restart, the active SVC is released if necessary
and a new setup procedure is begun; or noop
Parsed from file ac120.my.V07.00.C00.mib.txt
Company: None
Module: ACMIB
restart, the active SVC is released if necessary
and a new setup procedure is begun; or noop
Parsed from file ACMIB.mib
Module: ACMIB
Vendor: Lucent Technologies
Module: ACMIB
[Automatically extracted from oidview.com]
vbrAtmSpvcRestart OBJECT-TYPE SYNTAX INTEGER { restart(1), noop(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "restart, the active SVC is released if necessary and a new setup procedure is begun; or noop" ::= { vbrAtmSpvcEntry 19 }
vbrAtmSpvcRestart OBJECT-TYPE SYNTAX INTEGER { restart(1), noop(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "restart, the active SVC is released if necessary and a new setup procedure is begun; or noop" ::= { vbrAtmSpvcEntry 19 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.6.35.1.1 | vbrAtmSpvcRemoteVbrPortAddr | 0 | 0 | remote VBR port nsap address implemening IWF, not meaningful if passive type of connection |
1.3.6.1.4.1.1751.2.18.6.35.1.2 | vbrAtmSpvcIfB | 0 | 0 | Interface index for side B, the atm side, of a variable bit rate-atm SPVC VCC connection. Number value is interpreted as an inte… |
1.3.6.1.4.1.1751.2.18.6.35.1.3 | vbrAtmSpvcVpiB | 0 | 0 | VPI value for side B, the atm side, of a variable bit rate-atm SPVC VCC connection. Valid range is a number between 0 and 4095. |
1.3.6.1.4.1.1751.2.18.6.35.1.4 | vbrAtmSpvcVciB | 0 | 0 | VCI value for side B, the atm side, of a variable bit rate-atm SPVC VCC connection. Valid range is a number between 0 and 65535. |
1.3.6.1.4.1.1751.2.18.6.35.1.5 | vbrAtmSpvcServiceType | 0 | 0 | service type |
1.3.6.1.4.1.1751.2.18.6.35.1.6 | vbrAtmSpvcPeakCellRateA2B | 0 | 0 | peak cell rate - side A, in cell per second |
1.3.6.1.4.1.1751.2.18.6.35.1.7 | vbrAtmSpvcSusCellRateA2B | 0 | 0 | sustained rate - side A, in cell per second |
1.3.6.1.4.1.1751.2.18.6.35.1.8 | vbrAtmSpvcMaxBurstSizeA2B | 0 | 0 | maximum burst size - side A, in cells |
1.3.6.1.4.1.1751.2.18.6.35.1.9 | vbrAtmSpvcPeakCellRateB2A | 0 | 0 | peak rate - side B, ATM trunk, in cell per second. |
1.3.6.1.4.1.1751.2.18.6.35.1.10 | vbrAtmSpvcSusCellRateB2A | 0 | 0 | sustained rate - side B, ATM trunk, in cell per second. |
1.3.6.1.4.1.1751.2.18.6.35.1.11 | vbrAtmSpvcMaxBurstSizeB2A | 0 | 0 | maximum burst size - side B, ATM trunk, in cells. |
1.3.6.1.4.1.1751.2.18.6.35.1.12 | vbrAtmSpvcFlow | 0 | 0 | type of flow |
1.3.6.1.4.1.1751.2.18.6.35.1.13 | vbrAtmSpvcConnType | 0 | 0 | The type of connection: activeSvc - attempt calls, whenever not established; passiveSvc - accepts calls |
1.3.6.1.4.1.1751.2.18.6.35.1.14 | vbrAtmSpvcOperStatus | 0 | 0 | other - none of the types specified below; establishmentInProgress - connection is not operational, but call attempts are ongoing… |
1.3.6.1.4.1.1751.2.18.6.35.1.15 | vbrAtmSpvcRowStatus | 0 | 0 | Used to create and delete a soft PVCC. When this object is set to 'active' an attempt is made to set up the soft PVCC. When thi… |
1.3.6.1.4.1.1751.2.18.6.35.1.16 | vbrAtmSpvcViB | 0 | 0 | VI to associate the Egress part of the B2A connection . |
1.3.6.1.4.1.1751.2.18.6.35.1.17 | vbrAtmSpvcRetryInterval | 0 | 0 | the time to wait before attempting to establish the SVC after previous failed call attempt. 0 indicates retries will be attempted… |
1.3.6.1.4.1.1751.2.18.6.35.1.18 | vbrAtmSpvcRetryLimit | 0 | 0 | a maximum limit on how many retries. 0 indicates no limit. |
1.3.6.1.4.1.1751.2.18.6.35.1.20 | vbrAtmSpvcRetryFailure | 0 | 0 | indicates how many attempts to establish the connection have failed. It is reset whenever a connection is successfully establish… |
1.3.6.1.4.1.1751.2.18.6.35.1.21 | vbrAtmSpvcReleaseCause | 0 | 0 | CAUSE field value of the last RELEASE message received for this SVC |
1.3.6.1.4.1.1751.2.18.6.35.1.22 | vbrAtmSpvcReleaseDiag | 0 | 0 | DIAGNOSTICS field value of the last RELEASE message received for this SVC |
1.3.6.1.4.1.1751.2.18.6.35.1.23 | vbrAtmSpvcRelease | 0 | 0 | Release the connnection established on the endpoint and if the endpoint is Active, do not retry. |
1.3.6.1.4.1.1751.2.18.6.35.1.24 | vbrAtmSpvcStatsCellsEncodedHiA | 0 | 0 | Cells encoded on side A- (High order portion) |
1.3.6.1.4.1.1751.2.18.6.35.1.25 | vbrAtmSpvcStatsCellsEncodedLoA | 0 | 0 | ells encoded on side A - (Low order portion) |
1.3.6.1.4.1.1751.2.18.6.35.1.26 | vbrAtmSpvcStatsCellsDecodedHiA | 0 | 0 | Cells decoded on side A - (High order portion) |
1.3.6.1.4.1.1751.2.18.6.35.1.27 | vbrAtmSpvcStatsCellsDecodedLoA | 0 | 0 | Cells decoded on side A - (Low order portion) |
1.3.6.1.4.1.1751.2.18.6.35.1.28 | vbrAtmSpvcStatsInCellCountHiB | 0 | 0 | Valid Cells received on B - (High order portion) |
1.3.6.1.4.1.1751.2.18.6.35.1.29 | vbrAtmSpvcStatsInCellCountLoB | 0 | 0 | Valid Cells received on B - (Low order portion) |
1.3.6.1.4.1.1751.2.18.6.35.1.30 | vbrAtmSpvcStatsOutCellCountHiB | 0 | 0 | Valid cells transmitted on B -(High order portion) |
1.3.6.1.4.1.1751.2.18.6.35.1.31 | vbrAtmSpvcStatsOutCellCountLoB | 0 | 0 | Valid cells transmitted on B - (Low order portion) |
1.3.6.1.4.1.1751.2.18.6.35.1.32 | vbrAtmSpvcStatsTimer | 0 | 0 | Number of seconds stats have been collecting |
1.3.6.1.4.1.1751.2.18.6.35.1.33 | vbrAtmSpvcStatsOdometerCellsEncodedHiA | 0 | 0 | Cells encoded on side A- (High order portion) |
1.3.6.1.4.1.1751.2.18.6.35.1.34 | vbrAtmSpvcStatsOdometerCellsEncodedLoA | 0 | 0 | Cells encoded on side A- (Low order portion) |
1.3.6.1.4.1.1751.2.18.6.35.1.35 | vbrAtmSpvcStatsOdometerCellsDecodedHiA | 0 | 0 | Cells decoded on side A- (High order portion) |
1.3.6.1.4.1.1751.2.18.6.35.1.36 | vbrAtmSpvcStatsOdometerCellsDecodedLoA | 0 | 0 | Cells decoded on side A- (Low order portion) |
1.3.6.1.4.1.1751.2.18.6.35.1.37 | vbrAtmSpvcStatsInOdometerCellCountHiB | 0 | 0 | Valid Cells received on B - (High order portion) |
1.3.6.1.4.1.1751.2.18.6.35.1.38 | vbrAtmSpvcStatsInOdometerCellCountLoB | 0 | 0 | Valid Cells received on B - (Low order portion) |
1.3.6.1.4.1.1751.2.18.6.35.1.39 | vbrAtmSpvcStatsOutOdometerCellCountHiB | 0 | 0 | Valid Cells transmitted on B -(High order portion) |
1.3.6.1.4.1.1751.2.18.6.35.1.40 | vbrAtmSpvcStatsOutOdometerCellCountLoB | 0 | 0 | Valid Cells transmitted on B -(Low order portion) |
1.3.6.1.4.1.1751.2.18.6.35.1.41 | vbrAtmSpvcStatsOdometerTimer | 0 | 0 | Number of seconds since odometer was reset. |
1.3.6.1.4.1.1751.2.18.6.35.1.42 | vbrAtmSpvcStatsOdometerReset | 0 | 0 | Odometer reset button. |
1.3.6.1.4.1.1751.2.18.6.35.1.43 | vbrAtmSpvcStatsCellsDroppedB | 0 | 0 | Cells Dropped on the Incoming side of B |
1.3.6.1.4.1.1751.2.18.6.35.1.44 | vbrAtmSpvcStatsCellsTaggedB | 0 | 0 | Cells Tagged on the Incoming side of B |
1.3.6.1.4.1.1751.2.18.6.35.1.45 | vbrAtmSpvcVUNIB | 0 | 0 | VUNI to associate the Egress part of the B2A connection . |
1.3.6.1.4.1.1751.2.18.6.35.1.46 | vbrAtmSpvcTrafficShapingA2B | 0 | 0 | Traffic Shaping Support in the A2B direction. |
1.3.6.1.4.1.1751.2.18.6.35.1.47 | vbrAtmSpvcPriority | 0 | 0 | Priority of SPVC - priority-1 being highest priority . |