OID reference

essTypeofStation

1.3.6.1.4.1.1206.4.2.5.1.2.1

Description

<Definition>Integer value that indicates the type of station. If the station is a hybrid station, it shall be defined as two stations, one staffed and one automatic. <Informative>The value of 2 has been explicitly defined as being reserved. To be defined as two stations (e.g., for a hybrid), a station needs to have tw…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.5.1.2 (essBufrInstrumentation)
Node code
1
Node name
essTypeofStation
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.5.1.2.1
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.5.1.2.1
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 5 1 2 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) ess(5) essBufr(1) essBufrInstrumentation(2) essTypeofStation(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) ess(5) essBufr(1) essBufrInstrumentation(2) essTypeofStation(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) ess(5) essBufr(1) essBufrInstrumentation(2) essTypeofStation(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) ess(5) essBufr(1) essBufrInstrumentation(2) essTypeofStation(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) ess(5) essBufr(1) essBufrInstrumentation(2) essTypeofStation(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) ess(5) essBufr(1) essBufrInstrumentation(2) essTypeofStation(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) ess(5) essBufr(1) essBufrInstrumentation(2) essTypeofStation(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) ess(5) essBufr(1) essBufrInstrumentation(2) essTypeofStation(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) ess(5) essBufr(1) essBufrInstrumentation(2) essTypeofStation(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) ess(5) essBufr(1) essBufrInstrumentation(2) essTypeofStation(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) ess(5) essBufr(1) essBufrInstrumentation(2) essTypeofStation(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) ess(5) essBufr(1) essBufrInstrumentation(2) essTypeofStation(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) ess(5) essBufr(1) essBufrInstrumentation(2) essTypeofStation(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) ess(5) essBufr(1) essBufrInstrumentation(2) essTypeofStation(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) ess(5) essBufr(1) essBufrInstrumentation(2) essTypeofStation(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) ess(5) essBufr(1) essBufrInstrumentation(2) essTypeofStation(1)}
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/5/1/2/1
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/5/1/2/1
  • /ISO/3/6/1/4/1/1206/4/2/5/1/2/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/ess/essBufr/essBufrInstrumentation/essTypeofStation
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/ess/essBufr/essBufrInstrumentation/essTypeofStation
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/ess/essBufr/essBufrInstrumentation/essTypeofStation
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/ess/essBufr/essBufrInstrumentation/essTypeofStation
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/ess/essBufr/essBufrInstrumentation/essTypeofStation
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/ess/essBufr/essBufrInstrumentation/essTypeofStation
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/ess/essBufr/essBufrInstrumentation/essTypeofStation
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/ess/essBufr/essBufrInstrumentation/essTypeofStation
  • /iso/org/dod/internet/private/enterprise/1206/transportation/devices/ess/essBufr/essBufrInstrumentation/essTypeofStation
  • /iso/org/dod/internet/private/enterprise/nema/transportation/devices/ess/essBufr/essBufrInstrumentation/essTypeofStation
  • /iso/org/dod/internet/private/enterprises/1206/transportation/devices/ess/essBufr/essBufrInstrumentation/essTypeofStation
  • /iso/org/dod/internet/private/enterprises/nema/transportation/devices/ess/essBufr/essBufrInstrumentation/essTypeofStation
  • /iso/org/dod/internet/private/ldap-enterprise/1206/transportation/devices/ess/essBufr/essBufrInstrumentation/essTypeofStation
  • /iso/org/dod/internet/private/ldap-enterprise/nema/transportation/devices/ess/essBufr/essBufrInstrumentation/essTypeofStation
  • /iso/org/dod/internet/private/vendor-objects/1206/transportation/devices/ess/essBufr/essBufrInstrumentation/essTypeofStation
  • /iso/org/dod/internet/private/vendor-objects/nema/transportation/devices/ess/essBufr/essBufrInstrumentation/essTypeofStation
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
mandatory
Allowed ranges
0–3

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.5.1.2.1.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 5 distinct definitions; some records may not include a definition.

Show 5 published definitions

essTypeofStation · mandatory

essTypeofStation OBJECT-TYPE
SYNTAX       INTEGER (0..3)
ACCESS       read-only
STATUS       mandatory
DESCRIPTION "<Definition>Integer value that indicates the type of station. If
the station is a hybrid station, it shall be defined as two stations, one
staffed and one automatic.
<Informative>The value of 2 has been explicitly defined as being reserved. To
be defined as two stations (e.g., for a hybrid), a station needs to have two
addresses and two instances of this MIB.
<SetConstraint>read-only
<DescriptiveName>ESS.typeOfStation:code
<Valid Value Rule>
value                  description
0 - automatic         the data is collected electronically/mechanically
1 - staffed           the data is collected by humans
2 - reserved
3 - missingValue      the type of station is unknown.
<Data Concept Type>Data Element"
REFERENCE    "WMO Binary Code Form FM 94 BUFR Table B item 0 02 001"
::=   { essBufrInstrumentation 1 }

essTypeofStation · mandatory

essTypeofStation OBJECT-TYPE
                        SYNTAX INTEGER (0..3)
ACCESS            read-only
STATUS            mandatory
DESCRIPTION “Integer value that indicates the type of station. If the station is a hybrid station, it shall be
defined as two stations, one staffed and one automatic.
      value                      description
      0 - automatic              the data is collected electronically/mechanically
      1 - staffed                the data is collected by humans
      3 - missingValue           the type of station is unknown.”
REFERENCE “WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 02 001.”
::= {essBufrInstrumentation 1}

essTypeofStation · mandatory

essTypeofStation OBJECT-TYPE
SYNTAX       INTEGER (0..3)
ACCESS       read-only
STATUS       mandatory
DESCRIPTION "<Definition>Integer value that indicates the type of station.
If the station is a hybrid station, it shall be defined as two stations, one
staffed and one automatic.
<SetConstraint>read-only
<DescriptiveName>ESS.typeOfStation:code
<Valid Value Rule>
value                  description
0 - automatic         the data is collected electronically/mechanically
1 - staffed           the data is collected by humans
3 - missingValue      the type of station is unknown.
<Data Concept Type>Data Element"
REFERENCE    "WMO Binary Code Form FM 94 BUFR Table B item 0 02 001"
::=   { essBufrInstrumentation 1 }

essTypeofStation · mandatory

essTypeofStation OBJECT-TYPE
SYNTAX	INTEGER (0..3) 
ACCESS	read-only 
STATUS	mandatory 
DESCRIPTION "<Definition>Integer value that indicates the type of station. If the station is a hybrid station, it shall be defined as two stations, one staffed and one automatic.
<Informative>The value of 2 has been explicitly defined as being reserved. To be defined as two stations (e.g., for a hybrid), a station needs to have two addresses and two instances of this MIB.
<DescriptiveName>ESS.typeOfStation:code
<Valid Value Rule>	
value               description 
0 - automatic      the data is collected electronically/mechanically 
1 - staffed        the data is collected by humans 
2 - reserved
3 - missingValue   the type of station is unknown.
<Data Concept Type>Data Element
<Object Identifier> 1.3.6.1.4.1.1206.4.2.5.1.2.1"
REFERENCE	"WMO Binary Code Form FM 94 BUFR Table B item 0 02 001"
::=	{ essBufrInstrumentation 1 }

essTypeofStation · mandatory

essTypeofStation OBJECT-TYPE
SYNTAX       INTEGER (0..3)
ACCESS       read-only
STATUS       mandatory
DESCRIPTION "<Definition>Integer value that indicates the type of station. If
the station is a hybrid station, it shall be defined as two stations, one
staffed and one automatic.
<Informative>The value of 2 has been explicitly defined as being reserved. To
be defined as two stations (e.g., for a hybrid), a station needs to have two
addresses and two instances of this MIB.
<DescriptiveName>ESS.typeOfStation:code
<Valid Value Rule>
value                description
0 - automatic       the data is collected electronically/mechanically
1 - staffed         the data is collected by humans
2 - reserved
3 - missingValue    the type of station is unknown.
<Data Concept Type>Data Element
<Object Identifier> 1.3.6.1.4.1.1206.4.2.5.1.2.1"
REFERENCE    "WMO Binary Code Form FM 94 BUFR Table B item 0 02 001"
::=    { essBufrInstrumentation 1 }

Meaning

Descriptions

4 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

<Definition>Integer value that indicates the type of station. If the station is a hybrid station, it shall be defined as two stations, one staffed and one automatic. <Informative>The value of 2 has been explicitly defined as being reserved. To be defined as two stations (e.g., for a hybrid), a station needs to have two addresses and two instances of this MIB. <SetConstraint>read-only <DescriptiveName>ESS.typeOfStation:code <Valid Value Rule> value description 0 - automatic the data is collected electronically/mechanically 1 - staffed the data is collected by humans 2 - reserved 3 - missingValue the type of station is unknown. <Data Concept Type>Data Element

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 2

Integer value that indicates the type of station. If the station is a hybrid station, it shall be defined as two stations, one staffed and one automatic. value description 0 - automatic the data is collected electronically/mechanically 1 - staffed the data is collected by humans 3 - missingValue the type of station is unknown.

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 3

<Definition>Integer value that indicates the type of station. If the station is a hybrid station, it shall be defined as two stations, one staffed and one automatic. <SetConstraint>read-only <DescriptiveName>ESS.typeOfStation:code <Valid Value Rule> value description 0 - automatic the data is collected electronically/mechanically 1 - staffed the data is collected by humans 3 - missingValue the type of station is unknown. <Data Concept Type>Data Element

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 4

<Definition>Integer value that indicates the type of station. If the station is a hybrid station, it shall be defined as two stations, one staffed and one automatic. <Informative>The value of 2 has been explicitly defined as being reserved. To be defined as two stations (e.g., for a hybrid), a station needs to have two addresses and two instances of this MIB. <DescriptiveName>ESS.typeOfStation:code <Valid Value Rule> value description 0 - automatic the data is collected electronically/mechanically 1 - staffed the data is collected by humans 2 - reserved 3 - missingValue the type of station is unknown. <Data Concept Type>Data Element <Object Identifier> 1.3.6.1.4.1.1206.4.2.5.1.2.1

Sources for this description

ITE public NTCIP working repository MIBsNTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

4 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 1

essTypeofStation · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: essTypeofStation

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "essTypeofStation",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "3",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition>Integer value that indicates the type of station. If the station is a hybrid station, it shall be defined as two stations, one staffed and one automatic. <Informative>The value of 2 has been explicitly defined as being reserved. To be defined as two stations (e.g., for a hybrid), a station needs to have two addresses and two instances of this MIB. <SetConstraint>read-only <DescriptiveName>ESS.typeOfStation:code <Valid Value Rule> value description 0 - automatic the data is collected electronically/mechanically 1 - staffed the data is collected by humans 2 - reserved 3 - missingValue the type of station is unknown. <Data Concept Type>Data Element\"",
    "REFERENCE",
    "\"WMO Binary Code Form FM 94 BUFR Table B item 0 02 001\"",
    "::=",
    "{",
    "essBufrInstrumentation",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition>Integer value that indicates the type of station. If the station is a hybrid station, it shall be defined as two stations, one staffed and one automatic. <Informative>The value of 2 has been explicitly defined as being reserved. To be defined as two stations (e.g., for a hybrid), a station needs to have two addresses and two instances of this MIB. <SetConstraint>read-only <DescriptiveName>ESS.typeOfStation:code <Valid Value Rule> value description 0 - automatic the data is collected electronically/mechanically 1 - staffed the data is collected by humans 2 - reserved 3 - missingValue the type of station is unknown. <Data Concept Type>Data Element"
    ],
    [
      "REFERENCE",
      "WMO Binary Code Form FM 94 BUFR Table B item 0 02 001"
    ],
    null,
    null,
    null
  ]
}
Records for description 2NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 2

essTypeofStation · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: essTypeofStation

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "essTypeofStation",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "3",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "“",
    "Integer",
    "value",
    "that",
    "indicates",
    "the",
    "type",
    "of",
    "station",
    ".",
    "If",
    "the",
    "station",
    "is",
    "a",
    "hybrid",
    "station",
    ",",
    "it",
    "shall",
    "be",
    "defined",
    "as",
    "two",
    "stations",
    ",",
    "one",
    "staffed",
    "and",
    "one",
    "automatic",
    ".",
    "value",
    "description",
    "0",
    "-",
    "automatic",
    "the",
    "data",
    "is",
    "collected",
    "electronically",
    "/",
    "mechanically",
    "1",
    "-",
    "staffed",
    "the",
    "data",
    "is",
    "collected",
    "by",
    "humans",
    "3",
    "-",
    "missingValue",
    "the",
    "type",
    "of",
    "station",
    "is",
    "unknown",
    ".",
    "”",
    "REFERENCE",
    "“",
    "WMO",
    "Binary",
    "Code",
    "form",
    "FM",
    "94",
    "BUFR",
    "Table",
    "B",
    "table",
    "reference",
    "descriptor",
    "0",
    "02",
    "001",
    ".",
    "”",
    "::=",
    "{",
    "essBufrInstrumentation",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Integer value that indicates the type of station. If the station is a hybrid station, it shall be defined as two stations, one staffed and one automatic. value description 0 - automatic the data is collected electronically/mechanically 1 - staffed the data is collected by humans 3 - missingValue the type of station is unknown."
    ],
    [
      "REFERENCE",
      "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 02 001."
    ],
    null,
    null,
    null
  ]
}
  • NTCIP published standard MIB annexes (reviewed modules) · Publisher's source file: NTCIP 1204:1998, Object Definitions for Environmental Sensor Stations (ESS) Published November 2001 (superceded by NTCIP 1204 v02) — original PDF · Official record

    Module: ESS-MIB

    See published definition above

    Module imports
    {'TMIB': ['devices'], 'NEMA_SMI': ['experimental'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['IpAddress', 'Counter'], 'RFC1158-SMI': ['DisplayString']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.

    Source data warning: A typographic closing DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.

    Source data warning: A typographic opening DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: TMIB. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP1204v0113c.pdf — ESS-MIB (MIB transcription)
Records for description 3NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 3

essTypeofStation · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: essTypeofStation

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "essTypeofStation",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "3",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition>Integer value that indicates the type of station. If the station is a hybrid station, it shall be defined as two stations, one staffed and one automatic. <SetConstraint>read-only <DescriptiveName>ESS.typeOfStation:code <Valid Value Rule> value description 0 - automatic the data is collected electronically/mechanically 1 - staffed the data is collected by humans 3 - missingValue the type of station is unknown. <Data Concept Type>Data Element\"",
    "REFERENCE",
    "\"WMO Binary Code Form FM 94 BUFR Table B item 0 02 001\"",
    "::=",
    "{",
    "essBufrInstrumentation",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition>Integer value that indicates the type of station. If the station is a hybrid station, it shall be defined as two stations, one staffed and one automatic. <SetConstraint>read-only <DescriptiveName>ESS.typeOfStation:code <Valid Value Rule> value description 0 - automatic the data is collected electronically/mechanically 1 - staffed the data is collected by humans 3 - missingValue the type of station is unknown. <Data Concept Type>Data Element"
    ],
    [
      "REFERENCE",
      "WMO Binary Code Form FM 94 BUFR Table B item 0 02 001"
    ],
    null,
    null,
    null
  ]
}
Records for description 4ITE public NTCIP working repository MIBs, NTCIP published standard MIB annexes (reviewed modules)1 record · 2 sources

Description 4

essTypeofStation · mandatoryITE public NTCIP working repository MIBs, NTCIP published standard MIB annexes (reviewed modules)2 sources

Status in source: mandatory.

Names: essTypeofStation

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "essTypeofStation",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "3",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition>Integer value that indicates the type of station. If the station is a hybrid station, it shall be defined as two stations, one staffed and one automatic. <Informative>The value of 2 has been explicitly defined as being reserved. To be defined as two stations (e.g., for a hybrid), a station needs to have two addresses and two instances of this MIB. <DescriptiveName>ESS.typeOfStation:code <Valid Value Rule> value description 0 - automatic the data is collected electronically/mechanically 1 - staffed the data is collected by humans 2 - reserved 3 - missingValue the type of station is unknown. <Data Concept Type>Data Element <Object Identifier> 1.3.6.1.4.1.1206.4.2.5.1.2.1\"",
    "REFERENCE",
    "\"WMO Binary Code Form FM 94 BUFR Table B item 0 02 001\"",
    "::=",
    "{",
    "essBufrInstrumentation",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition>Integer value that indicates the type of station. If the station is a hybrid station, it shall be defined as two stations, one staffed and one automatic. <Informative>The value of 2 has been explicitly defined as being reserved. To be defined as two stations (e.g., for a hybrid), a station needs to have two addresses and two instances of this MIB. <DescriptiveName>ESS.typeOfStation:code <Valid Value Rule> value description 0 - automatic the data is collected electronically/mechanically 1 - staffed the data is collected by humans 2 - reserved 3 - missingValue the type of station is unknown. <Data Concept Type>Data Element <Object Identifier> 1.3.6.1.4.1.1206.4.2.5.1.2.1"
    ],
    [
      "REFERENCE",
      "WMO Binary Code Form FM 94 BUFR Table B item 0 02 001"
    ],
    null,
    null,
    null
  ]
}
  • ITE public NTCIP working repository MIBs · Publisher's source file: NTCIP-1204 — NTCIP1204-Ess.mib

    Module: NTCIP1204-v04

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString'], 'NTCIP8004v02': ['ess', 'OerString']}

    Source data warning: This original is published in an ITE NTCIP working repository. Repository publication does not establish that this particular revision is an adopted standard. Consult its native revision history and the NTCIP published standards catalog before implementation. Copyright and distribution notices are retained in the downloadable original.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP imports: the original references NTCIP8004v02, which is absent from the public repository snapshot. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP-1204 — NTCIP1204-Ess.mib
  • NTCIP published standard MIB annexes (reviewed modules) · Publisher's source file: NTCIP 1204 v0426, National Transportation Communications for ITS Protocol Environmental Sensor Station (ESS) Interface Protocol — original PDF · Official record

    Module: NTCIP1204-v04

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString'], 'NTCIP8004v02': ['ess', 'OerString']}

    Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.

    Source data warning: The published normative SMI section omits its module END. The derived parser boundary is placed immediately before section 5.17, whose text explicitly says its items are not SNMP Objects. No declaration or numeric arc is added; the complete PDF is authoritative.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: NTCIP8004v02. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP-1204v0426b-2021_AsPublished.pdf — NTCIP1204-v04 (MIB transcription)

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.