Current status of the primary stratum card.
Parsed from file ac120.my.V07.00.C00.mib.txt
Company: None
Module: ACMIB
Current status of the primary stratum card.
synchronized3(1) stratum is synchronized with accuracy
4.6 x 10e-6
synchronized4(2) stratum is synchronized with accuracy
3.2 x 10e-5
holdover(3) an operating condition of a clock that has
lost its controlling input and is using
stored data acquired while in normal
operation, to control its output
freerun(4) an operating condition of the clock whose
output signals are internally controlled
cardRemoved(5) stratum removed
Parsed from file ACMIB.mib
Module: ACMIB
Vendor: Lucent Technologies
Module: ACMIB
[Automatically extracted from oidview.com]
stratumMode OBJECT-TYPE SYNTAX INTEGER { synchronized3(1), synchronized4(2), holdover(3), freerun(4), cardRemoved(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of the primary stratum card." ::= { stratumConfig 7 }
stratumMode OBJECT-TYPE SYNTAX INTEGER { synchronized3(1), synchronized4(2), holdover(3), freerun(4), cardRemoved(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of the primary stratum card. synchronized3(1) stratum is synchronized with accuracy 4.6 x 10e-6 synchronized4(2) stratum is synchronized with accuracy 3.2 x 10e-5 holdover(3) an operating condition of a clock that has lost its controlling input and is using stored data acquired while in normal operation, to control its output freerun(4) an operating condition of the clock whose output signals are internally controlled cardRemoved(5) stratum removed " ::= { stratumConfig 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.17.7.0 | stratumMode | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.17.1 | stratumSyncSource | 1 | 1 | Clock source for the stratum card - lineTiming: must have slot and port specified in stratumPrimaryLineId. compositeClock: local c… |
1.3.6.1.4.1.1751.2.18.17.2 | stratumPrimaryLineId | 1 | 1 | Format SSPP (slot and port #'s) to be used when lineTiming is specified in stratumSyncSource. |
1.3.6.1.4.1.1751.2.18.17.3 | stratumSecondaryLineId | 1 | 1 | Format SSPP (slot and port #'s) to be used if the primary line has failed. Zeros imply that the stratum should switch to holdover… |
1.3.6.1.4.1.1751.2.18.17.4 | stratumLevel | 1 | 1 | Enable or disable the switching over to stratum 4 when stratum 3 is not possible. |
1.3.6.1.4.1.1751.2.18.17.5 | stratumLineCommand | 1 | 1 | Forces the stratum card to use one of the two specified lines as its clock source when the stratumSyncSource is lineTiming. |
1.3.6.1.4.1.1751.2.18.17.6 | stratumLineTimingStatus | 1 | 1 | Represents the source of the current clock. |
1.3.6.1.4.1.1751.2.18.17.8 | stratumBackupMode | 1 | 1 | Current status of the backup stratum card. |
1.3.6.1.4.1.1751.2.18.17.9 | stratumRefFailAction | 1 | 1 | Defines whether the stratum should switch to freerun or holdover on reference clock failure. |
1.3.6.1.4.1.1751.2.18.17.10 | stratumPortStatus | 1 | 1 | Current status of the primary stratum card. portFOS indicates port frequency offset. |
1.3.6.1.4.1.1751.2.18.17.11 | stratumBkupPortStatus | 1 | 1 | Current status of the backup stratum card. portFOS indicates port frequency offset. |
1.3.6.1.4.1.1751.2.18.17.12 | activeStratum | 1 | 1 | Current status of the backup stratum card. |