OID reference

zoneInductanceChange

1.3.6.1.4.1.1206.4.2.4.4.3.1.3

Description

<Definition> The maximum inductance change seen since the last start of sensor zone occupancy is returned. The resolution is to one nanoHenry. Resolution does not imply accuracy. <Unit> nanoHenry <Object Identifier> 1.3.6.1.4.1.1206.4.2.4.4.3.1.3

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.4.4.3.1 (loopSystemStatusEntry)
Node code
3
Node name
zoneInductanceChange
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.4.4.3.1.3
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.4.4.3.1.3
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 4 4 3 1 3}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductanceChange(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductanceChange(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductanceChange(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductanceChange(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductanceChange(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductanceChange(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductanceChange(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductanceChange(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductanceChange(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductanceChange(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductanceChange(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductanceChange(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductanceChange(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductanceChange(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductanceChange(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) tss(4) tssInductiveLoop(4) loopSystemStatusTable(3) loopSystemStatusEntry(1) zoneInductanceChange(3)}
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/4/4/3/1/3
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/4/4/3/1/3
  • /ISO/3/6/1/4/1/1206/4/2/4/4/3/1/3
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductanceChange
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductanceChange
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductanceChange
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductanceChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductanceChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductanceChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductanceChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductanceChange
  • /iso/org/dod/internet/private/enterprise/1206/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductanceChange
  • /iso/org/dod/internet/private/enterprise/nema/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductanceChange
  • /iso/org/dod/internet/private/enterprises/1206/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductanceChange
  • /iso/org/dod/internet/private/enterprises/nema/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductanceChange
  • /iso/org/dod/internet/private/ldap-enterprise/1206/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductanceChange
  • /iso/org/dod/internet/private/ldap-enterprise/nema/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductanceChange
  • /iso/org/dod/internet/private/vendor-objects/1206/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductanceChange
  • /iso/org/dod/internet/private/vendor-objects/nema/transportation/devices/tss/tssInductiveLoop/loopSystemStatusTable/loopSystemStatusEntry/zoneInductanceChange
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
optional
Allowed ranges
0–8388608

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In NTCIP1209v02-MIB1, the row index sensorZoneNumber is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.1206.4.2.4.4.3.1.3.<sensorZoneNumber>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.4.4.3.1.3

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

zoneInductanceChange · optional

zoneInductanceChange  OBJECT-TYPE
SYNTAX  INTEGER (0..8388608)
ACCESS  read-only
STATUS  optional
DESCRIPTION  
"<Definition> The maximum inductance change seen since the last start of sensor zone occupancy is returned. The resolution is to one nanoHenry. Resolution does not imply accuracy.
<Unit> nanoHenry
<Object Identifier> 1.3.6.1.4.1.1206.4.2.4.4.3.1.3"
::= { loopSystemStatusEntry 3 }

zoneInductanceChange · optional

zoneInductanceChange OBJECT-TYPE
SYNTAX INTEGER (0..8388608)
ACCESS read-only
STATUS optional
DESCRIPTION
"<Definition> The maximum inductance change seen since the last start of
sensor zone occupancy is returned. The resolution is to one nanoHenry.
Resolution does not imply accuracy.
<Unit> nanoHenry
<Object Identifier> 1.3.6.1.4.1.1206.4.2.4.4.3.1.3"
::= { loopSystemStatusEntry 3 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

<Definition> The maximum inductance change seen since the last start of sensor zone occupancy is returned. The resolution is to one nanoHenry. Resolution does not imply accuracy. <Unit> nanoHenry <Object Identifier> 1.3.6.1.4.1.1206.4.2.4.4.3.1.3

Sources for this description

ITE public NTCIP working repository MIBsNTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1ITE public NTCIP working repository MIBs, NTCIP published standard MIB annexes (reviewed modules)1 record · 2 sources

Description 1

zoneInductanceChange · optionalITE public NTCIP working repository MIBs, NTCIP published standard MIB annexes (reviewed modules)2 sources

Status in source: optional.

Names: zoneInductanceChange

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "zoneInductanceChange",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "8388608",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "optional",
    "DESCRIPTION",
    "\"<Definition> The maximum inductance change seen since the last start of sensor zone occupancy is returned. The resolution is to one nanoHenry. Resolution does not imply accuracy. <Unit> nanoHenry <Object Identifier> 1.3.6.1.4.1.1206.4.2.4.4.3.1.3\"",
    "::=",
    "{",
    "loopSystemStatusEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            8388608
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "optional"
    ],
    [
      "DESCRIPTION",
      "<Definition> The maximum inductance change seen since the last start of sensor zone occupancy is returned. The resolution is to one nanoHenry. Resolution does not imply accuracy. <Unit> nanoHenry <Object Identifier> 1.3.6.1.4.1.1206.4.2.4.4.3.1.3"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (5)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.4.4.3.1.1 zoneInductance00
1.3.6.1.4.1.1206.4.2.4.4.3.1.2 zoneFrequency00
1.3.6.1.4.1.1206.4.2.4.4.3.1.4 zoneFaultHistory00
1.3.6.1.4.1.1206.4.2.4.4.3.1.5 zoneFaultCount00
1.3.6.1.4.1.1206.4.2.4.4.3.1.6 zonePercentInductanceChange00