Indicates the current connections status.
Active: All interfaces through which the
connection is going are in service.
Inactive: One of the end interfaces of the
connection is not in service.
The rest of the states apply to connections going
through resource interfaces like DSP2 and FEC. These
interfaces are dynamically allocated.
InactiveA2B-B2A: Both the A2B and B2A resource
interfaces are not in service.
InactiveA2B: The A2B resource interface is not in
service.
InactiveB2A: The B2A resource interface is not in
service.
If an end interface and the resource interfaces
are out of service, the status will be inactive
because the end interfaces take priority.
Parsed from file ac120.my.V07.00.C00.mib.txt
Company: None
Module: ACMIB
Indicates the current connections status.
Active: All interfaces through which the
connection is going are in service.
Inactive: One of the end interfaces of the
connection is not in service.
The rest of the states apply to connections going
through resource interfaces like DSP2 and FEC. These
interfaces are dynamically allocated.
InactiveA2B-B2A: Both the A2B and B2A resource
interfaces are not in service.
InactiveA2B: The A2B resource interface is not in
service.
InactiveB2A: The B2A resource interface is not in
service.
If an end interface and the resource interfaces
are out of service, the status will be inactive
because the end interfaces take priority.
Parsed from file ACMIB.mib
Module: ACMIB
Vendor: Lucent Technologies
Module: ACMIB
[Automatically extracted from oidview.com]
frFrPvcConnectionStatus OBJECT-TYPE SYNTAX INTEGER { active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority." DEFVAL { inactive } ::= { frFrPvcEntry 26 }
frFrPvcConnectionStatus OBJECT-TYPE SYNTAX INTEGER { active(1), inactive(2), inactiveA2B-B2A(3), inactiveA2B(4), inactiveB2A(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service. The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated. InactiveA2B-B2A: Both the A2B and B2A resource interfaces are not in service. InactiveA2B: The A2B resource interface is not in service. InactiveB2A: The B2A resource interface is not in service. If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority." DEFVAL { inactive } ::= { frFrPvcEntry 26 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.6.8.1.1 | frFrPvcIfA | 0 | 0 | Interface index for side A of a frame relay-frame relay PVC connection. Number value is interpreted as an interface of the form,… |
1.3.6.1.4.1.1751.2.18.6.8.1.2 | frFrPvcDlciA | 0 | 0 | DLCI value for side A of a frame relay-frame relay PVC connection. Valid range is a number between 0 and 1023. |
1.3.6.1.4.1.1751.2.18.6.8.1.3 | frFrPvcIfB | 0 | 0 | Interface index for side B of a frame relay-frame relay PVC connection. Number value is interpreted as an interface of the form,… |
1.3.6.1.4.1.1751.2.18.6.8.1.4 | frFrPvcDlciB | 0 | 0 | DLCI value for side B of a frame relay-frame relay PVC connection. Valid range is a number between 0 and 1023. |
1.3.6.1.4.1.1751.2.18.6.8.1.5 | frFrPvcMaxFrameSizeA2B | 0 | 0 | The value of this object is the size in octets of the largest frame relay information field for this PVC in the A to B direction. |
1.3.6.1.4.1.1751.2.18.6.8.1.6 | frFrPvcBcA2B | 0 | 0 | The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this PVC in the A to B direct… |
1.3.6.1.4.1.1751.2.18.6.8.1.7 | frFrPvcBeA2B | 0 | 0 | The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this PVC in the A to B direction. |
1.3.6.1.4.1.1751.2.18.6.8.1.8 | frFrPvcCirA2B | 0 | 0 | The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this PVC in … |
1.3.6.1.4.1.1751.2.18.6.8.1.9 | frFrPvcMaxFrameSizeB2A | 0 | 0 | The value of this object is the size in octets of the largest frame relay information field for this PVC in the B to A direction. |
1.3.6.1.4.1.1751.2.18.6.8.1.10 | frFrPvcBcB2A | 0 | 0 | The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this PVC in the B to A direct… |
1.3.6.1.4.1.1751.2.18.6.8.1.11 | frFrPvcBeB2A | 0 | 0 | The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this PVC in the B to A direction. |
1.3.6.1.4.1.1751.2.18.6.8.1.12 | frFrPvcCirB2A | 0 | 0 | The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this PVC in … |
1.3.6.1.4.1.1751.2.18.6.8.1.13 | frFrPvcServiceType | 0 | 0 | service type, Frame relay traffic is carried by VBR type of service only. |
1.3.6.1.4.1.1751.2.18.6.8.1.14 | frFrPvcFlow | 0 | 0 | Flow Type |
1.3.6.1.4.1.1751.2.18.6.8.1.15 | frFrPvcRowStatus | 0 | 0 | row status |
1.3.6.1.4.1.1751.2.18.6.8.1.16 | frFrPvcTimeLenA2B | 0 | 0 | The time interval over which CIR and the burst sizes (Bc and Be) are measured in the A2B direction. The unit is milliseconds. |
1.3.6.1.4.1.1751.2.18.6.8.1.17 | frFrPvcInterWorkingFuncA2B | 0 | 0 | InterWorking function. |
1.3.6.1.4.1.1751.2.18.6.8.1.18 | frFrPvcTimeLenB2A | 0 | 0 | The time interval over which CIR and the burst sizes (Bc and Be) are measured in the A2B direction. The unit is milliseconds. |
1.3.6.1.4.1.1751.2.18.6.8.1.19 | frFrPvcInterWorkingFuncB2A | 0 | 0 | InterWorking function. |
1.3.6.1.4.1.1751.2.18.6.8.1.20 | frFrPvcPeakCellRateA2B | 0 | 0 | Peak cell rate - side A, in cells per second, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.8.1.21 | frFrPvcSusCellRateA2B | 0 | 0 | Sustained cell rate - side A, in cells per second, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.8.1.22 | frFrPvcMaxBurstSizeA2B | 0 | 0 | Maximum burst size - side A, in cells, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.8.1.23 | frFrPvcPeakCellRateB2A | 0 | 0 | Peak cell rate - side B, in cells per second, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.8.1.24 | frFrPvcSusCellRateB2A | 0 | 0 | Sustained cell rate - side B, in cells per second, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.8.1.25 | frFrPvcMaxBurstSizeB2A | 0 | 0 | Maximum burst size - side B, in cells, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.8.1.27 | frFrPvcConnFailureCauseA | 0 | 0 | connestion status reason code |
1.3.6.1.4.1.1751.2.18.6.8.1.28 | frFrPvcConnFailureCauseB | 0 | 0 | connection status reason code |