Interface index for side B of a frame relay-frame
relay PVC connection. Number value is interpreted
as an interface of the form, SSPPCCC, where SS is
the card slot, PP is the port number, and CCC is
the channel number.
Parsed from file ac120.my.V07.00.C00.mib.txt
Company: None
Module: ACMIB
Interface index for side B of a frame relay-frame
relay PVC connection. Number value is interpreted
as an interface of the form, SSPPCCC, where SS is
the card slot, PP is the port number, and CCC is
the channel number.
Parsed from file ACMIB.mib
Module: ACMIB
Vendor: Lucent Technologies
Module: ACMIB
[Automatically extracted from oidview.com]
frFrPvcIfB OBJECT-TYPE SYNTAX IntfIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interface index for side B of a frame relay-frame relay PVC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number." ::= { frFrPvcEntry 3 }
frFrPvcIfB OBJECT-TYPE SYNTAX IntfIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interface index for side B of a frame relay-frame relay PVC connection. Number value is interpreted as an interface of the form, SSPPCCC, where SS is the card slot, PP is the port number, and CCC is the channel number." ::= { frFrPvcEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.6.8.1.1 | frFrPvcIfA | 0 | 0 | Interface index for side A of a frame relay-frame relay PVC connection. Number value is interpreted as an interface of the form,… |
1.3.6.1.4.1.1751.2.18.6.8.1.2 | frFrPvcDlciA | 0 | 0 | DLCI value for side A of a frame relay-frame relay PVC connection. Valid range is a number between 0 and 1023. |
1.3.6.1.4.1.1751.2.18.6.8.1.4 | frFrPvcDlciB | 0 | 0 | DLCI value for side B of a frame relay-frame relay PVC connection. Valid range is a number between 0 and 1023. |
1.3.6.1.4.1.1751.2.18.6.8.1.5 | frFrPvcMaxFrameSizeA2B | 0 | 0 | The value of this object is the size in octets of the largest frame relay information field for this PVC in the A to B direction. |
1.3.6.1.4.1.1751.2.18.6.8.1.6 | frFrPvcBcA2B | 0 | 0 | The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this PVC in the A to B direct… |
1.3.6.1.4.1.1751.2.18.6.8.1.7 | frFrPvcBeA2B | 0 | 0 | The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this PVC in the A to B direction. |
1.3.6.1.4.1.1751.2.18.6.8.1.8 | frFrPvcCirA2B | 0 | 0 | The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this PVC in … |
1.3.6.1.4.1.1751.2.18.6.8.1.9 | frFrPvcMaxFrameSizeB2A | 0 | 0 | The value of this object is the size in octets of the largest frame relay information field for this PVC in the B to A direction. |
1.3.6.1.4.1.1751.2.18.6.8.1.10 | frFrPvcBcB2A | 0 | 0 | The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this PVC in the B to A direct… |
1.3.6.1.4.1.1751.2.18.6.8.1.11 | frFrPvcBeB2A | 0 | 0 | The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this PVC in the B to A direction. |
1.3.6.1.4.1.1751.2.18.6.8.1.12 | frFrPvcCirB2A | 0 | 0 | The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this PVC in … |
1.3.6.1.4.1.1751.2.18.6.8.1.13 | frFrPvcServiceType | 0 | 0 | service type, Frame relay traffic is carried by VBR type of service only. |
1.3.6.1.4.1.1751.2.18.6.8.1.14 | frFrPvcFlow | 0 | 0 | Flow Type |
1.3.6.1.4.1.1751.2.18.6.8.1.15 | frFrPvcRowStatus | 0 | 0 | row status |
1.3.6.1.4.1.1751.2.18.6.8.1.16 | frFrPvcTimeLenA2B | 0 | 0 | The time interval over which CIR and the burst sizes (Bc and Be) are measured in the A2B direction. The unit is milliseconds. |
1.3.6.1.4.1.1751.2.18.6.8.1.17 | frFrPvcInterWorkingFuncA2B | 0 | 0 | InterWorking function. |
1.3.6.1.4.1.1751.2.18.6.8.1.18 | frFrPvcTimeLenB2A | 0 | 0 | The time interval over which CIR and the burst sizes (Bc and Be) are measured in the A2B direction. The unit is milliseconds. |
1.3.6.1.4.1.1751.2.18.6.8.1.19 | frFrPvcInterWorkingFuncB2A | 0 | 0 | InterWorking function. |
1.3.6.1.4.1.1751.2.18.6.8.1.20 | frFrPvcPeakCellRateA2B | 0 | 0 | Peak cell rate - side A, in cells per second, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.8.1.21 | frFrPvcSusCellRateA2B | 0 | 0 | Sustained cell rate - side A, in cells per second, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.8.1.22 | frFrPvcMaxBurstSizeA2B | 0 | 0 | Maximum burst size - side A, in cells, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.8.1.23 | frFrPvcPeakCellRateB2A | 0 | 0 | Peak cell rate - side B, in cells per second, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.8.1.24 | frFrPvcSusCellRateB2A | 0 | 0 | Sustained cell rate - side B, in cells per second, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.8.1.25 | frFrPvcMaxBurstSizeB2A | 0 | 0 | Maximum burst size - side B, in cells, this will reflect the frame relay parameters in atm terms. |
1.3.6.1.4.1.1751.2.18.6.8.1.26 | frFrPvcConnectionStatus | 0 | 0 | Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: … |
1.3.6.1.4.1.1751.2.18.6.8.1.27 | frFrPvcConnFailureCauseA | 0 | 0 | connestion status reason code |
1.3.6.1.4.1.1751.2.18.6.8.1.28 | frFrPvcConnFailureCauseB | 0 | 0 | connection status reason code |