This attribute indicates a unique number to identify the slot where
the card is inserted in.
When the unit is stand-alone, this object is not applicable
and 255 will be used.
Parsed from file Rad0485.MIB.txt
Company: None
Module: RAD-MIB
This attribute indicates a unique number to identify the slot where
the card is inserted in.
When the unit is stand-alone, this object is not applicable
and 255 will be used.
Parsed from file RAD-MIB.mib
Module: RAD-MIB
Vendor: Rad Data Communications Ltd.
Module: DACS-MIB
[Automatically extracted from oidview.com]
prtT3E3Slt OBJECT-TYPE SYNTAX INTEGER { clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), standAlone (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used." ::= { prtT3E3CnfgEntry 3}
prtT3E3Slt OBJECT-TYPE SYNTAX INTEGER { clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), standAlone (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used." ::= { prtT3E3CnfgEntry 3}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.3.3.3.8.1.1.1 | prtT3E3CnfgIdx | 0 | 0 | This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For DXC, wri… |
1.3.6.1.4.1.164.3.3.3.8.1.1.2 | prtT3E3PrtIdx | 0 | 0 | This attribute indicates a unique port number. For DXC: The same numbering as for prtGenPrtIdx. The valid port number depends on … |
1.3.6.1.4.1.164.3.3.3.8.1.1.4 | prtT3E3LineLength | 0 | 0 | This object is the length of the ds3 line in feet. It provides information for line build out circuitry if it exists and can use … |
1.3.6.1.4.1.164.3.3.3.8.1.1.5 | prtT3E3InbandMng | 0 | 0 | A unique number to identify the Frame Type over the link. For Optimux-T3: only values (4), (7) are supported. |
1.3.6.1.4.1.164.3.3.3.8.1.1.6 | prtT3E3AisFrame | 0 | 0 | This object is applicable only for Optimux-T3. It allows user to select whether the AIS sent will be framed or unframed. |
1.3.6.1.4.1.164.3.3.3.8.1.1.7 | prtT3E3TxClockSource | 0 | 0 | Tx Clock Source. |
1.3.6.1.4.1.164.3.3.3.8.1.1.8 | prtT3E3RoutProt | 0 | 0 | Routing Protocol of the port. This object is applicable only for T3 ports. |