The target temperature is the average temperature we would like the
system to operate at if possible. It is used to calculate how long the fans
should stay on during a cycle which is part of a duty cycle algorithm.
Temperature is in degrees celsius.
Parsed from file amperion.mib.txt
Company: None
Module: Amperion-MIB
The target temperature is the average temperature we would like the
system to operate at if possible. It is used to calculate how long the fans
should stay on during a cycle which is part of a duty cycle algorithm.
Temperature is in degrees celsius.
Parsed from file Amperion-MIB.mib
Module: Amperion-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
tempFanTargetTemp OBJECT-TYPE SYNTAX Integer32(0..70) UNITS "degrees celcius" MAX-ACCESS read-write STATUS current DESCRIPTION "The target temperature is the average temperature we would like the system to operate at if possible. It is used to calculate how long the fans should stay on during a cycle which is part of a duty cycle algorithm. Temperature is in degrees celsius." DEFVAL { 25 } ::= { tempGroup 2 }
tempFanTargetTemp OBJECT-TYPE SYNTAX Integer32(0..70) UNITS "degrees celcius" MAX-ACCESS read-write STATUS current DESCRIPTION "The target temperature is the average temperature we would like the system to operate at if possible. It is used to calculate how long the fans should stay on during a cycle which is part of a duty cycle algorithm. Temperature is in degrees celsius." DEFVAL { 25 } ::= { tempGroup 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.13995.12.2.0 | tempFanTargetTemp | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.13995.12.1 | tempFanState | 1 | 1 | The fans may be on or off. |
1.3.6.1.4.1.13995.12.3 | tempHighWarnLimit | 1 | 1 | The system temperature has exceeded a high temperature warning threshold. Temperature is in degrees Celsius. |
1.3.6.1.4.1.13995.12.4 | tempHighWarnLimitTrap | 0 | 0 | The system temperature has exceeded the High Warning threshold. |
1.3.6.1.4.1.13995.12.5 | tempEventDescription | 1 | 1 | String to be sent with the temperature trap events. |
1.3.6.1.4.1.13995.12.6 | tempHighErrorLimitTrap | 0 | 0 | The system temperature has exceeded the High Error Threshold. |
1.3.6.1.4.1.13995.12.7 | tempLowWarnLimitTrap | 0 | 0 | The system temperature has gone below the Low Warning Threshold. |
1.3.6.1.4.1.13995.12.8 | tempLowErrorLimitTrap | 0 | 0 | The system temperature has gone below the Low Error Threshold. |
1.3.6.1.4.1.13995.12.9 | tempHighErrorLimit | 1 | 1 | The system temperature has exceeded a high temperature error threshold. Temperature is in degrees Celsius. |
1.3.6.1.4.1.13995.12.10 | tempLowWarnLimit | 1 | 1 | The system temperature has gone below a low temperature warning threshold. Temperature is in degrees Celscius. |
1.3.6.1.4.1.13995.12.11 | tempLowErrorLimit | 1 | 1 | The system temperature has gone below the Low Temperature Error Threshold. The temperature is in degrees Celscius. |
1.3.6.1.4.1.13995.12.12 | tempHighWarnHist | 1 | 1 | Hysteresis value for the High Temperature Warning Condition. Once the system temperature has reached or exceeded the High Temper… |
1.3.6.1.4.1.13995.12.13 | tempHighErrorHist | 1 | 1 | Hysteresis value for the High Temperature Error Condition. Once the system temperature has reached or exceeded the High Temperat… |
1.3.6.1.4.1.13995.12.14 | tempLowWarnHist | 1 | 1 | Hysteresis value for the Low Temperature Warning Condition. Once the system temperature is less than or equal to the LowTemperat… |
1.3.6.1.4.1.13995.12.15 | tempLowErrorHist | 1 | 1 | Hysteresis value for the Low Temperature Error Condition. Once the system temperature is less than or equal to the LowTemperatur… |
1.3.6.1.4.1.13995.12.16 | tempSystemTemp | 1 | 1 | The temperature of the Main Digital Board. The temperature is obtained by reading a chip located on the digital board. |