This attribute indicates a unique port number.
For DXC:
The same numbering as for prtGenPrtIdx.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside.
* The external ports convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
For Optimux-T3:
Link-A: 51
Link-B: 61 .
Parsed from file Rad0485.MIB.txt
Company: None
Module: RAD-MIB
This attribute indicates a unique port number.
For DXC:
The same numbering as for prtGenPrtIdx.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside.
* The external ports convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
For Optimux-T3:
Link-A: 51
Link-B: 61 .
Parsed from file RAD-MIB.mib
Module: RAD-MIB
Vendor: Rad Data Communications Ltd.
Module: DACS-MIB
[Automatically extracted from oidview.com]
prtT3E3PrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. For DXC: The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The external ports convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For Optimux-T3: Link-A: 51 Link-B: 61 . " ::= { prtT3E3CnfgEntry 2}
prtT3E3PrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. For DXC: The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The external ports convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For Optimux-T3: Link-A: 51 Link-B: 61 . " ::= { prtT3E3CnfgEntry 2}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.3.3.3.8.1.1.1 | prtT3E3CnfgIdx | 0 | 0 | This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For DXC, wri… |
1.3.6.1.4.1.164.3.3.3.8.1.1.3 | prtT3E3Slt | 0 | 0 | This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this o… |
1.3.6.1.4.1.164.3.3.3.8.1.1.4 | prtT3E3LineLength | 0 | 0 | This object is the length of the ds3 line in feet. It provides information for line build out circuitry if it exists and can use … |
1.3.6.1.4.1.164.3.3.3.8.1.1.5 | prtT3E3InbandMng | 0 | 0 | A unique number to identify the Frame Type over the link. For Optimux-T3: only values (4), (7) are supported. |
1.3.6.1.4.1.164.3.3.3.8.1.1.6 | prtT3E3AisFrame | 0 | 0 | This object is applicable only for Optimux-T3. It allows user to select whether the AIS sent will be framed or unframed. |
1.3.6.1.4.1.164.3.3.3.8.1.1.7 | prtT3E3TxClockSource | 0 | 0 | Tx Clock Source. |
1.3.6.1.4.1.164.3.3.3.8.1.1.8 | prtT3E3RoutProt | 0 | 0 | Routing Protocol of the port. This object is applicable only for T3 ports. |