OID reference

lampTestActivation

1.3.6.1.4.1.1206.4.2.3.9.7.7

Description

<Definition> Indicates the state of the lamp testing. The actual test routine can vary among different manufacturers. The results of the lamp failure test shall be stored appropriately, in the lampFailureStuckOn- and/or in the lampFailureStuckOff-objects. In v02, the enumerated value of 'other' was deprecated to impro…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.3.9.7 (statError)
Node code
7
Node name
lampTestActivation
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.3.9.7.7
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.3.9.7.7
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 3 9 7 7}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(3) dmsStatus(9) statError(7) lampTestActivation(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) fontDefinition(3) dmsStatus(9) statError(7) lampTestActivation(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(3) dmsStatus(9) statError(7) lampTestActivation(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) fontDefinition(3) dmsStatus(9) statError(7) lampTestActivation(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) dms(3) dmsStatus(9) statError(7) lampTestActivation(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) fontDefinition(3) dmsStatus(9) statError(7) lampTestActivation(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) dms(3) dmsStatus(9) statError(7) lampTestActivation(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) fontDefinition(3) dmsStatus(9) statError(7) lampTestActivation(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(3) dmsStatus(9) statError(7) lampTestActivation(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) fontDefinition(3) dmsStatus(9) statError(7) lampTestActivation(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(3) dmsStatus(9) statError(7) lampTestActivation(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) fontDefinition(3) dmsStatus(9) statError(7) lampTestActivation(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) dms(3) dmsStatus(9) statError(7) lampTestActivation(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) fontDefinition(3) dmsStatus(9) statError(7) lampTestActivation(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) dms(3) dmsStatus(9) statError(7) lampTestActivation(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) fontDefinition(3) dmsStatus(9) statError(7) lampTestActivation(7)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/3/9/7/7
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/3/9/7/7
  • /ISO/3/6/1/4/1/1206/4/2/3/9/7/7
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/dmsStatus/statError/lampTestActivation
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/fontDefinition/dmsStatus/statError/lampTestActivation
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/dmsStatus/statError/lampTestActivation
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/fontDefinition/dmsStatus/statError/lampTestActivation
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/dms/dmsStatus/statError/lampTestActivation
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/fontDefinition/dmsStatus/statError/lampTestActivation
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/dms/dmsStatus/statError/lampTestActivation
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/fontDefinition/dmsStatus/statError/lampTestActivation
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/dms/dmsStatus/statError/lampTestActivation
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/fontDefinition/dmsStatus/statError/lampTestActivation
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/dms/dmsStatus/statError/lampTestActivation
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/fontDefinition/dmsStatus/statError/lampTestActivation
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/dms/dmsStatus/statError/lampTestActivation
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/fontDefinition/dmsStatus/statError/lampTestActivation
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/dms/dmsStatus/statError/lampTestActivation
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/fontDefinition/dmsStatus/statError/lampTestActivation
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
deprecated, mandatory
Default value
noTest

Definitions may combine these properties differently.

Compare 3 source variants

Variant 1 — ITE public NTCIP working repository MIBs

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
deprecated
Default value
noTest

Variant 2 — NTCIP published standard MIB annexes (reviewed modules)

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Variant 3 — NTCIP published standard MIB annexes (reviewed modules), ITE public NTCIP working repository MIBs

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory
Default value
noTest

Enumerated values

Numbers refer to source variants above. Each value is shown only for variants that define it. Notes below names come from selected MIB definitions.

ValueName and source notesSource variants
1other
deprecated
1, 2
2noTest1, 2, 3
3test1, 2, 3

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.3.9.7.7.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 5 distinct definitions; some records may not include a definition.

Show 5 published definitions

lampTestActivation · unconfirmed

lampTestActivation  OBJECT-TYPE 
SYNTAX      INTEGER {
                 other (1), -- deprecated 
                 noTest (2),
                 test (3) } 
MAX-ACCESS  read-write 
STATUS      deprecated  
DESCRIPTION  
"<Definition> Indicates the state of the lamp testing. The actual test 
routine can vary among different manufacturers. The results of the lamp 
failure test shall be stored appropriately, in the lampFailureStuckOn- and/or 
in the lampFailureStuckOff-objects. In v02, the enumerated value of 'other' 
was deprecated to improve interoperability.
Setting the value to test starts the test, meaning this test is executed 
once. The sign controller shall automatically set the value of this object 
back to noTest after completion. Activation of lamp test shall clear the 
object lampFailureStuckOn and lampFailureStuckOff, the lamp status table, and 
the 'lamp fail' error bit in shortErrorStatus. Results of the lamp test shall 
update these two objects, the table and the error bit.
<Superseded by> ISO26048-1-Srsa:fdSrsaTypeTestActivation.MLS
<Informative> This object was deprecated in NTCIP 1203 v04 and replaced with 
the more universal SRSA object.
<Parameter Type> Control
<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.7"
DEFVAL  {noTest} 
::= { statError 7 }

lampTestActivation · mandatory

lampTestActivation OBJECT-TYPE
SYNTAX            INTEGER {
                             other (1),
                             noTest (2),
                             test (3)
                             }
ACCESS            read-write
STATUS            mandatory
DESCRIPTION “Indicates the state of the lamp testing. The actual test routine can vary among different
manufacturers. The results of the lamp failure test shall be stored appropriately, either in the
lampFailureStuckOn- or in the lampFailureStuckOff-objects. Setting the value to test will start the test,
meaning this test will be executed once. The sign controller shall automatically set the value of this
object back to noTest after completion.”
::= {statError 7}

lampTestActivation · mandatory

lampTestActivation OBJECT-TYPE
SYNTAX INTEGER {
                  --other (1), -retired
                  noTest (2),
                  test (3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"<Definition> Indicates the state of the lamp testing. The actual test
routine can vary among different manufacturers. The results of the lamp
failure test shall be stored appropriately, in the lampFailureStuckOn- and/or
in the lampFailureStuckOff-objects. Setting the value to test will start the
test, meaning this test will be executed once. The sign controller shall
automatically set the value of this object back to noTest after completion.
Activation of lamp test shall clear the object lampFailureStuckOn and
lampFailureStuckOff, the lamp status table, and the 'lamp fail' error bit in
shortErrorStatus. Results of the lamp test should update these two objects,
the table and the error bit.
<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.7"
DEFVAL {noTest}
::= { statError 7 }

lampTestActivation · mandatory

lampTestActivation  OBJECT-TYPE
SYNTAX  INTEGER {
                 --other (1), -retired
                 noTest (2),
                 test (3) }
ACCESS  read-write
STATUS  mandatory
DESCRIPTION 
"<Definition> Indicates the state of the lamp testing. The actual test routine can vary among different manufacturers. The results of the lamp failure test shall be stored appropriately, in the lampFailureStuckOn- and/or in the lampFailureStuckOff-objects. Setting the value to test starts the test, meaning this test is executed once. The sign controller shall automatically set the value of this object back to noTest after completion. Activation of lamp test shall clear the object lampFailureStuckOn and lampFailureStuckOff, the lamp status table, and the 'lamp fail' error bit in shortErrorStatus. Results of the lamp test shall update these two objects, the table and the error bit.
<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.7"
DEFVAL  {noTest}
::= { statError 7 }

lampTestActivation · mandatory

lampTestActivation OBJECT-TYPE
SYNTAX INTEGER {
                     --other (1), -retired
                     noTest (2),
                     test (3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"<Definition> Indicates the state of the lamp testing. The actual test
routine can vary among different manufacturers. The results of the lamp
failure test shall be stored appropriately, in the lampFailureStuckOn- and/or
in the lampFailureStuckOff-objects. Setting the value to test starts the
test, meaning this test is executed once. The sign controller shall
automatically set the value of this object back to noTest after completion.
Activation of lamp test shall clear the object lampFailureStuckOn and
lampFailureStuckOff, the lamp status table, and the 'lamp fail' error bit in
shortErrorStatus. Results of the lamp test shall update these two objects,
the table and the error bit.
<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.7"
DEFVAL {noTest}
::= { statError 7 }

Meaning

Descriptions

4 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

<Definition> Indicates the state of the lamp testing. The actual test routine can vary among different manufacturers. The results of the lamp failure test shall be stored appropriately, in the lampFailureStuckOn- and/or in the lampFailureStuckOff-objects. In v02, the enumerated value of 'other' was deprecated to improve interoperability. Setting the value to test starts the test, meaning this test is executed once. The sign controller shall automatically set the value of this object back to noTest after completion. Activation of lamp test shall clear the object lampFailureStuckOn and lampFailureStuckOff, the lamp status table, and the 'lamp fail' error bit in shortErrorStatus. Results of the lamp test shall update these two objects, the table and the error bit. <Superseded by> ISO26048-1-Srsa:fdSrsaTypeTestActivation.MLS <Informative> This object was deprecated in NTCIP 1203 v04 and replaced with the more universal SRSA object. <Parameter Type> Control <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.7

Sources for this description

ITE public NTCIP working repository MIBs

See 1 matching source record

Description 2

Indicates the state of the lamp testing. The actual test routine can vary among different manufacturers. The results of the lamp failure test shall be stored appropriately, either in the lampFailureStuckOn- or in the lampFailureStuckOff-objects. Setting the value to test will start the test, meaning this test will be executed once. The sign controller shall automatically set the value of this object back to noTest after completion.

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 3

<Definition> Indicates the state of the lamp testing. The actual test routine can vary among different manufacturers. The results of the lamp failure test shall be stored appropriately, in the lampFailureStuckOn- and/or in the lampFailureStuckOff-objects. Setting the value to test will start the test, meaning this test will be executed once. The sign controller shall automatically set the value of this object back to noTest after completion. Activation of lamp test shall clear the object lampFailureStuckOn and lampFailureStuckOff, the lamp status table, and the 'lamp fail' error bit in shortErrorStatus. Results of the lamp test should update these two objects, the table and the error bit. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.7

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 4

<Definition> Indicates the state of the lamp testing. The actual test routine can vary among different manufacturers. The results of the lamp failure test shall be stored appropriately, in the lampFailureStuckOn- and/or in the lampFailureStuckOff-objects. Setting the value to test starts the test, meaning this test is executed once. The sign controller shall automatically set the value of this object back to noTest after completion. Activation of lamp test shall clear the object lampFailureStuckOn and lampFailureStuckOff, the lamp status table, and the 'lamp fail' error bit in shortErrorStatus. Results of the lamp test shall update these two objects, the table and the error bit. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.7

Sources for this description

ITE public NTCIP working repository MIBsNTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

4 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1ITE public NTCIP working repository MIBs1 record · 1 source

Description 1

lampTestActivation · unconfirmedITE public NTCIP working repository MIBs1 source

Status in source: unconfirmed.

Names: lampTestActivation

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "lampTestActivation",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "noTest",
    "(",
    "2",
    ")",
    ",",
    "test",
    "(",
    "3",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "deprecated",
    "DESCRIPTION",
    "\"<Definition> Indicates the state of the lamp testing. The actual test routine can vary among different manufacturers. The results of the lamp failure test shall be stored appropriately, in the lampFailureStuckOn- and/or in the lampFailureStuckOff-objects. In v02, the enumerated value of 'other' was deprecated to improve interoperability. Setting the value to test starts the test, meaning this test is executed once. The sign controller shall automatically set the value of this object back to noTest after completion. Activation of lamp test shall clear the object lampFailureStuckOn and lampFailureStuckOff, the lamp status table, and the 'lamp fail' error bit in shortErrorStatus. Results of the lamp test shall update these two objects, the table and the error bit. <Superseded by> ISO26048-1-Srsa:fdSrsaTypeTestActivation.MLS <Informative> This object was deprecated in NTCIP 1203 v04 and replaced with the more universal SRSA object. <Parameter Type> Control <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.7\"",
    "DEFVAL",
    "{",
    "noTest",
    "}",
    "::=",
    "{",
    "statError",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "noTest",
            2
          ],
          [
            "test",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "deprecated"
    ],
    [
      "DESCRIPTION",
      "<Definition> Indicates the state of the lamp testing. The actual test routine can vary among different manufacturers. The results of the lamp failure test shall be stored appropriately, in the lampFailureStuckOn- and/or in the lampFailureStuckOff-objects. In v02, the enumerated value of 'other' was deprecated to improve interoperability. Setting the value to test starts the test, meaning this test is executed once. The sign controller shall automatically set the value of this object back to noTest after completion. Activation of lamp test shall clear the object lampFailureStuckOn and lampFailureStuckOff, the lamp status table, and the 'lamp fail' error bit in shortErrorStatus. Results of the lamp test shall update these two objects, the table and the error bit. <Superseded by> ISO26048-1-Srsa:fdSrsaTypeTestActivation.MLS <Informative> This object was deprecated in NTCIP 1203 v04 and replaced with the more universal SRSA object. <Parameter Type> Control <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.7"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "noTest"
    ]
  ]
}
  • ITE public NTCIP working repository MIBs · Publisher's source file: NTCIP-1203 — NTCIP1203-Dms.mib

    Module: NTCIP1203-Dms

    See published definition above

    Module imports
    {'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'StorageType', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'Counter32', 'IpAddress'], 'SNMPv2-CONF': ['OBJECT-GROUP'], 'ISO26048-1-Srsa': ['fdSrsaTypeCode', 'fdSrsaPortIndex'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'ISO26048-1-Global-TC': ['ITSDirection', 'ITSInteger8', 'ITSLatitude84', 'ITSLongitude84', 'ITSBitmap'], 'TRANSPORT-ADDRESS-MIB': ['TransportAddressType', 'TransportAddress'], 'NTCIP8004-Transportation': ['NtcipOwnerString', 'NtcipIntegerBitmap8', 'NtcipIntegerBitmap16', 'NtcipTwoColors', 'devices']}

    Source data warning: This original is published in an ITE NTCIP working repository. Repository publication does not establish that this particular revision is an adopted standard. Consult its native revision history and the NTCIP published standards catalog before implementation. Copyright and distribution notices are retained in the downloadable original.

    Source data warning: Published module-root disagreement: dms has an SMI assignment resolving to 1.3.6.1.4.1.1206.4.2.6, while its DESCRIPTION explicitly prints 1.3.6.1.4.1.1206.4.2.3. All dependent assignments from this module require verification. No root number has been silently corrected.

    Source data warning: Published source disagreement: this literal SMI assignment resolves to 1.3.6.1.4.1.1206.4.2.6.9.7.7, but its DESCRIPTION explicitly lists 1.3.6.1.4.1.1206.4.2.3.9.7.7. Both published numeric claims are retained as unconfirmed evidence. Neither value is presented as a verified correction or an independently confirmed registration; consult the original file and the applicable standard edition.

    · Download NTCIP-1203 — NTCIP1203-Dms.mib
Records for description 2NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 2

lampTestActivation · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: lampTestActivation

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "lampTestActivation",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "noTest",
    "(",
    "2",
    ")",
    ",",
    "test",
    "(",
    "3",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "“",
    "Indicates",
    "the",
    "state",
    "of",
    "the",
    "lamp",
    "testing",
    ".",
    "The",
    "actual",
    "test",
    "routine",
    "can",
    "vary",
    "among",
    "different",
    "manufacturers",
    ".",
    "The",
    "results",
    "of",
    "the",
    "lamp",
    "failure",
    "test",
    "shall",
    "be",
    "stored",
    "appropriately",
    ",",
    "either",
    "in",
    "the",
    "lampFailureStuckOn-",
    "or",
    "in",
    "the",
    "lampFailureStuckOff-objects",
    ".",
    "Setting",
    "the",
    "value",
    "to",
    "test",
    "will",
    "start",
    "the",
    "test",
    ",",
    "meaning",
    "this",
    "test",
    "will",
    "be",
    "executed",
    "once",
    ".",
    "The",
    "sign",
    "controller",
    "shall",
    "automatically",
    "set",
    "the",
    "value",
    "of",
    "this",
    "object",
    "back",
    "to",
    "noTest",
    "after",
    "completion",
    ".",
    "”",
    "::=",
    "{",
    "statError",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "noTest",
            2
          ],
          [
            "test",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Indicates the state of the lamp testing. The actual test routine can vary among different manufacturers. The results of the lamp failure test shall be stored appropriately, either in the lampFailureStuckOn- or in the lampFailureStuckOff-objects. Setting the value to test will start the test, meaning this test will be executed once. The sign controller shall automatically set the value of this object back to noTest after completion."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 3NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 3

lampTestActivation · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: lampTestActivation

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "lampTestActivation",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "noTest",
    "(",
    "2",
    ")",
    ",",
    "test",
    "(",
    "3",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> Indicates the state of the lamp testing. The actual test routine can vary among different manufacturers. The results of the lamp failure test shall be stored appropriately, in the lampFailureStuckOn- and/or in the lampFailureStuckOff-objects. Setting the value to test will start the test, meaning this test will be executed once. The sign controller shall automatically set the value of this object back to noTest after completion. Activation of lamp test shall clear the object lampFailureStuckOn and lampFailureStuckOff, the lamp status table, and the 'lamp fail' error bit in shortErrorStatus. Results of the lamp test should update these two objects, the table and the error bit. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.7\"",
    "DEFVAL",
    "{",
    "noTest",
    "}",
    "::=",
    "{",
    "statError",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "noTest",
            2
          ],
          [
            "test",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> Indicates the state of the lamp testing. The actual test routine can vary among different manufacturers. The results of the lamp failure test shall be stored appropriately, in the lampFailureStuckOn- and/or in the lampFailureStuckOff-objects. Setting the value to test will start the test, meaning this test will be executed once. The sign controller shall automatically set the value of this object back to noTest after completion. Activation of lamp test shall clear the object lampFailureStuckOn and lampFailureStuckOff, the lamp status table, and the 'lamp fail' error bit in shortErrorStatus. Results of the lamp test should update these two objects, the table and the error bit. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.7"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "noTest"
    ]
  ]
}
Records for description 4ITE public NTCIP working repository MIBs, NTCIP published standard MIB annexes (reviewed modules)1 record · 2 sources

Description 4

lampTestActivation · mandatoryITE public NTCIP working repository MIBs, NTCIP published standard MIB annexes (reviewed modules)2 sources

Status in source: mandatory.

Names: lampTestActivation

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "lampTestActivation",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "noTest",
    "(",
    "2",
    ")",
    ",",
    "test",
    "(",
    "3",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> Indicates the state of the lamp testing. The actual test routine can vary among different manufacturers. The results of the lamp failure test shall be stored appropriately, in the lampFailureStuckOn- and/or in the lampFailureStuckOff-objects. Setting the value to test starts the test, meaning this test is executed once. The sign controller shall automatically set the value of this object back to noTest after completion. Activation of lamp test shall clear the object lampFailureStuckOn and lampFailureStuckOff, the lamp status table, and the 'lamp fail' error bit in shortErrorStatus. Results of the lamp test shall update these two objects, the table and the error bit. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.7\"",
    "DEFVAL",
    "{",
    "noTest",
    "}",
    "::=",
    "{",
    "statError",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "noTest",
            2
          ],
          [
            "test",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> Indicates the state of the lamp testing. The actual test routine can vary among different manufacturers. The results of the lamp failure test shall be stored appropriately, in the lampFailureStuckOn- and/or in the lampFailureStuckOff-objects. Setting the value to test starts the test, meaning this test is executed once. The sign controller shall automatically set the value of this object back to noTest after completion. Activation of lamp test shall clear the object lampFailureStuckOn and lampFailureStuckOff, the lamp status table, and the 'lamp fail' error bit in shortErrorStatus. Results of the lamp test shall update these two objects, the table and the error bit. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.9.7.7"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "noTest"
    ]
  ]
}
  • ITE public NTCIP working repository MIBs · Publisher's source file: NTCIP_1203 — v03/1203v03A-06g.mib

    Module: NTCIP1203-v0305

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['IpAddress', 'Counter'], 'RFC1213-MIB': ['DisplayString'], 'NTCIP8004v02': ['OwnerString', 'dms']}

    Source data warning: This original is published in an ITE NTCIP working repository. Repository publication does not establish that this particular revision is an adopted standard. Consult its native revision history and the NTCIP published standards catalog before implementation. Copyright and distribution notices are retained in the downloadable original.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP imports: the original references NTCIP8004v02, which is absent from the public repository snapshot. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP_1203 — v03/1203v03A-06g.mib
  • NTCIP published standard MIB annexes (reviewed modules) · Publisher's source file: NTCIP 1203 v03, Object Definitions for Dynamic Message Signs (DMS) Published September 2014 — original PDF · Official record

    Module: NTCIP1203-v03-05

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'NTCIP8004': ['OwnerString', 'dms'], 'RFC1155-SMI': ['IpAddress', 'Counter'], 'RFC1213-MIB': ['DisplayString']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.

    Source data warning: The PDF prints an invalid ASN.1 module label (NTCIP1203 v03.05). The derived transcription uses an equal-length internal parsing label; this is not an OID registration or an alteration of any numeric assignment. The original label and full PDF are retained.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: NTCIP8004. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP1203v03f.pdf — NTCIP1203-v03-05 (MIB transcription)

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (34)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.3.9.7.1 dmsOtherShortErrorDescr, shortErrorStatus00
1.3.6.1.4.1.1206.4.2.3.9.7.2 pixelFailureTableNumRows00
1.3.6.1.4.1.1206.4.2.3.9.7.3 pixelFailureTable16
1.3.6.1.4.1.1206.4.2.3.9.7.4 pixelTestActivation00
1.3.6.1.4.1.1206.4.2.3.9.7.5 lampFailureStuckOn00
1.3.6.1.4.1.1206.4.2.3.9.7.6 lampFailureStuckOff00
1.3.6.1.4.1.1206.4.2.3.9.7.8 fanFailures00
1.3.6.1.4.1.1206.4.2.3.9.7.9 fanTestActivation00
1.3.6.1.4.1.1206.4.2.3.9.7.10 controllerErrorStatus00
1.3.6.1.4.1.1206.4.2.3.9.7.11 dmsPowerFailureStatusMap00
1.3.6.1.4.1.1206.4.2.3.9.7.12 dmsPowerNumRows00
1.3.6.1.4.1.1206.4.2.3.9.7.13 dmsPowerStatusTable17
1.3.6.1.4.1.1206.4.2.3.9.7.14 dmsClimateCtrlStatusMap00
1.3.6.1.4.1.1206.4.2.3.9.7.16 dmsClimateCtrlNumRows00
1.3.6.1.4.1.1206.4.2.3.9.7.17 dmsClimateCtrlStatusTable19
1.3.6.1.4.1.1206.4.2.3.9.7.18 pixelStatusTable14
1.3.6.1.4.1.1206.4.2.3.9.7.19 dmsPixelFailureTestRows00
1.3.6.1.4.1.1206.4.2.3.9.7.20 dmsPixelFailureMessageRows00
1.3.6.1.4.1.1206.4.2.3.9.7.23 dmsLampNumRows00
1.3.6.1.4.1.1206.4.2.3.9.7.24 dmsLampStatusTable19
1.3.6.1.4.1.1206.4.2.3.9.7.25 dmsDrumStatusMap00
1.3.6.1.4.1.1206.4.2.3.9.7.26 dmsDrumNumRows00
1.3.6.1.4.1.1206.4.2.3.9.7.27 dmsDrumStatusTable15
1.3.6.1.4.1.1206.4.2.3.9.7.28 dmsLightSensorStatusMap00
1.3.6.1.4.1.1206.4.2.3.9.7.29 dmsLightSensorNumRows00
1.3.6.1.4.1.1206.4.2.3.9.7.30 dmsLightSensorStatusTable15
1.3.6.1.4.1.1206.4.2.3.9.7.31 dmsHumiditySensorStatusMap00
1.3.6.1.4.1.1206.4.2.3.9.7.32 dmsHumiditySensorNumRows00
1.3.6.1.4.1.1206.4.2.3.9.7.33 dmsHumiditySensorStatusTable15
1.3.6.1.4.1.1206.4.2.3.9.7.34 dmsTempSensorStatusMap00
1.3.6.1.4.1.1206.4.2.3.9.7.35 dmsTempSensorNumRows00
1.3.6.1.4.1.1206.4.2.3.9.7.36 dmsTempSensorStatusTable19
1.3.6.1.4.1.1206.4.2.3.9.7.37 dmsTempSensorHighestCriticalTempThreshold00
1.3.6.1.4.1.1206.4.2.3.9.7.38 dmsTempSensorLowestCriticalTempThreshold00