An entry in the ATM active SVC table. There is one
entry in the table corresponding to each active row
in the atm SPVC VCC Table for which the
atmSpvcVccConnType takes the value 'activeSvc'.
Parsed from file ac120.my.V07.00.C00.mib.txt
Company: None
Module: ACMIB
An entry in the ATM active SVC table. There is one
entry in the table corresponding to each active row
in the atm SPVC VCC Table for which the
atmSpvcVccConnType takes the value 'activeSvc'.
Parsed from file ACMIB.mib
Module: ACMIB
Vendor: Lucent Technologies
Module: ACMIB
[Automatically extracted from oidview.com]
atmSpvcVccActiveSvcEntry OBJECT-TYPE SYNTAX AtmSpvcVccActiveSvcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM active SVC table. There is one entry in the table corresponding to each active row in the atm SPVC VCC Table for which the atmSpvcVccConnType takes the value 'activeSvc'." INDEX { atmSpvcVccIfA, atmSpvcVccVpiA, atmSpvcVccVciA } ::= { atmSpvcVccActiveSvcTable 1 }
atmSpvcVccActiveSvcEntry OBJECT-TYPE SYNTAX AtmSpvcVccActiveSvcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM active SVC table. There is one entry in the table corresponding to each active row in the atm SPVC VCC Table for which the atmSpvcVccConnType takes the value 'activeSvc'." INDEX { atmSpvcVccIfA, atmSpvcVccVpiA, atmSpvcVccVciA } ::= { atmSpvcVccActiveSvcTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.6.18.1.1 | atmSpvcVccRemoteAtmPortAddr | 0 | 0 | Remote ATM port NSAP address, not meaningful if passive type of connection. |
1.3.6.1.4.1.1751.2.18.6.18.1.2 | atmSpvcVccRemoteSelectType | 0 | 0 | Indicates whether the remote VPI/VCI values are to be used at the destination. If 'any' is used, the destination switch will cho… |
1.3.6.1.4.1.1751.2.18.6.18.1.3 | atmSpvcVccRemoteVpi | 0 | 0 | VPI value to be used at the destination of an ATM SPVC VCC connection. Valid range is a number between 0 and 4095. If atmSpvcVc… |
1.3.6.1.4.1.1751.2.18.6.18.1.4 | atmSpvcVccRemoteVci | 0 | 0 | VCI value to be used at the destination of an ATM SPVC VCC connection. Valid range is a number between 0 and 65535. If atmSpvcV… |
1.3.6.1.4.1.1751.2.18.6.18.1.5 | atmSpvcVccRetryInterval | 0 | 0 | The time to wait before attempting to establish the SVC after a previous failed call attempt. A value of 0 indicates retry will … |
1.3.6.1.4.1.1751.2.18.6.18.1.6 | atmSpvcVccRetryLimit | 0 | 0 | A maximum limit on how many retries should be attempted. A value of 0 indicates no limit. |
1.3.6.1.4.1.1751.2.18.6.18.1.7 | atmSpvcVccRestart | 0 | 0 | The active SVC is released, if necessary, and a new setup procedure is begun if 'restart', otherwise, noop. |
1.3.6.1.4.1.1751.2.18.6.18.1.8 | atmSpvcVccRetryFailure | 0 | 0 | Indicates how many attempts to establish the connection have failed. It it reset whenever a connection is successfully establish… |
1.3.6.1.4.1.1751.2.18.6.18.1.9 | atmSpvcVccReleaseCause | 0 | 0 | CAUSE field value of the last RELEASE message received for this SVC. |
1.3.6.1.4.1.1751.2.18.6.18.1.10 | atmSpvcVccReleaseDiag | 0 | 0 | DIAGNOSTICS field value of the last RELEASE message received for this SVC. |