This object indicates the current date as it is known by the
agent using its own real-time clock. The format would be as
specified by the sysSDateFormat.
This parameter can be set for time synchronization between
the NMS and the Agent.
* For KM-2100 V1 and FCD-T1/E1 - the string should contain
'/' signs between day, month and year. Example: 12/08/1998.
* For DXC and rest of the products - the string should contain
'-' signs between day, month and year. Example: 12-08-1998.
The day value will be in the range: 1..31.
The month value will be in the range: 1..12.
The year value will be in the range: 1996..2050 for products
supporting the '-' format.
Parsed from file Rad0485.MIB.txt
Company: None
Module: RAD-MIB
This object indicates the current date as it is known by the
agent using its own real-time clock. The format would be as
specified by the sysSDateFormat.
This parameter can be set for time synchronization between
the NMS and the Agent.
* For KM-2100 V1 and FCD-T1/E1 - the string should contain
'/' signs between day, month and year. Example: 12/08/1998.
* For DXC and rest of the products - the string should contain
'-' signs between day, month and year. Example: 12-08-1998.
The day value will be in the range: 1..31.
The month value will be in the range: 1..12.
The year value will be in the range: 1996..2050 for products
supporting the '-' format.
Parsed from file RAD-MIB.mib
Module: RAD-MIB
Vendor: Rad Data Communications Ltd.
Module: DACS-MIB
[Automatically extracted from oidview.com]
sysSDateCmd OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the current date as it is known by the agent using its own real-time clock. The format would be as specified by the sysSDateFormat. This parameter can be set for time synchronization between the NMS and the Agent. * For KM-2100 V1 and FCD-T1/E1 - the string should contain '/' signs between day, month and year. Example: 12/08/1998. * For DXC and rest of the products - the string should contain '-' signs between day, month and year. Example: 12-08-1998. The day value will be in the range: 1..31. The month value will be in the range: 1..12. The year value will be in the range: 1996..2050 for products supporting the '-' format." ::= { sysStatus 2 }
sysSDateCmd OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the current date as it is known by the agent using its own real-time clock. The format would be as specified by the sysSDateFormat. This parameter can be set for time synchronization between the NMS and the Agent. * For KM-2100 V1 and FCD-T1/E1 - the string should contain '/' signs between day, month and year. Example: 12/08/1998. * For DXC and rest of the products - the string should contain '-' signs between day, month and year. Example: 12-08-1998. The day value will be in the range: 1..31. The month value will be in the range: 1..12. The year value will be in the range: 1996..2050 for products supporting the '-' format." ::= { sysStatus 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.3.3.1.3.2.0 | sysSDateCmd | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.3.3.1.3.1 | sysSDateFormat | 1 | 1 | This object indicates the date and time format used for the sysSDateAndTimeCmd and for the alarm buffer report. |
1.3.6.1.4.1.164.3.3.1.3.3 | sysSTimeCmd | 1 | 1 | This object indicates the current time as it is known by the agent using its own real-time clock. This parameter can be set for … |
1.3.6.1.4.1.164.3.3.1.3.4 | sysSActiveCnfg | 1 | 1 | This object specifies the configuration number, that is currently active and running. |
1.3.6.1.4.1.164.3.3.1.3.5 | sysSEditCnfg | 1 | 1 | This object indicates the unique configuration number that is currently loaded into the tmp working space for manipulation and … |
1.3.6.1.4.1.164.3.3.1.3.6 | sysSEditBy | 1 | 1 | This entry indicates which MMI application is working on the edited config. The editing phase starts at the first modify operatio… |
1.3.6.1.4.1.164.3.3.1.3.7 | sysSClkSrc | 1 | 1 | This entry indicates the source of the system clock. |
1.3.6.1.4.1.164.3.3.1.3.8 | sysSAlrStatus | 1 | 1 | Indicates the current alarm state only for system level. This object will be : - critical(7): when there is at least one active (… |
1.3.6.1.4.1.164.3.3.1.3.9 | sysSAlrStatusAll | 1 | 1 | Indicates the current alarm state including all levels: system, card, port. - critical(7): when there is at least one active (ON)… |
1.3.6.1.4.1.164.3.3.1.3.10 | sysSTestStatus | 1 | 1 | Indicates the current test status (for all levels: system, card, port). This attribute will be set to: - on(3): when there is at l… |
1.3.6.1.4.1.164.3.3.1.3.11 | sysSSanityCheckStatus | 1 | 1 | Upon completion of the Sanity Check process on the TmpCnfg this object will be set to: - fail(2): when there is at least one erro… |
1.3.6.1.4.1.164.3.3.1.3.12 | sysSNoOfSanityCheckErr | 1 | 1 | This object indicates the number of errors/warnings discovered by the last Sanity Check process. |
1.3.6.1.4.1.164.3.3.1.3.13 | sysSErrListTable | 1 | 4 | A table. |
1.3.6.1.4.1.164.3.3.1.3.14 | sysSMaxNoOfCnfg | 1 | 1 | Maximum number of configurations that can be defined and stored in the DACS agent. If the DACS agent has a large capacity, the ma… |
1.3.6.1.4.1.164.3.3.1.3.15 | sysSSelfTestResult | 1 | 1 | sysSSelftestResult |
1.3.6.1.4.1.164.3.3.1.3.16 | sysSRelayState | 1 | 1 | Indicates the current state of the alarm relay. notApplicable - for agents that do not support this object. |
1.3.6.1.4.1.164.3.3.1.3.17 | sysSInvertedAlr | 1 | 1 | Indicates if there is any Inverted alarm at any level of the system (sys, card, port). notApplicable - for agents that do not sup… |
1.3.6.1.4.1.164.3.3.1.3.18 | sysSRdnFlipTable | 1 | 7 | This table includes all the Flip events due to I/O Redundancy since last Clear command of this table. |
1.3.6.1.4.1.164.3.3.1.3.19 | sysSRdnFlipTableClearCmd | 1 | 1 | This command, when Set to 'on', clears the Redundancy Flip table (sysSRdnFlipTable). After clear is performed, the agent will tu… |
1.3.6.1.4.1.164.3.3.1.3.20 | sysSRdnFlipCmd | 1 | 1 | This object enables the user to send a command to the Agent, to Flip from a current Online IO card to its Redundant card. The val… |
1.3.6.1.4.1.164.3.3.1.3.21 | sysSBusTable | 1 | 5 | This table includes data and status about the internal DXC BUS. |
1.3.6.1.4.1.164.3.3.1.3.22 | sysSRdnCmdTable | 1 | 2 | This table includes commands used for IO Redundancy. |