Reference record for OID 1.3.6.1.4.1.13995.12.9


parent
1.3.6.1.4.1.13995.12 (tempGroup)
node code
9
node name
tempHighErrorLimit
dot oid
1.3.6.1.4.1.13995.12.9
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) amperion(13995) tempGroup(12) tempHighErrorLimit(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) amperion(13995) tempGroup(12) tempHighErrorLimit(9)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) amperion(13995) tempGroup(12) tempHighErrorLimit(9)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) amperion(13995) tempGroup(12) tempHighErrorLimit(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) amperion(13995) tempGroup(12) tempHighErrorLimit(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) amperion(13995) tempGroup(12) tempHighErrorLimit(9)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/amperion/tempGroup/tempHighErrorLimit
  • /iso/identified-organization/dod/internet/private/enterprises/amperion/tempGroup/tempHighErrorLimit
  • /iso/org/dod/internet/private/enterprise/amperion/tempGroup/tempHighErrorLimit
  • /iso/org/dod/internet/private/enterprises/amperion/tempGroup/tempHighErrorLimit
  • /iso/iso-identified-organization/dod/internet/private/enterprise/amperion/tempGroup/tempHighErrorLimit
  • /iso/iso-identified-organization/dod/internet/private/enterprises/amperion/tempGroup/tempHighErrorLimit
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/13995/12/9

    Description by mibdepot

    The system temperature has exceeded a high temperature error threshold.

    Temperature is in degrees Celsius.

    Parsed from file amperion.mib.txt
    Company: None
    Module: Amperion-MIB

    Description by circitor

    The system temperature has exceeded a high temperature error threshold.

    Temperature is in degrees Celsius.

    Parsed from file Amperion-MIB.mib
    Module: Amperion-MIB

    Information by oid_info

    Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.

    Information by mibdepot

    tempHighErrorLimit OBJECT-TYPE SYNTAX Integer32(0..150) UNITS "degrees Celscius" MAX-ACCESS read-write STATUS current DESCRIPTION "The system temperature has exceeded a high temperature error threshold. Temperature is in degrees Celsius." DEFVAL { 100 } ::= { tempGroup 9 }

    Information by circitor

    tempHighErrorLimit OBJECT-TYPE SYNTAX Integer32(0..150) UNITS "degrees Celscius" MAX-ACCESS read-write STATUS current DESCRIPTION "The system temperature has exceeded a high temperature error threshold. Temperature is in degrees Celsius." DEFVAL { 100 } ::= { tempGroup 9 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.13995)

    Brothwell Jay

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.13995.12.9.0 tempHighErrorLimit 0 0 None

    Brothers (15)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.13995.12.1 tempFanState 1 1 The fans may be on or off.
    1.3.6.1.4.1.13995.12.2 tempFanTargetTemp 1 1 The target temperature is the average temperature we would like the
    system to operate at if possible. It is used to calculate ho…
    1.3.6.1.4.1.13995.12.3 tempHighWarnLimit 1 1 The system temperature has exceeded a high temperature warning threshold.

    Temperature is in degrees Celsius.
    1.3.6.1.4.1.13995.12.4 tempHighWarnLimitTrap 0 0 The system temperature has exceeded the High Warning threshold.
    1.3.6.1.4.1.13995.12.5 tempEventDescription 1 1 String to be sent with the temperature trap events.
    1.3.6.1.4.1.13995.12.6 tempHighErrorLimitTrap 0 0 The system temperature has exceeded the High Error Threshold.
    1.3.6.1.4.1.13995.12.7 tempLowWarnLimitTrap 0 0 The system temperature has gone below the Low Warning Threshold.
    1.3.6.1.4.1.13995.12.8 tempLowErrorLimitTrap 0 0 The system temperature has gone below the Low Error Threshold.
    1.3.6.1.4.1.13995.12.10 tempLowWarnLimit 1 1 The system temperature has gone below a low temperature warning threshold.

    Temperature is in degrees Celscius.
    1.3.6.1.4.1.13995.12.11 tempLowErrorLimit 1 1 The system temperature has gone below the Low Temperature Error Threshold.

    The temperature is in degrees Celscius.
    1.3.6.1.4.1.13995.12.12 tempHighWarnHist 1 1 Hysteresis value for the High Temperature Warning Condition. Once the
    system temperature has reached or exceeded the High Temper…
    1.3.6.1.4.1.13995.12.13 tempHighErrorHist 1 1 Hysteresis value for the High Temperature Error Condition. Once the
    system temperature has reached or exceeded the High Temperat…
    1.3.6.1.4.1.13995.12.14 tempLowWarnHist 1 1 Hysteresis value for the Low Temperature Warning Condition. Once the
    system temperature is less than or equal to the LowTemperat…
    1.3.6.1.4.1.13995.12.15 tempLowErrorHist 1 1 Hysteresis value for the Low Temperature Error Condition. Once the
    system temperature is less than or equal to the LowTemperatur…
    1.3.6.1.4.1.13995.12.16 tempSystemTemp 1 1 The temperature of the Main Digital Board. The temperature is obtained
    by reading a chip located on the digital board.