Segment endpoint status. Valid only at
segment/connection endpoint.
Parsed from file ac120.my.V07.00.C00.mib.txt
Company: None
Module: ACMIB
Segment endpoint status. Valid only at
segment/connection endpoint.
Parsed from file ACMIB.mib
Module: ACMIB
Vendor: Lucent Technologies
Module: ACMIB
[Automatically extracted from oidview.com]
frAtmPvcVccOAMSegEndPtStatus OBJECT-TYPE SYNTAX INTEGER { seg-active(1), seg-ais-state(2), seg-rdi-state(3), seg-ais-rdi-state(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Segment endpoint status. Valid only at segment/connection endpoint." ::= { frAtmPvcVccEntry 34 }
frAtmPvcVccOAMSegEndPtStatus OBJECT-TYPE SYNTAX INTEGER { seg-active(1), seg-ais-state(2), seg-rdi-state(3), seg-ais-rdi-state(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Segment endpoint status. Valid only at segment/connection endpoint." ::= { frAtmPvcVccEntry 34 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.6.7.1.1 | frAtmPvcVccIfA | 0 | 0 | Interface index for side A, the frame relay side, of a frame relay-atm PVC VCC connection. Number value is interpreted as an int… |
1.3.6.1.4.1.1751.2.18.6.7.1.2 | frAtmPvcVccDlciA | 0 | 0 | DLCI value for side A, the frame relay side, of a frame relay-atm PVC VCC connection. Valid range is a number between 0 and 1023. |
1.3.6.1.4.1.1751.2.18.6.7.1.3 | frAtmPvcVccIfB | 0 | 0 | Interface index for side B, the atm side, of a frame relay-atm PVC VCC connection. Number value is interpreted as an interface o… |
1.3.6.1.4.1.1751.2.18.6.7.1.4 | frAtmPvcVccVpiB | 0 | 0 | VPI value for side B, the atm side, of a frame relay-atm PVC VCC connection. Valid range is a number between 0 and 4095. |
1.3.6.1.4.1.1751.2.18.6.7.1.5 | frAtmPvcVccVciB | 0 | 0 | VCI value for side B, the atm side, of a frame relay-atm PVC VCC connection. Valid range is a number between 0 and 65535. |
1.3.6.1.4.1.1751.2.18.6.7.1.6 | frAtmPvcVccMaxFrameSizeIn | 0 | 0 | The value of this object is the size in octets of the largest frame relay information field for this PVC in the ingress direction… |
1.3.6.1.4.1.1751.2.18.6.7.1.7 | frAtmPvcVccBcIn | 0 | 0 | The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this PVC in the ingress direct… |
1.3.6.1.4.1.1751.2.18.6.7.1.8 | frAtmPvcVccBeIn | 0 | 0 | The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this PVC in the ingress directio… |
1.3.6.1.4.1.1751.2.18.6.7.1.9 | frAtmPvcVccCirIn | 0 | 0 | The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this PVC in … |
1.3.6.1.4.1.1751.2.18.6.7.1.10 | frAtmPvcVccMaxFrameSizeOut | 0 | 0 | The value of this object is the size in octets of the largest frame relay information field for this PVC in the egress direction … |
1.3.6.1.4.1.1751.2.18.6.7.1.11 | frAtmPvcVccBcOut | 0 | 0 | The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this PVC in the egress directi… |
1.3.6.1.4.1.1751.2.18.6.7.1.12 | frAtmPvcVccBeOut | 0 | 0 | The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this PVC in the egress direction… |
1.3.6.1.4.1.1751.2.18.6.7.1.13 | frAtmPvcVccCirOut | 0 | 0 | The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this PVC in … |
1.3.6.1.4.1.1751.2.18.6.7.1.14 | frAtmPvcVccServiceType | 0 | 0 | service type, Frame relay traffic is carried by VBR type of service only. |
1.3.6.1.4.1.1751.2.18.6.7.1.15 | frAtmPvcVccFlow | 0 | 0 | Flow Type |
1.3.6.1.4.1.1751.2.18.6.7.1.16 | frAtmPvcVccRowStatus | 0 | 0 | row status |
1.3.6.1.4.1.1751.2.18.6.7.1.17 | frAtmPvcVccTimeLenIn | 0 | 0 | The time interval over which CIR and the burst sizes (Bc and Be) are measured in the A2B direction. The unit is milliseconds. |
1.3.6.1.4.1.1751.2.18.6.7.1.18 | frAtmPvcVccInterWorkingFuncIn | 0 | 0 | InterWorking function. |
1.3.6.1.4.1.1751.2.18.6.7.1.19 | frAtmPvcVccTimeLenOut | 0 | 0 | The time interval over which CIR and the burst sizes (Bc and Be) are measured in the A2B direction. The unit is milliseconds. |
1.3.6.1.4.1.1751.2.18.6.7.1.20 | frAtmPvcVccInterWorkingFuncOut | 0 | 0 | InterWorking function. |
1.3.6.1.4.1.1751.2.18.6.7.1.21 | frAtmPvcVccPeakCellRateA2B | 0 | 0 | Peak cell rate - side A, in cells per second, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.7.1.22 | frAtmPvcVccSusCellRateA2B | 0 | 0 | Sustained cell rate - side A, in cells per second, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.7.1.23 | frAtmPvcVccMaxBurstSizeA2B | 0 | 0 | Maximum burst size - side A, in cells, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.7.1.24 | frAtmPvcVccPeakCellRateB2A | 0 | 0 | Peak cell rate - side B, in cells per second, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.7.1.25 | frAtmPvcVccSusCellRateB2A | 0 | 0 | Sustained cell rate - side B, in cells per second, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.7.1.26 | frAtmPvcVccMaxBurstSizeB2A | 0 | 0 | Maximum burst size - side B, in cells, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.7.1.27 | frAtmPvcVccConnectionStatus | 0 | 0 | Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: … |
1.3.6.1.4.1.1751.2.18.6.7.1.28 | frAtmPvcVccDualHomed | 0 | 0 | Does this PVC need a backup Dual homing PVC. |
1.3.6.1.4.1.1751.2.18.6.7.1.29 | frAtmPvcVccOamStatus | 0 | 0 | Indicates the OAM monitoring status of side A. The 2 possible states are: Unsupp: No monitoring enabled. End-Pt: A side is only … |
1.3.6.1.4.1.1751.2.18.6.7.1.30 | frAtmPvcVccViB | 0 | 0 | VI to associate the Egress part of the A2B connection . |
1.3.6.1.4.1.1751.2.18.6.7.1.31 | frAtmPvcVccCnfrmTypeB2A | 0 | 0 | The following is the description of this field This will be used in conjunction with the service type field to get the correct tra… |
1.3.6.1.4.1.1751.2.18.6.7.1.32 | frAtmPvcVccVUNIB | 0 | 0 | VUNI to associate the Egress part of the A2B connection . |
1.3.6.1.4.1.1751.2.18.6.7.1.33 | frAtmPvcVccOAMConnEndPtStatus | 0 | 0 | Connection endpoint status. Valid only at connection endpoint. |
1.3.6.1.4.1.1751.2.18.6.7.1.35 | frAtmPvcVccMfsB2A | 0 | 0 | Maximum Frame Size for GFR traffic |
1.3.6.1.4.1.1751.2.18.6.7.1.36 | frAtmPvcVccConnFailureCauseA | 0 | 0 | connestion status reason code |
1.3.6.1.4.1.1751.2.18.6.7.1.37 | frAtmPvcVccConnFailureCauseB | 0 | 0 | connection status reason code |
1.3.6.1.4.1.1751.2.18.6.7.1.38 | frAtmPvcVccTrafficShapingA2B | 0 | 0 | Traffic Shaping Support in the A2B direction. |