If LK2 is installed in the MMX-4230 then the Output
Packet is always contains ReedSolomon Code. If LK2
is not installed then the packet size is the same as
the input packet size.
If LK2 is installed in the MMM-4230 then if the input
signal contains ReedSolomon Code it is passed unchanged.
If LK2 is not installed then ReedSolomon Code is always
added internally.
Parsed from file IRT4230MMx-MIB.my.txt
Company: irtelectronics
Module: IRT4230MMx-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
irt4230ReedSolomon OBJECT-TYPE SYNTAX INTEGER { sameAsInput(1), passAlways(2), recalculate(3), passIfPresent(4) } ACCESS read-only STATUS mandatory DESCRIPTION "If LK2 is installed in the MMX-4230 then the Output Packet is always contains ReedSolomon Code. If LK2 is not installed then the packet size is the same as the input packet size. If LK2 is installed in the MMM-4230 then if the input signal contains ReedSolomon Code it is passed unchanged. If LK2 is not installed then ReedSolomon Code is always added internally." ::= { irt4230MMx 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.16557.3.2.6.0 | irt4230ReedSolomon | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.16557.3.2.1 | irt4230Alarms | 1 | 1 | The current state of the Urgent and Non Urgent alarms. inputLoss, ais and syncLoss are only available for a MMX-4230. |
1.3.6.1.4.1.16557.3.2.2 | irt4230ChannelTable | 1 | 7 | None |
1.3.6.1.4.1.16557.3.2.3 | irt4230ChannelAllocSwitch | 1 | 1 | The value to which the Channel Bandwidth Allocation Switch has been set in a MMM-4230. The MMX-4230 does not have a Bandwidth All… |
1.3.6.1.4.1.16557.3.2.4 | irt4230ChannelAlloc | 1 | 1 | The actual value being used by an MMM-4230 module for Channel Bandwidth Allocation. An MMX-4230 will always report 'remote(15)' |
1.3.6.1.4.1.16557.3.2.5 | irt4230Lk3State | 1 | 1 | If LK3 is installed then the channels may be individually inhibited at the receiver output. If LK3 is not installed then all outp… |
1.3.6.1.4.1.16557.3.2.7 | irt4230Framing | 1 | 1 | If LK4 is installed then the DS3 signal is framed. Otherwise the DS3 is treated as unframed. |
1.3.6.1.4.1.16557.3.2.8 | irt4230G703State | 1 | 1 | If LK5 is installed in a MMM-4230 then the G703 signal is Low (Shaped), otherwise it is High (DSX). If LK5 is installed in a MMX-… |
1.3.6.1.4.1.16557.3.2.9 | irt4230FpgaVersion | 1 | 1 | The software version of the main FPGA in the format 'x.y' where x is the major revision number and y is the minor revision. |
1.3.6.1.4.1.16557.3.2.10 | irt4230Reset | 1 | 1 | Writing a 2 to this object will cause the agent to reset. |
1.3.6.1.4.1.16557.3.2.11 | irt4230Trap | 1 | 1 | An indication whether traps are enabled from this module. |
1.3.6.1.4.1.16557.3.2.12 | irt4230RsErrors | 1 | 1 | The total of all ReedSolomomn errors detected at the MMX-4230 for all channels plus the data channel. This total may be set to ze… |