OID reference

zoneInductance

1.3.6.1.4.1.1206.4.2.4.4.3.1.1

Description

<Definition> The detector unit calculates the inductance of the loop attached to the zone. The resolution is in tenths of a microHenry. For example, 852.4 microHenries is represented as 8524. Resolution does not imply accuracy, refer to manufacturers' data sheet. A value of 65535 shall be returned to represent invalid…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.4.4.3.1 (loopSystemStatusEntry)
Node code
1
Node name
zoneInductance
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.4.4.3.1.1
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.4.4.3.1.1
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 4 4 3 1 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductance(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductance(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductance(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductance(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductance(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductance(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductance(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductance(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductance(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductance(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductance(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductance(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductance(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductance(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductance(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductance(1)}
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/4/4/3/1/1
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/4/4/3/1/1
  • /ISO/3/6/1/4/1/1206/4/2/4/4/3/1/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductance
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductance
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductance
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductance
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductance
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductance
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductance
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductance
  • /iso/org/dod/internet/private/enterprise/1206/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductance
  • /iso/org/dod/internet/private/enterprise/nema/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductance
  • /iso/org/dod/internet/private/enterprises/1206/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductance
  • /iso/org/dod/internet/private/enterprises/nema/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductance
  • /iso/org/dod/internet/private/ldap-enterprise/1206/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductance
  • /iso/org/dod/internet/private/ldap-enterprise/nema/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductance
  • /iso/org/dod/internet/private/vendor-objects/1206/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductance
  • /iso/org/dod/internet/private/vendor-objects/nema/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductance
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
optional
Allowed ranges
0–65535

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In NTCIP1209v02-MIB1, the row index sensorZoneNumber is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.1206.4.2.4.4.3.1.1.<sensorZoneNumber>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.4.4.3.1.1

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

zoneInductance · optional

zoneInductance  OBJECT-TYPE
SYNTAX  INTEGER (0..65535)
ACCESS  read-only
STATUS  optional
DESCRIPTION 
"<Definition> The detector unit calculates the inductance of the loop attached to the zone. The resolution is in tenths of a microHenry. For example, 852.4 microHenries is represented as 8524. Resolution does not imply accuracy, refer to manufacturers' data sheet. A value of 65535 shall be returned to represent invalid data or not a physical zone.
<Unit> tenths of a microHenry
<Object Identifier> 1.3.6.1.4.1.1206.4.2.4.4.3.1.1"
::= { loopSystemStatusEntry 1 }

zoneInductance · optional

zoneInductance OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"<Definition> The detector unit calculates the inductance of the loop
attached to the zone. The resolution is in tenths of a microHenry. For
example, 852.4 microHenries is represented as 8524. Resolution does not imply
accuracy, refer to manufacturers' data sheet. A value of 65535 shall be
returned to represent invalid data or not a physical zone.
<Unit> tenths of a microHenry
<Object Identifier> 1.3.6.1.4.1.1206.4.2.4.4.3.1.1"
::= { loopSystemStatusEntry 1 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

<Definition> The detector unit calculates the inductance of the loop attached to the zone. The resolution is in tenths of a microHenry. For example, 852.4 microHenries is represented as 8524. Resolution does not imply accuracy, refer to manufacturers' data sheet. A value of 65535 shall be returned to represent invalid data or not a physical zone. <Unit> tenths of a microHenry <Object Identifier> 1.3.6.1.4.1.1206.4.2.4.4.3.1.1

Sources for this description

ITE public NTCIP working repository MIBsNTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1ITE public NTCIP working repository MIBs, NTCIP published standard MIB annexes (reviewed modules)1 record · 2 sources

Description 1

zoneInductance · optionalITE public NTCIP working repository MIBs, NTCIP published standard MIB annexes (reviewed modules)2 sources

Status in source: optional.

Names: zoneInductance

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "zoneInductance",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "65535",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "optional",
    "DESCRIPTION",
    "\"<Definition> The detector unit calculates the inductance of the loop attached to the zone. The resolution is in tenths of a microHenry. For example, 852.4 microHenries is represented as 8524. Resolution does not imply accuracy, refer to manufacturers' data sheet. A value of 65535 shall be returned to represent invalid data or not a physical zone. <Unit> tenths of a microHenry <Object Identifier> 1.3.6.1.4.1.1206.4.2.4.4.3.1.1\"",
    "::=",
    "{",
    "loopSystemStatusEntry",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            65535
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "optional"
    ],
    [
      "DESCRIPTION",
      "<Definition> The detector unit calculates the inductance of the loop attached to the zone. The resolution is in tenths of a microHenry. For example, 852.4 microHenries is represented as 8524. Resolution does not imply accuracy, refer to manufacturers' data sheet. A value of 65535 shall be returned to represent invalid data or not a physical zone. <Unit> tenths of a microHenry <Object Identifier> 1.3.6.1.4.1.1206.4.2.4.4.3.1.1"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (5)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.4.4.3.1.2 zoneFrequency00
1.3.6.1.4.1.1206.4.2.4.4.3.1.3 zoneInductanceChange00
1.3.6.1.4.1.1206.4.2.4.4.3.1.4 zoneFaultHistory00
1.3.6.1.4.1.1206.4.2.4.4.3.1.5 zoneFaultCount00
1.3.6.1.4.1.1206.4.2.4.4.3.1.6 zonePercentInductanceChange00