Reference record for OID 1.3.6.1.4.1.1751.2.18.6.7.1.27



parent
1.3.6.1.4.1.1751.2.18.6.7.1 (frAtmPvcVccEntry)
node code
27
node name
frAtmPvcVccConnectionStatus
dot oid
1.3.6.1.4.1.1751.2.18.6.7.1.27
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lucent(1751) mibs(2) acMIB(18) connectionConfig(6) frAtmPvcVccTable(7) frAtmPvcVccEntry(1) frAtmPvcVccConnectionStatus(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lucent(1751) lucent-MIB(2) acMIB(18) connectionConfig(6) frAtmPvcVccTable(7) frAtmPvcVccEntry(1) frAtmPvcVccConnectionStatus(27)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) lucent(1751) mibs(2) acMIB(18) connectionConfig(6) frAtmPvcVccTable(7) frAtmPvcVccEntry(1) frAtmPvcVccConnectionStatus(27)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) lucent(1751) lucent-MIB(2) acMIB(18) connectionConfig(6) frAtmPvcVccTable(7) frAtmPvcVccEntry(1) frAtmPvcVccConnectionStatus(27)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) lucent(1751) mibs(2) acMIB(18) connectionConfig(6) frAtmPvcVccTable(7) frAtmPvcVccEntry(1) frAtmPvcVccConnectionStatus(27)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) lucent(1751) lucent-MIB(2) acMIB(18) connectionConfig(6) frAtmPvcVccTable(7) frAtmPvcVccEntry(1) frAtmPvcVccConnectionStatus(27)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lucent(1751) mibs(2) acMIB(18) connectionConfig(6) frAtmPvcVccTable(7) frAtmPvcVccEntry(1) frAtmPvcVccConnectionStatus(27)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lucent(1751) lucent-MIB(2) acMIB(18) connectionConfig(6) frAtmPvcVccTable(7) frAtmPvcVccEntry(1) frAtmPvcVccConnectionStatus(27)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/lucent/mibs/acMIB/connectionConfig/frAtmPvcVccTable/frAtmPvcVccEntry/frAtmPvcVccConnectionStatus
  • /iso/identified-organization/dod/internet/private/enterprise/lucent/lucent-MIB/acMIB/connectionConfig/frAtmPvcVccTable/frAtmPvcVccEntry/frAtmPvcVccConnectionStatus
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/lucent/mibs/acMIB/connectionConfig/frAtmPvcVccTable/frAtmPvcVccEntry/frAtmPvcVccConnectionStatus
  • /iso/org/dod/internet/private/enterprise/lucent/lucent-MIB/acMIB/connectionConfig/frAtmPvcVccTable/frAtmPvcVccEntry/frAtmPvcVccConnectionStatus
  • /iso/org/dod/internet/private/enterprises/lucent/mibs/acMIB/connectionConfig/frAtmPvcVccTable/frAtmPvcVccEntry/frAtmPvcVccConnectionStatus
  • /iso/org/dod/internet/private/enterprises/lucent/lucent-MIB/acMIB/connectionConfig/frAtmPvcVccTable/frAtmPvcVccEntry/frAtmPvcVccConnectionStatus
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/lucent/mibs/acMIB/connectionConfig/frAtmPvcVccTable/frAtmPvcVccEntry/frAtmPvcVccConnectionStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprises/lucent/lucent-MIB/acMIB/connectionConfig/frAtmPvcVccTable/frAtmPvcVccEntry/frAtmPvcVccConnectionStatus
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/1751/2/18/6/7/1/27

    Description by mibdepot

    Indicates the current connections status.
    Active: All interfaces through which the
    connection is going are in service.
    Inactive: One of the end interfaces of the
    connection is not in service.

    The rest of the states apply to connections going
    through resource interfaces like DSP2 and FEC. These
    interfaces are dynamically allocated.

    InactiveA2B-B2A: Both the A2B and B2A resource
    interfaces are not in service.
    InactiveA2B: The A2B resource interface is not in
    service.
    InactiveB2A: The B2A resource interface is not in
    service.

    If an end interface and the resource interfaces
    are out of service, the status will be inactive
    because the end interfaces take priority.

    Parsed from file ac120.my.V07.00.C00.mib.txt
    Company: None
    Module: ACMIB

    Description by circitor

    Indicates the current connections status.
    Active: All interfaces through which the
    connection is going are in service.
    Inactive: One of the end interfaces of the
    connection is not in service.

    The rest of the states apply to connections going
    through resource interfaces like DSP2 and FEC. These
    interfaces are dynamically allocated.

    InactiveA2B-B2A: Both the A2B and B2A resource
    interfaces are not in service.
    InactiveA2B: The A2B resource interface is not in
    service.
    InactiveB2A: The B2A resource interface is not in
    service.

    If an end interface and the resource interfaces
    are out of service, the status will be inactive
    because the end interfaces take priority.

    Parsed from file ACMIB.mib
    Module: ACMIB

    Information by oid_info

    Vendor: Lucent Technologies
    Module: ACMIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    frAtmPvcVccConnectionStatus OBJECT-TYPE SYNTAX INTEGER { active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority." DEFVAL { inactive } ::= { frAtmPvcVccEntry 27 }

    Information by circitor

    frAtmPvcVccConnectionStatus OBJECT-TYPE SYNTAX INTEGER { active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority." DEFVAL { inactive } ::= { frAtmPvcVccEntry 27 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.1751)

    Richard Bantel

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.1751)

    Håkon Helmers

    Brothers (37)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.1751.2.18.6.7.1.1 frAtmPvcVccIfA 0 0 Interface index for side A, the frame relay side,
    of a frame relay-atm PVC VCC connection. Number
    value is interpreted as an int…
    1.3.6.1.4.1.1751.2.18.6.7.1.2 frAtmPvcVccDlciA 0 0 DLCI value for side A, the frame relay side,
    of a frame relay-atm PVC VCC connection. Valid
    range is a number between 0 and 1023.
    1.3.6.1.4.1.1751.2.18.6.7.1.3 frAtmPvcVccIfB 0 0 Interface index for side B, the atm side, of a
    frame relay-atm PVC VCC connection. Number value
    is interpreted as an interface o…
    1.3.6.1.4.1.1751.2.18.6.7.1.4 frAtmPvcVccVpiB 0 0 VPI value for side B, the atm side, of a frame
    relay-atm PVC VCC connection. Valid range is a
    number between 0 and 4095.
    1.3.6.1.4.1.1751.2.18.6.7.1.5 frAtmPvcVccVciB 0 0 VCI value for side B, the atm side, of a frame
    relay-atm PVC VCC connection. Valid range is a
    number between 0 and 65535.
    1.3.6.1.4.1.1751.2.18.6.7.1.6 frAtmPvcVccMaxFrameSizeIn 0 0 The value of this object is the size in octets of
    the largest frame relay information field for this
    PVC in the ingress direction…
    1.3.6.1.4.1.1751.2.18.6.7.1.7 frAtmPvcVccBcIn 0 0 The value of this object is equal to the
    committed burst size (Bc) parameter (measured in
    bits) for this PVC in the ingress
    direct…
    1.3.6.1.4.1.1751.2.18.6.7.1.8 frAtmPvcVccBeIn 0 0 The value of this object is equal to the excess
    burst size (Be) parameter (measured in bits) for
    this PVC in the ingress directio…
    1.3.6.1.4.1.1751.2.18.6.7.1.9 frAtmPvcVccCirIn 0 0 The value of this object is equal to the
    committed information rate (CIR) parameter
    (measured in bits per second) for this PVC
    in …
    1.3.6.1.4.1.1751.2.18.6.7.1.10 frAtmPvcVccMaxFrameSizeOut 0 0 The value of this object is the size in octets of
    the largest frame relay information field for this
    PVC in the egress direction …
    1.3.6.1.4.1.1751.2.18.6.7.1.11 frAtmPvcVccBcOut 0 0 The value of this object is equal to the
    committed burst size (Bc) parameter (measured in
    bits) for this PVC in the egress
    directi…
    1.3.6.1.4.1.1751.2.18.6.7.1.12 frAtmPvcVccBeOut 0 0 The value of this object is equal to the excess
    burst size (Be) parameter (measured in bits) for
    this PVC in the egress direction…
    1.3.6.1.4.1.1751.2.18.6.7.1.13 frAtmPvcVccCirOut 0 0 The value of this object is equal to the
    committed information rate (CIR) parameter
    (measured in bits per second) for this PVC
    in …
    1.3.6.1.4.1.1751.2.18.6.7.1.14 frAtmPvcVccServiceType 0 0 service type, Frame relay traffic is carried
    by VBR type of service only.
    1.3.6.1.4.1.1751.2.18.6.7.1.15 frAtmPvcVccFlow 0 0 Flow Type
    1.3.6.1.4.1.1751.2.18.6.7.1.16 frAtmPvcVccRowStatus 0 0 row status
    1.3.6.1.4.1.1751.2.18.6.7.1.17 frAtmPvcVccTimeLenIn 0 0 The time interval over which CIR and the burst
    sizes (Bc and Be) are measured in the A2B
    direction. The unit is milliseconds.
    1.3.6.1.4.1.1751.2.18.6.7.1.18 frAtmPvcVccInterWorkingFuncIn 0 0 InterWorking function.
    1.3.6.1.4.1.1751.2.18.6.7.1.19 frAtmPvcVccTimeLenOut 0 0 The time interval over which CIR and the burst
    sizes (Bc and Be) are measured in the A2B
    direction. The unit is milliseconds.
    1.3.6.1.4.1.1751.2.18.6.7.1.20 frAtmPvcVccInterWorkingFuncOut 0 0 InterWorking function.
    1.3.6.1.4.1.1751.2.18.6.7.1.21 frAtmPvcVccPeakCellRateA2B 0 0 Peak cell rate - side A, in cells per second,
    this will reflect the frame relay parameters in
    atm terms.
    1.3.6.1.4.1.1751.2.18.6.7.1.22 frAtmPvcVccSusCellRateA2B 0 0 Sustained cell rate - side A, in cells per second,
    this will reflect the frame relay parameters in
    atm terms.
    1.3.6.1.4.1.1751.2.18.6.7.1.23 frAtmPvcVccMaxBurstSizeA2B 0 0 Maximum burst size - side A, in cells,
    this will reflect the frame relay parameters in
    atm terms.
    1.3.6.1.4.1.1751.2.18.6.7.1.24 frAtmPvcVccPeakCellRateB2A 0 0 Peak cell rate - side B, in cells per second,
    this will reflect the frame relay parameters in
    atm terms.
    1.3.6.1.4.1.1751.2.18.6.7.1.25 frAtmPvcVccSusCellRateB2A 0 0 Sustained cell rate - side B, in cells per second,
    this will reflect the frame relay parameters in
    atm terms.
    1.3.6.1.4.1.1751.2.18.6.7.1.26 frAtmPvcVccMaxBurstSizeB2A 0 0 Maximum burst size - side B, in cells,
    this will reflect the frame relay parameters in
    atm terms.
    1.3.6.1.4.1.1751.2.18.6.7.1.28 frAtmPvcVccDualHomed 0 0 Does this PVC need a backup Dual homing PVC.
    1.3.6.1.4.1.1751.2.18.6.7.1.29 frAtmPvcVccOamStatus 0 0 Indicates the OAM monitoring status of side A.
    The 2 possible states are:
    Unsupp: No monitoring enabled.
    End-Pt: A side is only …
    1.3.6.1.4.1.1751.2.18.6.7.1.30 frAtmPvcVccViB 0 0 VI to associate the Egress part of the
    A2B connection .
    1.3.6.1.4.1.1751.2.18.6.7.1.31 frAtmPvcVccCnfrmTypeB2A 0 0 The following is the description of this field
    This will be used in conjunction with the
    service type field to get the correct
    tra…
    1.3.6.1.4.1.1751.2.18.6.7.1.32 frAtmPvcVccVUNIB 0 0 VUNI to associate the Egress part of the
    A2B connection .
    1.3.6.1.4.1.1751.2.18.6.7.1.33 frAtmPvcVccOAMConnEndPtStatus 0 0 Connection endpoint status. Valid only
    at connection endpoint.
    1.3.6.1.4.1.1751.2.18.6.7.1.34 frAtmPvcVccOAMSegEndPtStatus 0 0 Segment endpoint status. Valid only at
    segment/connection endpoint.
    1.3.6.1.4.1.1751.2.18.6.7.1.35 frAtmPvcVccMfsB2A 0 0 Maximum Frame Size for GFR traffic
    1.3.6.1.4.1.1751.2.18.6.7.1.36 frAtmPvcVccConnFailureCauseA 0 0 connestion status reason code
    1.3.6.1.4.1.1751.2.18.6.7.1.37 frAtmPvcVccConnFailureCauseB 0 0 connection status reason code
    1.3.6.1.4.1.1751.2.18.6.7.1.38 frAtmPvcVccTrafficShapingA2B 0 0 Traffic Shaping Support in the A2B direction.