Reset the module to power-up default settings.
Parsed from file IRT4320DDA-MIB.my.txt
Company: irtelectronics
Module: IRT4320DDA-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
irt4320ddaReset OBJECT-TYPE SYNTAX INTEGER { normal(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset the module to power-up default settings." ::= { irt4320DDA 14 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.16557.3.54.14.0 | irt4320ddaReset | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.16557.3.54.1 | irt4320ddaAlarms | 1 | 1 | Status of the module's alarms. AIS detected: AIS detected in STM-1 data. Urgent alarm: Invalid input. |
1.3.6.1.4.1.16557.3.54.2 | irt4320ddaModuleStatus | 1 | 1 | Operational status in relation to (optional) partner module. 1. Main: This module controls the shared outputs. To capture shared … |
1.3.6.1.4.1.16557.3.54.3 | irt4320ddaInputInfo | 1 | 1 | Input status information. 1. Not present: Input not detected. 2. Not locked: Input present, but reclocker unlocked. 3. Locked: Rec… |
1.3.6.1.4.1.16557.3.54.4 | irt4320ddaInvertInput | 1 | 1 | Invert the input data before processing. |
1.3.6.1.4.1.16557.3.54.5 | irt4320ddaDataRate | 1 | 1 | Input data rate. SW3-1, SW3-2, SW3-3 on the PCB override this SNMP setting. |
1.3.6.1.4.1.16557.3.54.6 | irt4320ddaDataRateCtrl | 1 | 1 | Indication that SW3-1, SW3-2, SW3-3 on the PCB are overriding the SNMP setting for the reclocker data rate. |
1.3.6.1.4.1.16557.3.54.7 | irt4320ddaCableEQ | 1 | 1 | Amount of cable equalisation employed. Normal: Maximum available. Reduced: Lower gain for use in a noisy environment. SW3-4 on the… |
1.3.6.1.4.1.16557.3.54.8 | irt4320ddaOutputAIS | 1 | 1 | Output AIS in STM-1, upon loss of signal. SW3-5 on the PCB controls this setting. |
1.3.6.1.4.1.16557.3.54.9 | irt4320ddaChangeOnAIS | 1 | 1 | Attempt to changeover to the standby module upon detection of AIS in STM-1 input data. SW3-6 on the PCB controls this setting. |
1.3.6.1.4.1.16557.3.54.10 | irt4320ddaModuleStatusTrapEn | 1 | 1 | Send a trap upon change of module status, i.e. main <-> standby. |
1.3.6.1.4.1.16557.3.54.11 | irt4320ddaAlarmsTrapEn | 1 | 1 | Send a trap upon change of alarms status, i.e. invalid input or AIS. |
1.3.6.1.4.1.16557.3.54.12 | irt4320ddaFirmwareVer | 1 | 1 | Version of the FPGA firmware. |
1.3.6.1.4.1.16557.3.54.13 | irt4320ddaSoftwareVer | 1 | 1 | Version of the processor software. |