sign technologies such as flip disk only sign may
      not be able to determine pixel errors.
Bit 6- photocell error - this bit shall be set if any errors associated with
      the supported light sensors occurs (see the object
      dmsLightSensorStatusMap).
Bit 7- message error - this bit shall be set if any errors associated with
      activating and/or displaying a message occurs (see the object
      dmsActivateMsgError).
Bit 8- controller error - this bit shall be set if any errors associated
      with the controller occurs (see the controllerErrorStatus object)
Bit 9- temperature warning - this bit shall be set if any of the
      temperature values detected by the device exceed
      non-standardized temperature values (see the object
      tempSensorWarningMap). This bit is included to allow
      vendors or agencies to define vendor- or agency-specific
      threshold objects that indicate temperature changes that are of
      interest but not dangerous to the life-expectancy of the device
      (see also the 'critical temperature' bit)
Bit 10- climate-control system error - this bit shall be set if any errors
      associated with the climate control systems such as fans and/or
      heaters occurs (see the object dmsClimateCtrlStatusMap).
Bit 11- critical temperature error - this bit shall be set if the critical
      temperature as defined by the value of the critical temperature
      objects have been exceeded. (see the object
      dmsTempSensorHighCriticalTemperature
      and dmsTempSensorLowCriticalTemperature).
Bit 12- Drum-sign Rotor error - This bit shall be set if any errors
      associated with the rotor of a drum sign occurs.
Bit 13- This bit shall be set if any door to any DMS field component
      (cabinet or housing) is open(see the object
      dmsStatDoorOpen).
Bit 14- Humidity warning - This bit shall be set if any humidity sensor
      sensor is reporting a humidity warning (see the object
      dmsHumiditySensorStatusMap).

-- To track a history of transient error conditions utilize the event
-- logging table located in the Global Objects Definitions (NTCIP 1201).

<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1"
::= { statError 1 }

shortErrorStatus · mandatory

shortErrorStatus OBJECT-TYPE
SYNTAX             INTEGER (0..65535)
ACCESS             read-only
STATUS             mandatory
DESCRIPTION “A bitmap of summary errors where the bits are defined as follows:
Bit 0- other error
Bit 1- communications error
Bit 2- power error
Bit 3- attached device error
Bit 4- lamp error
Bit 5- pixel error
Bit 6- photocell error
Bit 7- message error
Bit 8- controller error
Bit 9- temperature warning
Bit 10- fan error



                                                                                                                  

               
         



If a bit is set to one (1), then the associated error is existing; if the bit is set to zero (0), then the
associated error is not existing.”
::= {statError 1}

dmsOtherShortErrorDescr · unconfirmed

dmsOtherShortErrorDescr  OBJECT-TYPE 
SYNTAX      SnmpAdminString  
MAX-ACCESS  read-only 
STATUS      current  
DESCRIPTION  
"<Definition> A textual description of the 'other' error causing Bit 0 of 
shortErrorStatus to be set. This shall be a zero-length string when Bit 0 of 
shortErrorStatus is not set. The language used for this text-based message 
shall be as defined by ISO26048-1-Controller:fdDefaultLanguage.
<Parameter Type> Status
<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1"
::= { statError 39 }

shortErrorStatus · unconfirmed

shortErrorStatus  OBJECT-TYPE 
SYNTAX      NtcipIntegerBitmap16  
MAX-ACCESS  read-only 
STATUS      current  
DESCRIPTION  
"<Definition> A bitmap of summary errors. When a bit is set, the error is 
presently active. When a bit is clear the error is not currently active. If 
no sensor is present or supported (for a corresponding bit), the bit 
shall not be set. 
<Format>  The bits are defined as follows:
Bit 0- other - not defined by this standard, see the value of 
      dmsOtherShortErrorDescr.
      The value of other was deprecated in v02 and reinstated in v04.
Bit 1- communications error - this bit shall be set if any error 
      associated with the communications between the central 
      computer and the device occurs.
Bit 2- power error - this bit shall be set if any error is detected for any 
      power supply associated with any component (i.e., any bit set in 
      fdSrsaTypeWarning.FPA, FPS, or FPV) or if the generator fuel 
      level is below its minimum threshold or has an error 
      (i.e., any bit set in fdSrsaTypeWarning.FGF). 
Bit 3- attached device error - this bit shall be set if any error 
      associated with attached (supported, and enabled) external 
      devices occurs (i.e., any bit set in any fdSrsaTypeWarning object 
      that is not otherwise specified by other bots of this object).
Bit 4- lamp error - this bit shall be set if any errors associated with any 
      lamp occurs (i.e., any bit set in fdSrsaTypeWarning.MLS) This bit 
      is only applicable to devices that support lamps such as fiber optic 
      signs or front-illuminated reflective signs. This bit is not applicable 
      to lamps or fluorescent lights illuminating the housing or cabinet.
Bit 5- pixel error - this bit shall be set if any errors associated with any 
      pixel occurs (see the objects pixelFailureTableNumRows for NTCIP 1203 
      v01 deployments, and pixelFailureTableNumRows, and/or 
      dmsPixelFailureTestRows and dmsPixelFailureMessageRows for NTCIP 1203
      v02 deployments.). 
      This bit is only applicable to devices that support illumination of 
      individual pixels, but not to drum signs. 
      Note that certain sign technologies such as flip disk only sign may 
      not be able to determine pixel errors.
Bit 6- photocell error - this bit shall be set if any errors associated with 
      the supported light sensors occurs (i.e., any bit set in 
      fdSrsaTypeWarning.FAL). 
Bit 7- message error - this bit shall be set if any errors associated with 
      activating and/or displaying a message occurs (see the object
      dmsActivateMsgError).
Bit 8- controller error - this bit shall be set if any errors associated 
      with the controller occurs (i.e., any bit set in fdControllerStatus). 
Bit 9- temperature warning - this bit shall be set if any of the 
      temperature values detected by the device exceed 
      non-standardized temperature values (i.e., any bit set in 
      fdSrsaTypeWarning.FAT FET, or FPT). This bit is included to allow 
      vendors or agencies to define vendor- or agency-specific 
      threshold objects that indicate temperature changes that are of 
      interest but not dangerous to the life-expectancy of the device 
      (see also the 'critical temperature' bit)
Bit 10- climate-control system error - this bit shall be set if any errors 
      associated with the climate control systems such as fans and/or 
      heaters occurs (i.e., any bit set in fdSrsaTypeWarning.FAC, FDC, 
      FFO, FHO, or FTT).
Bit 11- critical temperature error - this bit shall be set if the critical 
      temperature as defined by the value of the critical temperature
      objects have been exceeded (i.e., any bit set in 
      fdSrsaTypeStatus.FAT, FET, or FPT).
Bit 12- Drum-sign Rotor error - This bit shall be set if any errors 
      associated with the rotor of a drum sign occurs (i.e., any bit set in
      fdSrsaTypeWarning.MDS).
Bit 13- This bit shall be set if any door to any DMS field component 
      (cabinet or housing) is open (i.e., any bit set in 
      fdSrsaTypeWarning.FDO).
Bit 14- Humidity warning - This bit shall be set if any humidity sensor
      sensor is reporting a humidity warning (i.e., any bit set in 
      fdSrsaTypeWarning.FAH or FEH).
Bit 15- invisible default text - this bit shall be set if the value for 
defaultBackgroudRGB is equal to the value of defaultForegroundRGB, which 
would result in the message not being visible unless the MULTI string itself 
specifies alternate colors. 

<Informative> To track a history of transient error conditions utilize the 
event logging table located in the Global Objects Definitions (NTCIP 1201).
<Parameter Type> Status
<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1"
::= { statError 1 }

shortErrorStatus · mandatory

shortErrorStatus  OBJECT-TYPE
SYNTAX  INTEGER (0..65535)
ACCESS  read-only
STATUS  mandatory
DESCRIPTION 
"<Definition> A bitmap of summary errors. When a bit is set, the error is presently active. When a bit is clear the error is not currently active. If no sensor is present or supported (for a corresponding bit), the bit 
shall not be set. 
  The bits are defined as follows:
<Format>
Bit 0 - reserved 
--    The definition contained in Version 1 stated 'other'. However,
--    'other' is no longer allowed as a value.
Bit 1- communications error - this bit shall be set if any error 
      associated with the communications between the central 
      computer and the device occurs.
Bit 2- power error - this bit shall be set if any error associated with the 
      power supply to any component occurs (see the objects 
      dmsPowerFailureStatusMap and lowFuelThreshold).
Bit 3- attached device error - this bit shall be set if any error 
      associated with attached (supported, and enabled) external 
      devices occurs.
Bit 4- lamp error - this bit shall be set if any errors associated with any 
      lamp occurs (see the objects lampFailureStuckOn and
      lampFailureStuckOff). This bit is only applicable to devices that 
      support lamps such as fiber optic signs or front-illuminated 
      reflective signs. This bit is not applicable to lamps or fluorescent 
      lights illuminating the housing or cabinet.
Bit 5- pixel error - this bit shall be set if any errors associated with any 
      pixel occurs (see the objects pixelFailureTableNumRows for NTCIP 1203v1
      deployments, and pixelFailureTableNumRows, and/or
      dmsPixelFailureTestRows and dmsPixelFailureMessageRows for NTCIP 1203v2
      deployments.). 
      This bit is only applicable to devices 
      that support illumination of individual pixels, but not to drum signs. 
      Note that certain sign technologies such as flip disk only sign may 
      not be able to determine pixel errors.
Bit 6- photocell error - this bit shall be set if any errors associated with 
      the supported light sensors occurs (see the object
      dmsLightSensorStatusMap).
Bit 7- message error - this bit shall be set if any errors associated with 
      activating and/or displaying a message occurs (see the object
      dmsActivateMsgError).
Bit 8- controller error - this bit shall be set if any errors associated 
      with the controller occurs (see the controllerErrorStatus object)
Bit 9- temperature warning - this bit shall be set if any of the 
      temperature values detected by the device exceed 
      non-standardized temperature values (see the object
      tempSensorWarningMap). This bit is included to allow 
      vendors or agencies to define vendor- or agency-specific 
      threshold objects that indicate temperature changes that are of 
      interest but not dangerous to the life-expectancy of the device 
      (see also the 'critical temperature' bit)
Bit 10- climate-control system error - this bit shall be set if any errors 
      associated with the climate control systems such as fans and/or 
      heaters occurs (see the object dmsClimateCtrlStatusMap).
Bit 11- critical temperature error - this bit shall be set if the critical 
      temperature as defined by the value of the critical temperature
      objects have been exceeded. (see the object 
      dmsTempSensorHighCriticalTemperature 
      and dmsTempSensorLowCriticalTemperature).
Bit 12- Drum-sign Rotor error - This bit shall be set if any errors 
      associated with the rotor of a drum sign occurs.
Bit 13- This bit shall be set if any door to any DMS field component 
      (cabinet or housing) is open(see the object 
      dmsStatDoorOpen).
Bit 14- Humidity warning - This bit shall be set if any humidity sensor
      sensor is reporting a humidity warning (see the object 
      dmsHumiditySensorStatusMap).

-- To track a history of transient error conditions utilize the event 
-- logging table located in the Global Objects Definitions (NTCIP 1201).

<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1"
::= { statError 1 }

shortErrorStatus · mandatory

shortErrorStatus OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"<Definition> A bitmap of summary errors. When a bit is set, the error is
presently active. When a bit is clear the error is not currently active. If
no sensor is present or supported (for a corresponding bit), the bit
shall not be set.
   The bits are defined as follows:
<Format>
Bit 0 - reserved
--      The definition contained in Version 1 stated 'other'. However,
--      'other' is no longer allowed as a value.
Bit 1- communications error - this bit shall be set if any error
        associated with the communications between the central
        computer and the device occurs.


                                                                                   

                                                                               
                                                                              

Bit 2- power error - this bit shall be set if any error associated with the
      power supply to any component occurs (see the objects
      dmsPowerFailureStatusMap and lowFuelThreshold).
Bit 3- attached device error - this bit shall be set if any error
      associated with attached (supported, and enabled) external
      devices occurs.
Bit 4- lamp error - this bit shall be set if any errors associated with any
      lamp occurs (see the objects lampFailureStuckOn and
      lampFailureStuckOff). This bit is only applicable to devices that
      support lamps such as fiber optic signs or front-illuminated
      reflective signs. This bit is not applicable to lamps or fluorescent
      lights illuminating the housing or cabinet.
Bit 5- pixel error - this bit shall be set if any errors associated with any
      pixel occurs (see the objects pixelFailureTableNumRows for NTCIP 1203v1
      deployments, and pixelFailureTableNumRows, and/or
      dmsPixelFailureTestRows and dmsPixelFailureMessageRows for NTCIP 1203v2
      deployments.).
      This bit is only applicable to devices
      that support illumination of individual pixels, but not to drum signs.
      Note that certain sign technologies such as flip disk only sign may
      not be able to determine pixel errors.
Bit 6- photocell error - this bit shall be set if any errors associated with
      the supported light sensors occurs (see the object
      dmsLightSensorStatusMap).
Bit 7- message error - this bit shall be set if any errors associated with
      activating and/or displaying a message occurs (see the object
      dmsActivateMsgError).
Bit 8- controller error - this bit shall be set if any errors associated
      with the controller occurs (see the controllerErrorStatus object)
Bit 9- temperature warning - this bit shall be set if any of the
      temperature values detected by the device exceed
      non-standardized temperature values (see the object
      tempSensorWarningMap). This bit is included to allow
      vendors or agencies to define vendor- or agency-specific
      threshold objects that indicate temperature changes that are of
      interest but not dangerous to the life-expectancy of the device
      (see also the 'critical temperature' bit)
Bit 10- climate-control system error - this bit shall be set if any errors
      associated with the climate control systems such as fans and/or
      heaters occurs (see the object dmsClimateCtrlStatusMap).
Bit 11- critical temperature error - this bit shall be set if the critical
      temperature as defined by the value of the critical temperature
      objects have been exceeded. (see the object
      dmsTempSensorHighCriticalTemperature
      and dmsTempSensorLowCriticalTemperature).
Bit 12- Drum-sign Rotor error - This bit shall be set if any errors
      associated with the rotor of a drum sign occurs.
Bit 13- This bit shall be set if any door to any DMS field component
      (cabinet or housing) is open(see the object
      dmsStatDoorOpen).
Bit 14- Humidity warning - This bit shall be set if any humidity sensor
      sensor is reporting a humidity warning (see the object
      dmsHumiditySensorStatusMap).

-- To track a history of transient error conditions utilize the event
-- logging table located in the Global Objects Definitions (NTCIP 1201).




                                                                                        

                 
        

<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1"
::= { statError 1 }

Meaning

Descriptions

5 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

<Definition> A bitmap of summary errors. When a bit is set, the error is presently active. When a bit is clear the error is not currently active. If no sensor is present or supported (for a corresponding bit), the bit shall not be set. The bits are defined as follows: <Format> Bit 0 - reserved -- The definition contained in Version 1 stated 'other'. However, -- 'other' is no longer allowed as a value. Bit 1- communications error - this bit shall be set if any error associated with the communications between the central computer and the device occurs. Bit 2- power error - this bit shall be set if any error associated with the power supply to any component occurs (see the objects dmsPowerFailureStatusMap and lowFuelThreshold). Bit 3- attached device error - this bit shall be set if any error associated with attached (supported, and enabled) external devices occurs. Bit 4- lamp error - this bit shall be set if any errors associated with any lamp occurs (see the objects lampFailureStuckOn and lampFailureStuckOff). This bit will only be applicable to devices that support lamps such as fiber optic signs or front-illuminated reflective signs. This bit is not applicable to lamps or fluorescent lights illuminating the housing or cabinet. Bit 5- pixel error - this bit shall be set if any errors associated with any Page 190 NTCIP 1203 v02.35 pixel occurs (see the objects pixelFailureTableNumRows for NTCIP 1203v1 deployments, and pixelFailureTableNumRows, and/or dmsPixelFailureTestRows and dmsPixelFailureMessageRows for NTCIP 1203v2 deployments.). This bit will only be applicable to devices that support illumination of individual pixels, but not to drum signs. Note that certain sign technologies such as flip disk only sign may not be able to determine pixel errors. Bit 6- photocell error - this bit shall be set if any errors associated with the supported light sensors occurs (see the object dmsLightSensorStatusMap). Bit 7- message error - this bit shall be set if any errors associated with activating and/or displaying a message occurs (see the object dmsActivateMsgError). Bit 8- controller error - this bit shall be set if any errors associated with the controller occurs (see the controllerErrorStatus object) Bit 9- temperature warning - this bit shall be set if any of the temperature values detected by the device exceed non-standardized temperature values (see the object tempSensorWarningMap). This bit is included to allow vendors or agencies to define vendor- or agency-specific threshold objects that indicate temperature changes that are of interest but not dangerous to the life-expectancy of the device (see also the 'critical temperature' bit) Bit 10- climate-control system error - this bit shall be set if any errors associated with the climate control systems such as fans and/or heaters occurs (see the object dmsClimateCtrlStatusMap). Bit 11- critical temperature error - this bit shall be set if the critical temperature as defined by the value of the critical temperature objects have been exceeded. (see the object dmsTempSensorHighCriticalTemperature and dmsTempSensorLowCriticalTemperature). Bit 12- Drum-sign Rotor error - This bit shall be set if any errors associated with the rotor of a drum sign occurs. Bit 13- This bit shall be set if any door to any DMS field component (cabinet or housing) is open(see the object dmsStatDoorOpen). Bit 14- Humidity warning - This bit shall be set if any humidity sensor sensor is reporting a humidity warning (see the object dmsHumiditySensorStatusMap). -- To track a history of transient error conditions utilize the event -- logging table located in the Global Objects Definitions (NTCIP 1201). <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 2

A bitmap of summary errors where the bits are defined as follows: Bit 0- other error Bit 1- communications error Bit 2- power error Bit 3- attached device error Bit 4- lamp error Bit 5- pixel error Bit 6- photocell error Bit 7- message error Bit 8- controller error Bit 9- temperature warning Bit 10- fan error If a bit is set to one (1), then the associated error is existing; if the bit is set to zero (0), then the associated error is not existing.

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 3

<Definition> A textual description of the 'other' error causing Bit 0 of shortErrorStatus to be set. This shall be a zero-length string when Bit 0 of shortErrorStatus is not set. The language used for this text-based message shall be as defined by ISO26048-1-Controller:fdDefaultLanguage. <Parameter Type> Status <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1

Sources for this description

ITE public NTCIP working repository MIBs

See 1 matching source record

Description 4

<Definition> A bitmap of summary errors. When a bit is set, the error is presently active. When a bit is clear the error is not currently active. If no sensor is present or supported (for a corresponding bit), the bit shall not be set. <Format> The bits are defined as follows: Bit 0- other - not defined by this standard, see the value of dmsOtherShortErrorDescr. The value of other was deprecated in v02 and reinstated in v04. Bit 1- communications error - this bit shall be set if any error associated with the communications between the central computer and the device occurs. Bit 2- power error - this bit shall be set if any error is detected for any power supply associated with any component (i.e., any bit set in fdSrsaTypeWarning.FPA, FPS, or FPV) or if the generator fuel level is below its minimum threshold or has an error (i.e., any bit set in fdSrsaTypeWarning.FGF). Bit 3- attached device error - this bit shall be set if any error associated with attached (supported, and enabled) external devices occurs (i.e., any bit set in any fdSrsaTypeWarning object that is not otherwise specified by other bots of this object). Bit 4- lamp error - this bit shall be set if any errors associated with any lamp occurs (i.e., any bit set in fdSrsaTypeWarning.MLS) This bit is only applicable to devices that support lamps such as fiber optic signs or front-illuminated reflective signs. This bit is not applicable to lamps or fluorescent lights illuminating the housing or cabinet. Bit 5- pixel error - this bit shall be set if any errors associated with any pixel occurs (see the objects pixelFailureTableNumRows for NTCIP 1203 v01 deployments, and pixelFailureTableNumRows, and/or dmsPixelFailureTestRows and dmsPixelFailureMessageRows for NTCIP 1203 v02 deployments.). This bit is only applicable to devices that support illumination of individual pixels, but not to drum signs. Note that certain sign technologies such as flip disk only sign may not be able to determine pixel errors. Bit 6- photocell error - this bit shall be set if any errors associated with the supported light sensors occurs (i.e., any bit set in fdSrsaTypeWarning.FAL). Bit 7- message error - this bit shall be set if any errors associated with activating and/or displaying a message occurs (see the object dmsActivateMsgError). Bit 8- controller error - this bit shall be set if any errors associated with the controller occurs (i.e., any bit set in fdControllerStatus). Bit 9- temperature warning - this bit shall be set if any of the temperature values detected by the device exceed non-standardized temperature values (i.e., any bit set in fdSrsaTypeWarning.FAT FET, or FPT). This bit is included to allow vendors or agencies to define vendor- or agency-specific threshold objects that indicate temperature changes that are of interest but not dangerous to the life-expectancy of the device (see also the 'critical temperature' bit) Bit 10- climate-control system error - this bit shall be set if any errors associated with the climate control systems such as fans and/or heaters occurs (i.e., any bit set in fdSrsaTypeWarning.FAC, FDC, FFO, FHO, or FTT). Bit 11- critical temperature error - this bit shall be set if the critical temperature as defined by the value of the critical temperature objects have been exceeded (i.e., any bit set in fdSrsaTypeStatus.FAT, FET, or FPT). Bit 12- Drum-sign Rotor error - This bit shall be set if any errors associated with the rotor of a drum sign occurs (i.e., any bit set in fdSrsaTypeWarning.MDS). Bit 13- This bit shall be set if any door to any DMS field component (cabinet or housing) is open (i.e., any bit set in fdSrsaTypeWarning.FDO). Bit 14- Humidity warning - This bit shall be set if any humidity sensor sensor is reporting a humidity warning (i.e., any bit set in fdSrsaTypeWarning.FAH or FEH). Bit 15- invisible default text - this bit shall be set if the value for defaultBackgroudRGB is equal to the value of defaultForegroundRGB, which would result in the message not being visible unless the MULTI string itself specifies alternate colors. <Informative> To track a history of transient error conditions utilize the event logging table located in the Global Objects Definitions (NTCIP 1201). <Parameter Type> Status <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1

Sources for this description

ITE public NTCIP working repository MIBs

See 1 matching source record

Description 5

<Definition> A bitmap of summary errors. When a bit is set, the error is presently active. When a bit is clear the error is not currently active. If no sensor is present or supported (for a corresponding bit), the bit shall not be set. The bits are defined as follows: <Format> Bit 0 - reserved -- The definition contained in Version 1 stated 'other'. However, -- 'other' is no longer allowed as a value. Bit 1- communications error - this bit shall be set if any error associated with the communications between the central computer and the device occurs. Bit 2- power error - this bit shall be set if any error associated with the power supply to any component occurs (see the objects dmsPowerFailureStatusMap and lowFuelThreshold). Bit 3- attached device error - this bit shall be set if any error associated with attached (supported, and enabled) external devices occurs. Bit 4- lamp error - this bit shall be set if any errors associated with any lamp occurs (see the objects lampFailureStuckOn and lampFailureStuckOff). This bit is only applicable to devices that support lamps such as fiber optic signs or front-illuminated reflective signs. This bit is not applicable to lamps or fluorescent lights illuminating the housing or cabinet. Bit 5- pixel error - this bit shall be set if any errors associated with any pixel occurs (see the objects pixelFailureTableNumRows for NTCIP 1203v1 deployments, and pixelFailureTableNumRows, and/or dmsPixelFailureTestRows and dmsPixelFailureMessageRows for NTCIP 1203v2 deployments.). This bit is only applicable to devices that support illumination of individual pixels, but not to drum signs. Note that certain sign technologies such as flip disk only sign may not be able to determine pixel errors. Bit 6- photocell error - this bit shall be set if any errors associated with the supported light sensors occurs (see the object dmsLightSensorStatusMap). Bit 7- message error - this bit shall be set if any errors associated with activating and/or displaying a message occurs (see the object dmsActivateMsgError). Bit 8- controller error - this bit shall be set if any errors associated with the controller occurs (see the controllerErrorStatus object) Bit 9- temperature warning - this bit shall be set if any of the temperature values detected by the device exceed non-standardized temperature values (see the object tempSensorWarningMap). This bit is included to allow vendors or agencies to define vendor- or agency-specific threshold objects that indicate temperature changes that are of interest but not dangerous to the life-expectancy of the device (see also the 'critical temperature' bit) Bit 10- climate-control system error - this bit shall be set if any errors associated with the climate control systems such as fans and/or heaters occurs (see the object dmsClimateCtrlStatusMap). Bit 11- critical temperature error - this bit shall be set if the critical temperature as defined by the value of the critical temperature objects have been exceeded. (see the object dmsTempSensorHighCriticalTemperature and dmsTempSensorLowCriticalTemperature). Bit 12- Drum-sign Rotor error - This bit shall be set if any errors associated with the rotor of a drum sign occurs. Bit 13- This bit shall be set if any door to any DMS field component (cabinet or housing) is open(see the object dmsStatDoorOpen). Bit 14- Humidity warning - This bit shall be set if any humidity sensor sensor is reporting a humidity warning (see the object dmsHumiditySensorStatusMap). -- To track a history of transient error conditions utilize the event -- logging table located in the Global Objects Definitions (NTCIP 1201). <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1

Sources for this description

ITE public NTCIP working repository MIBsNTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

5 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 1

shortErrorStatus · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: shortErrorStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "shortErrorStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "65535",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> A bitmap of summary errors. When a bit is set, the error is presently active. When a bit is clear the error is not currently active. If no sensor is present or supported (for a corresponding bit), the bit shall not be set. The bits are defined as follows: <Format> Bit 0 - reserved -- The definition contained in Version 1 stated 'other'. However, -- 'other' is no longer allowed as a value. Bit 1- communications error - this bit shall be set if any error associated with the communications between the central computer and the device occurs. Bit 2- power error - this bit shall be set if any error associated with the power supply to any component occurs (see the objects dmsPowerFailureStatusMap and lowFuelThreshold). Bit 3- attached device error - this bit shall be set if any error associated with attached (supported, and enabled) external devices occurs. Bit 4- lamp error - this bit shall be set if any errors associated with any lamp occurs (see the objects lampFailureStuckOn and lampFailureStuckOff). This bit will only be applicable to devices that support lamps such as fiber optic signs or front-illuminated reflective signs. This bit is not applicable to lamps or fluorescent lights illuminating the housing or cabinet. Bit 5- pixel error - this bit shall be set if any errors associated with any Page 190 NTCIP 1203 v02.35 pixel occurs (see the objects pixelFailureTableNumRows for NTCIP 1203v1 deployments, and pixelFailureTableNumRows, and/or dmsPixelFailureTestRows and dmsPixelFailureMessageRows for NTCIP 1203v2 deployments.). This bit will only be applicable to devices that support illumination of individual pixels, but not to drum signs. Note that certain sign technologies such as flip disk only sign may not be able to determine pixel errors. Bit 6- photocell error - this bit shall be set if any errors associated with the supported light sensors occurs (see the object dmsLightSensorStatusMap). Bit 7- message error - this bit shall be set if any errors associated with activating and/or displaying a message occurs (see the object dmsActivateMsgError). Bit 8- controller error - this bit shall be set if any errors associated with the controller occurs (see the controllerErrorStatus object) Bit 9- temperature warning - this bit shall be set if any of the temperature values detected by the device exceed non-standardized temperature values (see the object tempSensorWarningMap). This bit is included to allow vendors or agencies to define vendor- or agency-specific threshold objects that indicate temperature changes that are of interest but not dangerous to the life-expectancy of the device (see also the 'critical temperature' bit) Bit 10- climate-control system error - this bit shall be set if any errors associated with the climate control systems such as fans and/or heaters occurs (see the object dmsClimateCtrlStatusMap). Bit 11- critical temperature error - this bit shall be set if the critical temperature as defined by the value of the critical temperature objects have been exceeded. (see the object dmsTempSensorHighCriticalTemperature and dmsTempSensorLowCriticalTemperature). Bit 12- Drum-sign Rotor error - This bit shall be set if any errors associated with the rotor of a drum sign occurs. Bit 13- This bit shall be set if any door to any DMS field component (cabinet or housing) is open(see the object dmsStatDoorOpen). Bit 14- Humidity warning - This bit shall be set if any humidity sensor sensor is reporting a humidity warning (see the object dmsHumiditySensorStatusMap). -- To track a history of transient error conditions utilize the event -- logging table located in the Global Objects Definitions (NTCIP 1201). <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1\"",
    "::=",
    "{",
    "statError",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            65535
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> A bitmap of summary errors. When a bit is set, the error is presently active. When a bit is clear the error is not currently active. If no sensor is present or supported (for a corresponding bit), the bit shall not be set. The bits are defined as follows: <Format> Bit 0 - reserved -- The definition contained in Version 1 stated 'other'. However, -- 'other' is no longer allowed as a value. Bit 1- communications error - this bit shall be set if any error associated with the communications between the central computer and the device occurs. Bit 2- power error - this bit shall be set if any error associated with the power supply to any component occurs (see the objects dmsPowerFailureStatusMap and lowFuelThreshold). Bit 3- attached device error - this bit shall be set if any error associated with attached (supported, and enabled) external devices occurs. Bit 4- lamp error - this bit shall be set if any errors associated with any lamp occurs (see the objects lampFailureStuckOn and lampFailureStuckOff). This bit will only be applicable to devices that support lamps such as fiber optic signs or front-illuminated reflective signs. This bit is not applicable to lamps or fluorescent lights illuminating the housing or cabinet. Bit 5- pixel error - this bit shall be set if any errors associated with any Page 190 NTCIP 1203 v02.35 pixel occurs (see the objects pixelFailureTableNumRows for NTCIP 1203v1 deployments, and pixelFailureTableNumRows, and/or dmsPixelFailureTestRows and dmsPixelFailureMessageRows for NTCIP 1203v2 deployments.). This bit will only be applicable to devices that support illumination of individual pixels, but not to drum signs. Note that certain sign technologies such as flip disk only sign may not be able to determine pixel errors. Bit 6- photocell error - this bit shall be set if any errors associated with the supported light sensors occurs (see the object dmsLightSensorStatusMap). Bit 7- message error - this bit shall be set if any errors associated with activating and/or displaying a message occurs (see the object dmsActivateMsgError). Bit 8- controller error - this bit shall be set if any errors associated with the controller occurs (see the controllerErrorStatus object) Bit 9- temperature warning - this bit shall be set if any of the temperature values detected by the device exceed non-standardized temperature values (see the object tempSensorWarningMap). This bit is included to allow vendors or agencies to define vendor- or agency-specific threshold objects that indicate temperature changes that are of interest but not dangerous to the life-expectancy of the device (see also the 'critical temperature' bit) Bit 10- climate-control system error - this bit shall be set if any errors associated with the climate control systems such as fans and/or heaters occurs (see the object dmsClimateCtrlStatusMap). Bit 11- critical temperature error - this bit shall be set if the critical temperature as defined by the value of the critical temperature objects have been exceeded. (see the object dmsTempSensorHighCriticalTemperature and dmsTempSensorLowCriticalTemperature). Bit 12- Drum-sign Rotor error - This bit shall be set if any errors associated with the rotor of a drum sign occurs. Bit 13- This bit shall be set if any door to any DMS field component (cabinet or housing) is open(see the object dmsStatDoorOpen). Bit 14- Humidity warning - This bit shall be set if any humidity sensor sensor is reporting a humidity warning (see the object dmsHumiditySensorStatusMap). -- To track a history of transient error conditions utilize the event -- logging table located in the Global Objects Definitions (NTCIP 1201). <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 2

shortErrorStatus · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: shortErrorStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "shortErrorStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "65535",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "“",
    "A",
    "bitmap",
    "of",
    "summary",
    "errors",
    "where",
    "the",
    "bits",
    "are",
    "defined",
    "as",
    "follows",
    ":",
    "Bit",
    "0",
    "-",
    "other",
    "error",
    "Bit",
    "1",
    "-",
    "communications",
    "error",
    "Bit",
    "2",
    "-",
    "power",
    "error",
    "Bit",
    "3",
    "-",
    "attached",
    "device",
    "error",
    "Bit",
    "4",
    "-",
    "lamp",
    "error",
    "Bit",
    "5",
    "-",
    "pixel",
    "error",
    "Bit",
    "6",
    "-",
    "photocell",
    "error",
    "Bit",
    "7",
    "-",
    "message",
    "error",
    "Bit",
    "8",
    "-",
    "controller",
    "error",
    "Bit",
    "9",
    "-",
    "temperature",
    "warning",
    "Bit",
    "10",
    "-",
    "fan",
    "error",
    "If",
    "a",
    "bit",
    "is",
    "set",
    "to",
    "one",
    "(",
    "1",
    ")",
    ",",
    "then",
    "the",
    "associated",
    "error",
    "is",
    "existing",
    ";",
    "if",
    "the",
    "bit",
    "is",
    "set",
    "to",
    "zero",
    "(",
    "0",
    ")",
    ",",
    "then",
    "the",
    "associated",
    "error",
    "is",
    "not",
    "existing",
    ".",
    "”",
    "::=",
    "{",
    "statError",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            65535
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "A bitmap of summary errors where the bits are defined as follows: Bit 0- other error Bit 1- communications error Bit 2- power error Bit 3- attached device error Bit 4- lamp error Bit 5- pixel error Bit 6- photocell error Bit 7- message error Bit 8- controller error Bit 9- temperature warning Bit 10- fan error If a bit is set to one (1), then the associated error is existing; if the bit is set to zero (0), then the associated error is not existing."
    ],
    null,
    null,
    null,
    null
  ]
}
  • NTCIP published standard MIB annexes (reviewed modules) · Publisher's source file: NTCIP 1203:1997, Object Definitions for Dynamic Message Signs (DMS) Published December 1999 (superceded by NTCIP 1203 v02) — original PDF · Official record

    Module: DMS-MIB

    See published definition above

    Module imports
    {'TMIB': ['OwnerString', 'devices'], 'NEMA_SMI': ['experimental'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['IpAddress', 'Counter'], 'RFC1213-MIB': ['DisplayString']}

    Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.

    Source data warning: A typographic closing DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.

    Source data warning: A typographic opening DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: TMIB. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    Source data warning: Unconfirmed interpretation of a historical NTCIP import: NTCIP 1203:1997 imports experimental from NEMA_SMI, but the retained original NEMA_SMI defines nemaExperimental instead. Section 2.10 explicitly locates these auxiliary I/O objects under the nema-experimental node. Here only that imported spelling is interpreted as the explicitly assigned nemaExperimental value. The original exp-global suffix 1 and all child numbers are retained. The later NTCIP 1201 v03 compatibility discussion also compares the old experimental spelling with nemaExperimental, but prints expGlobal suffix 2; that disagreement is not silently corrected or treated as proof that both historical branches are registered. These entries may be inaccurate; verify the linked original editions and your device. Native SMI STATUS is preserved separately.

    Related ASN.1 definitions
    nema                     OBJECT IDENTIFIER ::= { enterprises 1206 }
    nemaExperimental         OBJECT IDENTIFIER ::= { nema 2 }
    · Download NTCIP1203v0115a.pdf — DMS-MIB (MIB transcription)
Records for description 3ITE public NTCIP working repository MIBs1 record · 1 source

Description 3

dmsOtherShortErrorDescr · unconfirmedITE public NTCIP working repository MIBs1 source

Status in source: unconfirmed.

Names: dmsOtherShortErrorDescr

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "dmsOtherShortErrorDescr",
    "OBJECT-TYPE",
    "SYNTAX",
    "SnmpAdminString",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"<Definition> A textual description of the 'other' error causing Bit 0 of shortErrorStatus to be set. This shall be a zero-length string when Bit 0 of shortErrorStatus is not set. The language used for this text-based message shall be as defined by ISO26048-1-Controller:fdDefaultLanguage. <Parameter Type> Status <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1\"",
    "::=",
    "{",
    "statError",
    "39",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "SnmpAdminString"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "<Definition> A textual description of the 'other' error causing Bit 0 of shortErrorStatus to be set. This shall be a zero-length string when Bit 0 of shortErrorStatus is not set. The language used for this text-based message shall be as defined by ISO26048-1-Controller:fdDefaultLanguage. <Parameter Type> Status <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1"
    ],
    null,
    null,
    null,
    null
  ]
}
  • ITE public NTCIP working repository MIBs · Publisher's source file: NTCIP-1203 — NTCIP1203-Dms.mib

    Module: NTCIP1203-Dms

    See published definition above

    Module imports
    {'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'StorageType', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'Counter32', 'IpAddress'], 'SNMPv2-CONF': ['OBJECT-GROUP'], 'ISO26048-1-Srsa': ['fdSrsaTypeCode', 'fdSrsaPortIndex'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'ISO26048-1-Global-TC': ['ITSDirection', 'ITSInteger8', 'ITSLatitude84', 'ITSLongitude84', 'ITSBitmap'], 'TRANSPORT-ADDRESS-MIB': ['TransportAddressType', 'TransportAddress'], 'NTCIP8004-Transportation': ['NtcipOwnerString', 'NtcipIntegerBitmap8', 'NtcipIntegerBitmap16', 'NtcipTwoColors', 'devices']}

    Source data warning: This original is published in an ITE NTCIP working repository. Repository publication does not establish that this particular revision is an adopted standard. Consult its native revision history and the NTCIP published standards catalog before implementation. Copyright and distribution notices are retained in the downloadable original.

    Source data warning: Published module-root disagreement: dms has an SMI assignment resolving to 1.3.6.1.4.1.1206.4.2.6, while its DESCRIPTION explicitly prints 1.3.6.1.4.1.1206.4.2.3. All dependent assignments from this module require verification. No root number has been silently corrected.

    Source data warning: Published source disagreement: this literal SMI assignment resolves to 1.3.6.1.4.1.1206.4.2.6.9.7.39, but its DESCRIPTION explicitly lists 1.3.6.1.4.1.1206.4.2.3.9.7.1. Both published numeric claims are retained as unconfirmed evidence. Neither value is presented as a verified correction or an independently confirmed registration; consult the original file and the applicable standard edition.

    · Download NTCIP-1203 — NTCIP1203-Dms.mib
Records for description 4ITE public NTCIP working repository MIBs1 record · 1 source

Description 4

shortErrorStatus · unconfirmedITE public NTCIP working repository MIBs1 source

Status in source: unconfirmed.

Names: shortErrorStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "shortErrorStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "NtcipIntegerBitmap16",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"<Definition> A bitmap of summary errors. When a bit is set, the error is presently active. When a bit is clear the error is not currently active. If no sensor is present or supported (for a corresponding bit), the bit shall not be set. <Format> The bits are defined as follows: Bit 0- other - not defined by this standard, see the value of dmsOtherShortErrorDescr. The value of other was deprecated in v02 and reinstated in v04. Bit 1- communications error - this bit shall be set if any error associated with the communications between the central computer and the device occurs. Bit 2- power error - this bit shall be set if any error is detected for any power supply associated with any component (i.e., any bit set in fdSrsaTypeWarning.FPA, FPS, or FPV) or if the generator fuel level is below its minimum threshold or has an error (i.e., any bit set in fdSrsaTypeWarning.FGF). Bit 3- attached device error - this bit shall be set if any error associated with attached (supported, and enabled) external devices occurs (i.e., any bit set in any fdSrsaTypeWarning object that is not otherwise specified by other bots of this object). Bit 4- lamp error - this bit shall be set if any errors associated with any lamp occurs (i.e., any bit set in fdSrsaTypeWarning.MLS) This bit is only applicable to devices that support lamps such as fiber optic signs or front-illuminated reflective signs. This bit is not applicable to lamps or fluorescent lights illuminating the housing or cabinet. Bit 5- pixel error - this bit shall be set if any errors associated with any pixel occurs (see the objects pixelFailureTableNumRows for NTCIP 1203 v01 deployments, and pixelFailureTableNumRows, and/or dmsPixelFailureTestRows and dmsPixelFailureMessageRows for NTCIP 1203 v02 deployments.). This bit is only applicable to devices that support illumination of individual pixels, but not to drum signs. Note that certain sign technologies such as flip disk only sign may not be able to determine pixel errors. Bit 6- photocell error - this bit shall be set if any errors associated with the supported light sensors occurs (i.e., any bit set in fdSrsaTypeWarning.FAL). Bit 7- message error - this bit shall be set if any errors associated with activating and/or displaying a message occurs (see the object dmsActivateMsgError). Bit 8- controller error - this bit shall be set if any errors associated with the controller occurs (i.e., any bit set in fdControllerStatus). Bit 9- temperature warning - this bit shall be set if any of the temperature values detected by the device exceed non-standardized temperature values (i.e., any bit set in fdSrsaTypeWarning.FAT FET, or FPT). This bit is included to allow vendors or agencies to define vendor- or agency-specific threshold objects that indicate temperature changes that are of interest but not dangerous to the life-expectancy of the device (see also the 'critical temperature' bit) Bit 10- climate-control system error - this bit shall be set if any errors associated with the climate control systems such as fans and/or heaters occurs (i.e., any bit set in fdSrsaTypeWarning.FAC, FDC, FFO, FHO, or FTT). Bit 11- critical temperature error - this bit shall be set if the critical temperature as defined by the value of the critical temperature objects have been exceeded (i.e., any bit set in fdSrsaTypeStatus.FAT, FET, or FPT). Bit 12- Drum-sign Rotor error - This bit shall be set if any errors associated with the rotor of a drum sign occurs (i.e., any bit set in fdSrsaTypeWarning.MDS). Bit 13- This bit shall be set if any door to any DMS field component (cabinet or housing) is open (i.e., any bit set in fdSrsaTypeWarning.FDO). Bit 14- Humidity warning - This bit shall be set if any humidity sensor sensor is reporting a humidity warning (i.e., any bit set in fdSrsaTypeWarning.FAH or FEH). Bit 15- invisible default text - this bit shall be set if the value for defaultBackgroudRGB is equal to the value of defaultForegroundRGB, which would result in the message not being visible unless the MULTI string itself specifies alternate colors. <Informative> To track a history of transient error conditions utilize the event logging table located in the Global Objects Definitions (NTCIP 1201). <Parameter Type> Status <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1\"",
    "::=",
    "{",
    "statError",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "NtcipIntegerBitmap16"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "<Definition> A bitmap of summary errors. When a bit is set, the error is presently active. When a bit is clear the error is not currently active. If no sensor is present or supported (for a corresponding bit), the bit shall not be set. <Format> The bits are defined as follows: Bit 0- other - not defined by this standard, see the value of dmsOtherShortErrorDescr. The value of other was deprecated in v02 and reinstated in v04. Bit 1- communications error - this bit shall be set if any error associated with the communications between the central computer and the device occurs. Bit 2- power error - this bit shall be set if any error is detected for any power supply associated with any component (i.e., any bit set in fdSrsaTypeWarning.FPA, FPS, or FPV) or if the generator fuel level is below its minimum threshold or has an error (i.e., any bit set in fdSrsaTypeWarning.FGF). Bit 3- attached device error - this bit shall be set if any error associated with attached (supported, and enabled) external devices occurs (i.e., any bit set in any fdSrsaTypeWarning object that is not otherwise specified by other bots of this object). Bit 4- lamp error - this bit shall be set if any errors associated with any lamp occurs (i.e., any bit set in fdSrsaTypeWarning.MLS) This bit is only applicable to devices that support lamps such as fiber optic signs or front-illuminated reflective signs. This bit is not applicable to lamps or fluorescent lights illuminating the housing or cabinet. Bit 5- pixel error - this bit shall be set if any errors associated with any pixel occurs (see the objects pixelFailureTableNumRows for NTCIP 1203 v01 deployments, and pixelFailureTableNumRows, and/or dmsPixelFailureTestRows and dmsPixelFailureMessageRows for NTCIP 1203 v02 deployments.). This bit is only applicable to devices that support illumination of individual pixels, but not to drum signs. Note that certain sign technologies such as flip disk only sign may not be able to determine pixel errors. Bit 6- photocell error - this bit shall be set if any errors associated with the supported light sensors occurs (i.e., any bit set in fdSrsaTypeWarning.FAL). Bit 7- message error - this bit shall be set if any errors associated with activating and/or displaying a message occurs (see the object dmsActivateMsgError). Bit 8- controller error - this bit shall be set if any errors associated with the controller occurs (i.e., any bit set in fdControllerStatus). Bit 9- temperature warning - this bit shall be set if any of the temperature values detected by the device exceed non-standardized temperature values (i.e., any bit set in fdSrsaTypeWarning.FAT FET, or FPT). This bit is included to allow vendors or agencies to define vendor- or agency-specific threshold objects that indicate temperature changes that are of interest but not dangerous to the life-expectancy of the device (see also the 'critical temperature' bit) Bit 10- climate-control system error - this bit shall be set if any errors associated with the climate control systems such as fans and/or heaters occurs (i.e., any bit set in fdSrsaTypeWarning.FAC, FDC, FFO, FHO, or FTT). Bit 11- critical temperature error - this bit shall be set if the critical temperature as defined by the value of the critical temperature objects have been exceeded (i.e., any bit set in fdSrsaTypeStatus.FAT, FET, or FPT). Bit 12- Drum-sign Rotor error - This bit shall be set if any errors associated with the rotor of a drum sign occurs (i.e., any bit set in fdSrsaTypeWarning.MDS). Bit 13- This bit shall be set if any door to any DMS field component (cabinet or housing) is open (i.e., any bit set in fdSrsaTypeWarning.FDO). Bit 14- Humidity warning - This bit shall be set if any humidity sensor sensor is reporting a humidity warning (i.e., any bit set in fdSrsaTypeWarning.FAH or FEH). Bit 15- invisible default text - this bit shall be set if the value for defaultBackgroudRGB is equal to the value of defaultForegroundRGB, which would result in the message not being visible unless the MULTI string itself specifies alternate colors. <Informative> To track a history of transient error conditions utilize the event logging table located in the Global Objects Definitions (NTCIP 1201). <Parameter Type> Status <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1"
    ],
    null,
    null,
    null,
    null
  ]
}
  • ITE public NTCIP working repository MIBs

    Module: NTCIP1203-Dms

    See published definition above

    Module imports
    {'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'StorageType', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'Counter32', 'IpAddress'], 'SNMPv2-CONF': ['OBJECT-GROUP'], 'ISO26048-1-Srsa': ['fdSrsaTypeCode', 'fdSrsaPortIndex'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'ISO26048-1-Global-TC': ['ITSDirection', 'ITSInteger8', 'ITSLatitude84', 'ITSLongitude84', 'ITSBitmap'], 'TRANSPORT-ADDRESS-MIB': ['TransportAddressType', 'TransportAddress'], 'NTCIP8004-Transportation': ['NtcipOwnerString', 'NtcipIntegerBitmap8', 'NtcipIntegerBitmap16', 'NtcipTwoColors', 'devices']}

    Source data warning: Published source disagreement: this literal SMI assignment resolves to 1.3.6.1.4.1.1206.4.2.6.9.7.1, but its DESCRIPTION explicitly lists 1.3.6.1.4.1.1206.4.2.3.9.7.1. Both published numeric claims are retained as unconfirmed evidence. Neither value is presented as a verified correction or an independently confirmed registration; consult the original file and the applicable standard edition.

Records for description 5ITE public NTCIP working repository MIBs, NTCIP published standard MIB annexes (reviewed modules)1 record · 2 sources

Description 5

shortErrorStatus · mandatoryITE public NTCIP working repository MIBs, NTCIP published standard MIB annexes (reviewed modules)2 sources

Status in source: mandatory.

Names: shortErrorStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "shortErrorStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "65535",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> A bitmap of summary errors. When a bit is set, the error is presently active. When a bit is clear the error is not currently active. If no sensor is present or supported (for a corresponding bit), the bit shall not be set. The bits are defined as follows: <Format> Bit 0 - reserved -- The definition contained in Version 1 stated 'other'. However, -- 'other' is no longer allowed as a value. Bit 1- communications error - this bit shall be set if any error associated with the communications between the central computer and the device occurs. Bit 2- power error - this bit shall be set if any error associated with the power supply to any component occurs (see the objects dmsPowerFailureStatusMap and lowFuelThreshold). Bit 3- attached device error - this bit shall be set if any error associated with attached (supported, and enabled) external devices occurs. Bit 4- lamp error - this bit shall be set if any errors associated with any lamp occurs (see the objects lampFailureStuckOn and lampFailureStuckOff). This bit is only applicable to devices that support lamps such as fiber optic signs or front-illuminated reflective signs. This bit is not applicable to lamps or fluorescent lights illuminating the housing or cabinet. Bit 5- pixel error - this bit shall be set if any errors associated with any pixel occurs (see the objects pixelFailureTableNumRows for NTCIP 1203v1 deployments, and pixelFailureTableNumRows, and/or dmsPixelFailureTestRows and dmsPixelFailureMessageRows for NTCIP 1203v2 deployments.). This bit is only applicable to devices that support illumination of individual pixels, but not to drum signs. Note that certain sign technologies such as flip disk only sign may not be able to determine pixel errors. Bit 6- photocell error - this bit shall be set if any errors associated with the supported light sensors occurs (see the object dmsLightSensorStatusMap). Bit 7- message error - this bit shall be set if any errors associated with activating and/or displaying a message occurs (see the object dmsActivateMsgError). Bit 8- controller error - this bit shall be set if any errors associated with the controller occurs (see the controllerErrorStatus object) Bit 9- temperature warning - this bit shall be set if any of the temperature values detected by the device exceed non-standardized temperature values (see the object tempSensorWarningMap). This bit is included to allow vendors or agencies to define vendor- or agency-specific threshold objects that indicate temperature changes that are of interest but not dangerous to the life-expectancy of the device (see also the 'critical temperature' bit) Bit 10- climate-control system error - this bit shall be set if any errors associated with the climate control systems such as fans and/or heaters occurs (see the object dmsClimateCtrlStatusMap). Bit 11- critical temperature error - this bit shall be set if the critical temperature as defined by the value of the critical temperature objects have been exceeded. (see the object dmsTempSensorHighCriticalTemperature and dmsTempSensorLowCriticalTemperature). Bit 12- Drum-sign Rotor error - This bit shall be set if any errors associated with the rotor of a drum sign occurs. Bit 13- This bit shall be set if any door to any DMS field component (cabinet or housing) is open(see the object dmsStatDoorOpen). Bit 14- Humidity warning - This bit shall be set if any humidity sensor sensor is reporting a humidity warning (see the object dmsHumiditySensorStatusMap). -- To track a history of transient error conditions utilize the event -- logging table located in the Global Objects Definitions (NTCIP 1201). <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1\"",
    "::=",
    "{",
    "statError",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            65535
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> A bitmap of summary errors. When a bit is set, the error is presently active. When a bit is clear the error is not currently active. If no sensor is present or supported (for a corresponding bit), the bit shall not be set. The bits are defined as follows: <Format> Bit 0 - reserved -- The definition contained in Version 1 stated 'other'. However, -- 'other' is no longer allowed as a value. Bit 1- communications error - this bit shall be set if any error associated with the communications between the central computer and the device occurs. Bit 2- power error - this bit shall be set if any error associated with the power supply to any component occurs (see the objects dmsPowerFailureStatusMap and lowFuelThreshold). Bit 3- attached device error - this bit shall be set if any error associated with attached (supported, and enabled) external devices occurs. Bit 4- lamp error - this bit shall be set if any errors associated with any lamp occurs (see the objects lampFailureStuckOn and lampFailureStuckOff). This bit is only applicable to devices that support lamps such as fiber optic signs or front-illuminated reflective signs. This bit is not applicable to lamps or fluorescent lights illuminating the housing or cabinet. Bit 5- pixel error - this bit shall be set if any errors associated with any pixel occurs (see the objects pixelFailureTableNumRows for NTCIP 1203v1 deployments, and pixelFailureTableNumRows, and/or dmsPixelFailureTestRows and dmsPixelFailureMessageRows for NTCIP 1203v2 deployments.). This bit is only applicable to devices that support illumination of individual pixels, but not to drum signs. Note that certain sign technologies such as flip disk only sign may not be able to determine pixel errors. Bit 6- photocell error - this bit shall be set if any errors associated with the supported light sensors occurs (see the object dmsLightSensorStatusMap). Bit 7- message error - this bit shall be set if any errors associated with activating and/or displaying a message occurs (see the object dmsActivateMsgError). Bit 8- controller error - this bit shall be set if any errors associated with the controller occurs (see the controllerErrorStatus object) Bit 9- temperature warning - this bit shall be set if any of the temperature values detected by the device exceed non-standardized temperature values (see the object tempSensorWarningMap). This bit is included to allow vendors or agencies to define vendor- or agency-specific threshold objects that indicate temperature changes that are of interest but not dangerous to the life-expectancy of the device (see also the 'critical temperature' bit) Bit 10- climate-control system error - this bit shall be set if any errors associated with the climate control systems such as fans and/or heaters occurs (see the object dmsClimateCtrlStatusMap). Bit 11- critical temperature error - this bit shall be set if the critical temperature as defined by the value of the critical temperature objects have been exceeded. (see the object dmsTempSensorHighCriticalTemperature and dmsTempSensorLowCriticalTemperature). Bit 12- Drum-sign Rotor error - This bit shall be set if any errors associated with the rotor of a drum sign occurs. Bit 13- This bit shall be set if any door to any DMS field component (cabinet or housing) is open(see the object dmsStatDoorOpen). Bit 14- Humidity warning - This bit shall be set if any humidity sensor sensor is reporting a humidity warning (see the object dmsHumiditySensorStatusMap). -- To track a history of transient error conditions utilize the event -- logging table located in the Global Objects Definitions (NTCIP 1201). <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.1"
    ],
    null,
    null,
    null,
    null
  ]
}
  • ITE public NTCIP working repository MIBs · Publisher's source file: NTCIP_1203 — v03/1203v03A-06g.mib

    Module: NTCIP1203-v0305

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['IpAddress', 'Counter'], 'RFC1213-MIB': ['DisplayString'], 'NTCIP8004v02': ['OwnerString', 'dms']}

    Source data warning: This original is published in an ITE NTCIP working repository. Repository publication does not establish that this particular revision is an adopted standard. Consult its native revision history and the NTCIP published standards catalog before implementation. Copyright and distribution notices are retained in the downloadable original.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP imports: the original references NTCIP8004v02, which is absent from the public repository snapshot. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP_1203 — v03/1203v03A-06g.mib
  • NTCIP published standard MIB annexes (reviewed modules) · Publisher's source file: NTCIP 1203 v03, Object Definitions for Dynamic Message Signs (DMS) Published September 2014 — original PDF · Official record

    Module: NTCIP1203-v03-05

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'NTCIP8004': ['OwnerString', 'dms'], 'RFC1155-SMI': ['IpAddress', 'Counter'], 'RFC1213-MIB': ['DisplayString']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.

    Source data warning: The PDF prints an invalid ASN.1 module label (NTCIP1203 v03.05). The derived transcription uses an equal-length internal parsing label; this is not an OID registration or an alteration of any numeric assignment. The original label and full PDF are retained.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: NTCIP8004. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP1203v03f.pdf — NTCIP1203-v03-05 (MIB transcription)

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (34)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.3.9.7.2 pixelFailureTableNumRows00
1.3.6.1.4.1.1206.4.2.3.9.7.3 pixelFailureTable16
1.3.6.1.4.1.1206.4.2.3.9.7.4 pixelTestActivation00
1.3.6.1.4.1.1206.4.2.3.9.7.5 lampFailureStuckOn00
1.3.6.1.4.1.1206.4.2.3.9.7.6 lampFailureStuckOff00
1.3.6.1.4.1.1206.4.2.3.9.7.7 lampTestActivation00
1.3.6.1.4.1.1206.4.2.3.9.7.8 fanFailures00
1.3.6.1.4.1.1206.4.2.3.9.7.9 fanTestActivation00
1.3.6.1.4.1.1206.4.2.3.9.7.10 controllerErrorStatus00
1.3.6.1.4.1.1206.4.2.3.9.7.11 dmsPowerFailureStatusMap00
1.3.6.1.4.1.1206.4.2.3.9.7.12 dmsPowerNumRows00
1.3.6.1.4.1.1206.4.2.3.9.7.13 dmsPowerStatusTable17
1.3.6.1.4.1.1206.4.2.3.9.7.14 dmsClimateCtrlStatusMap00
1.3.6.1.4.1.1206.4.2.3.9.7.16 dmsClimateCtrlNumRows00
1.3.6.1.4.1.1206.4.2.3.9.7.17 dmsClimateCtrlStatusTable19
1.3.6.1.4.1.1206.4.2.3.9.7.18 pixelStatusTable14
1.3.6.1.4.1.1206.4.2.3.9.7.19 dmsPixelFailureTestRows00
1.3.6.1.4.1.1206.4.2.3.9.7.20 dmsPixelFailureMessageRows00
1.3.6.1.4.1.1206.4.2.3.9.7.23 dmsLampNumRows00
1.3.6.1.4.1.1206.4.2.3.9.7.24 dmsLampStatusTable19
1.3.6.1.4.1.1206.4.2.3.9.7.25 dmsDrumStatusMap00
1.3.6.1.4.1.1206.4.2.3.9.7.26 dmsDrumNumRows00
1.3.6.1.4.1.1206.4.2.3.9.7.27 dmsDrumStatusTable15
1.3.6.1.4.1.1206.4.2.3.9.7.28 dmsLightSensorStatusMap00
1.3.6.1.4.1.1206.4.2.3.9.7.29 dmsLightSensorNumRows00
1.3.6.1.4.1.1206.4.2.3.9.7.30 dmsLightSensorStatusTable15
1.3.6.1.4.1.1206.4.2.3.9.7.31 dmsHumiditySensorStatusMap00
1.3.6.1.4.1.1206.4.2.3.9.7.32 dmsHumiditySensorNumRows00
1.3.6.1.4.1.1206.4.2.3.9.7.33 dmsHumiditySensorStatusTable15
1.3.6.1.4.1.1206.4.2.3.9.7.34 dmsTempSensorStatusMap00
1.3.6.1.4.1.1206.4.2.3.9.7.35 dmsTempSensorNumRows00
1.3.6.1.4.1.1206.4.2.3.9.7.36 dmsTempSensorStatusTable19
1.3.6.1.4.1.1206.4.2.3.9.7.37 dmsTempSensorHighestCriticalTempThreshold00
1.3.6.1.4.1.1206.4.2.3.9.7.38 dmsTempSensorLowestCriticalTempThreshold00