Hour when exclusion period ends. For example, a value of
23 means that the exclusion ends at 11 p.m.
The maximum duration of an exclusion period can be 24 hours.
If dptScsiHbaExclusionPeriodStart is greater than
dptScsiHbaExclusionPeriodEnd, it means that the exclusions
period extends over the next day.
HBA exclution period is the time span during which it devotes
100% of its time fulfilling requests for data reads/writes
and zero percent on background activities like build/rebuild
of arrays.
Parsed from file Dpt.mib.txt
Company: None
Module: DPT-SCSI-MIB
Hour when exclusion period ends. For example, a value of
23 means that the exclusion ends at 11 p.m.
The maximum duration of an exclusion period can be 24 hours.
If dptScsiHbaExclusionPeriodStart is greater than
dptScsiHbaExclusionPeriodEnd, it means that the exclusions
period extends over the next day.
Contoller exclution period is the time span during which it
devotes 100% of its time fulfilling requests for data
reads/writes and zero percent on background activities like
build/rebuild of arrays.
Parsed from file DPT-SCSI-MIB.mib
Module: DPT-SCSI-MIB
Vendor: Distributed Processing Technology
Module: DPT-SCSI-MIB
[Automatically extracted from oidview.com]
dptScsiHbaExclusionPeriodEnd OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-only STATUS mandatory DESCRIPTION "Hour when exclusion period ends. For example, a value of 23 means that the exclusion ends at 11 p.m. The maximum duration of an exclusion period can be 24 hours. If dptScsiHbaExclusionPeriodStart is greater than dptScsiHbaExclusionPeriodEnd, it means that the exclusions period extends over the next day. HBA exclution period is the time span during which it devotes 100% of its time fulfilling requests for data reads/writes and zero percent on background activities like build/rebuild of arrays." ::= { dptScsiHbaEntry 20 }
dptScsiHbaExclusionPeriodEnd OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-only STATUS deprecated DESCRIPTION "Hour when exclusion period ends. For example, a value of 23 means that the exclusion ends at 11 p.m. The maximum duration of an exclusion period can be 24 hours. If dptScsiHbaExclusionPeriodStart is greater than dptScsiHbaExclusionPeriodEnd, it means that the exclusions period extends over the next day. Contoller exclution period is the time span during which it devotes 100% of its time fulfilling requests for data reads/writes and zero percent on background activities like build/rebuild of arrays." ::= { dptScsiHbaEntry 20 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1597.1.2.1.1.1 | dptScsiHbaNumber | 0 | 0 | An index that uniquely identifies a row in dptHbaTable that pertains to a particular controller. The value of this object is the … |
1.3.6.1.4.1.1597.1.2.1.1.2 | dptScsiHbaVendor | 0 | 0 | The name of the vendor of the HBA. |
1.3.6.1.4.1.1597.1.2.1.1.3 | dptScsiHbaModel | 0 | 0 | The controller model identifier. |
1.3.6.1.4.1.1597.1.2.1.1.4 | dptScsiHbaFirmware | 0 | 0 | The controller firmware version. |
1.3.6.1.4.1.1597.1.2.1.1.5 | dptScsiHbaSerialNumber | 0 | 0 | The controller serial number. |
1.3.6.1.4.1.1597.1.2.1.1.6 | dptScsiHbaAddress, dptScsiHbaIOAddress | 0 | 0 | The controller Address (normally displayed in hex.) It is a 32-bit value representing the memory address used by the controller |
1.3.6.1.4.1.1597.1.2.1.1.7 | dptScsiHbaHostBusType | 0 | 0 | The type of the host computer's system bus this HBA is attached to. |
1.3.6.1.4.1.1597.1.2.1.1.8 | dptScsiHbaHostBusMaxTransferRate | 0 | 0 | The host bus maximum possible transfer rate in MB/s. |
1.3.6.1.4.1.1597.1.2.1.1.9 | dptScsiHbaIrq | 0 | 0 | The controller interrupt level. |
1.3.6.1.4.1.1597.1.2.1.1.10 | dptScsiHbaIrqType | 0 | 0 | The Host Bus Adapter(HBA) interrupt type. |
1.3.6.1.4.1.1597.1.2.1.1.11 | dptScsiHbaDrq | 0 | 0 | The Host Bus Adapter(HBA) DMA channel. This object is only applicable for ISA HBAs. Its value is 'notApplicable' for the other ty… |
1.3.6.1.4.1.1597.1.2.1.1.12 | dptScsiHbaRaidModule | 0 | 0 | The HBA RAID module type. The addition of a DM4000 RAID module and caching module (SmarCache III products) or an RC4040 or RC4041… |
1.3.6.1.4.1.1597.1.2.1.1.13 | dptScsiHbaCachingModule | 0 | 0 | The HBA caching module. 'Embedded' means that the disk array function is built inside the HBA (SmartRAID products.) |
1.3.6.1.4.1.1597.1.2.1.1.14 | dptScsiHbaAudibleAlarmOn | 0 | 0 | This returns the current status of the controller alarm. |
1.3.6.1.4.1.1597.1.2.1.1.15 | dptScsiHbaUpTime | 0 | 0 | Time elapsed (in hundredths of a second) since the controller was last booted. |
1.3.6.1.4.1.1597.1.2.1.1.16 | dptScsiHbaEccEnabled | 0 | 0 | Shows if ECC is enabled on the HBA. Setting this allows the enabling and disabling of ECC. |
1.3.6.1.4.1.1597.1.2.1.1.17 | dptScsiHbaBackgroundTaskPriority | 0 | 0 | This object controls the priority of background tasks such as diagnostics, array verification and array rebuilds for this HBA. Se… |
1.3.6.1.4.1.1597.1.2.1.1.18 | dptScsiHbaExclusionPeriodEnabled | 0 | 0 | HBA exclution period is the time span during which it devotes 100% of its time fulfilling requests for data reads/writes and zero… |
1.3.6.1.4.1.1597.1.2.1.1.19 | dptScsiHbaExclusionPeriodStart | 0 | 0 | Hour of beginning of the exclusion period. For example, a value of 0 means that the exclusion starts at 12 a.m. The maximum durat… |
1.3.6.1.4.1.1597.1.2.1.1.21 | dptScsiHbaMaxReadAheadPercentage | 0 | 0 | Max percentage of HBA cache RAM devoted to read-ahead pages. |
1.3.6.1.4.1.1597.1.2.1.1.22 | dptScsiHbaMaxDirtyPagesPercentage | 0 | 0 | Max percentage of HBA cache RAM that may contain dirty pages. |
1.3.6.1.4.1.1597.1.2.1.1.23 | dptScsiHbaWriteBackDelay | 0 | 0 | Write-back delay in milliseconds. |
1.3.6.1.4.1.1597.1.2.1.1.24 | dptScsiHbaTemperature | 0 | 0 | Temperature as measured by the HBA. |
1.3.6.1.4.1.1597.1.2.1.1.25 | dptScsiHbaVoltage | 0 | 0 | Voltage as measured by the HBA. |
1.3.6.1.4.1.1597.1.2.1.1.26 | dptScsiHbaBadMemoryAddress | 0 | 0 | If the controller detects a cache RAM error, the address of the most recent error is stored here. Otherwise it indicates that no … |
1.3.6.1.4.1.1597.1.2.1.1.27 | dptScsiHbaBatteryModule | 0 | 0 | The Battery Backup Module preserves all controller cache and local memory contents in the event of power loss to the system |
1.3.6.1.4.1.1597.1.2.1.1.28 | dptScsiHbaBatteryStatus | 0 | 0 | Battery status reported by the controller. |
1.3.6.1.4.1.1597.1.2.1.1.29 | dptScsiHbaHighestBusWithDevices | 0 | 0 | The bus number of the highest numbered bus on this controller which has devices currently attached to it. |
1.3.6.1.4.1.1597.1.2.1.1.30 | dptScsiHbaGeneralStatus | 0 | 0 | General controller status. The following are the possible values: ok - the controller and all components attached to… |
1.3.6.1.4.1.1597.1.2.1.1.31 | dptScsiHbaSmorSignature | 0 | 0 | The controller S.M.O.R. revision information. Not available for SmartRAID IV and earlier controllers. |
1.3.6.1.4.1.1597.1.2.1.1.32 | dptScsiHbaBiosSignature | 0 | 0 | The controller B.I.O.S. revision information. Not available for SmartRAID IV and earlier controllers. |
1.3.6.1.4.1.1597.1.2.1.1.33 | dptScsiHbaNvramLayout | 0 | 0 | The controller NVRAM layout revision. |