OID reference

linkSymmetry

1.3.6.1.4.1.17713.6.10.1

Description

Link Symmetry: in fixed symmetric mode the master spends an equal amount of time transmitting and receiving; in fixed asymmetric modes the master transmit and receive times have a fixed ratio; in adaptive mode the transmit and receive periods adjust with applied load.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.17713.6.10 (phyControl)
Node code
1
Node name
linkSymmetry
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.17713.6.10.1
URN notation
urn:oid:1.3.6.1.4.1.17713.6.10.1
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 17713 6 10 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) motorola(17713) ptp600(6) phyControl(10) linkSymmetry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cambium(17713) ptp600(6) phyControl(10) linkSymmetry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) terragraph(17713) ptp600(6) phyControl(10) linkSymmetry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) motorola(17713) ptp600(6) phyControl(10) linkSymmetry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cambium(17713) ptp600(6) phyControl(10) linkSymmetry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) terragraph(17713) ptp600(6) phyControl(10) linkSymmetry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) motorola(17713) ptp600(6) phyControl(10) linkSymmetry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) cambium(17713) ptp600(6) phyControl(10) linkSymmetry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) terragraph(17713) ptp600(6) phyControl(10) linkSymmetry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) motorola(17713) ptp600(6) phyControl(10) linkSymmetry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) cambium(17713) ptp600(6) phyControl(10) linkSymmetry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) terragraph(17713) ptp600(6) phyControl(10) linkSymmetry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) motorola(17713) ptp600(6) phyControl(10) linkSymmetry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cambium(17713) ptp600(6) phyControl(10) linkSymmetry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) terragraph(17713) ptp600(6) phyControl(10) linkSymmetry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) motorola(17713) ptp600(6) phyControl(10) linkSymmetry(1)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/17713/6/10/1
  • /ISO/Identified-Organization/6/1/4/1/17713/6/10/1
  • /ISO/3/6/1/4/1/17713/6/10/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/motorola/ptp600/phyControl/linkSymmetry
  • /iso/identified-organization/dod/internet/private/enterprise/cambium/ptp600/phyControl/linkSymmetry
  • /iso/identified-organization/dod/internet/private/enterprise/terragraph/ptp600/phyControl/linkSymmetry
  • /iso/identified-organization/dod/internet/private/enterprises/motorola/ptp600/phyControl/linkSymmetry
  • /iso/identified-organization/dod/internet/private/enterprises/cambium/ptp600/phyControl/linkSymmetry
  • /iso/identified-organization/dod/internet/private/enterprises/terragraph/ptp600/phyControl/linkSymmetry
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/motorola/ptp600/phyControl/linkSymmetry
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/cambium/ptp600/phyControl/linkSymmetry
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/terragraph/ptp600/phyControl/linkSymmetry
  • /iso/identified-organization/dod/internet/private/vendor-objects/motorola/ptp600/phyControl/linkSymmetry
  • /iso/identified-organization/dod/internet/private/vendor-objects/cambium/ptp600/phyControl/linkSymmetry
  • /iso/identified-organization/dod/internet/private/vendor-objects/terragraph/ptp600/phyControl/linkSymmetry
  • /iso/org/dod/internet/private/enterprise/motorola/ptp600/phyControl/linkSymmetry
  • /iso/org/dod/internet/private/enterprise/cambium/ptp600/phyControl/linkSymmetry
  • /iso/org/dod/internet/private/enterprise/terragraph/ptp600/phyControl/linkSymmetry
  • /iso/org/dod/internet/private/enterprises/motorola/ptp600/phyControl/linkSymmetry
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Enumerated values

ValueName
0symmetryAdaptive
1symmetry2to1
2symmetry1to1
3symmetry1to2

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.17713.6.10.1.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

linkSymmetry OBJECT-TYPE
      SYNTAX INTEGER {
                       symmetryAdaptive(0),
                       symmetry2to1(1),
                       symmetry1to1(2),
                       symmetry1to2(3)
                     }
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
             "Link Symmetry: in fixed symmetric mode the master spends 
             an equal amount of time transmitting and receiving; in 
             fixed asymmetric modes the master transmit and receive 
             times have a fixed ratio; in adaptive mode the transmit 
             and receive periods adjust with applied load."  
      ::= { phyControl 1 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Link Symmetry: in fixed symmetric mode the master spends an equal amount of time transmitting and receiving; in fixed asymmetric modes the master transmit and receive times have a fixed ratio; in adaptive mode the transmit and receive periods adjust with applied load.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

linkSymmetry · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: linkSymmetry

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "linkSymmetry",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "symmetryAdaptive",
    "(",
    "0",
    ")",
    ",",
    "symmetry2to1",
    "(",
    "1",
    ")",
    ",",
    "symmetry1to1",
    "(",
    "2",
    ")",
    ",",
    "symmetry1to2",
    "(",
    "3",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Link Symmetry: in fixed symmetric mode the master spends an equal amount of time transmitting and receiving; in fixed asymmetric modes the master transmit and receive times have a fixed ratio; in adaptive mode the transmit and receive periods adjust with applied load.\"",
    "::=",
    "{",
    "phyControl",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "symmetryAdaptive",
            0
          ],
          [
            "symmetry2to1",
            1
          ],
          [
            "symmetry1to1",
            2
          ],
          [
            "symmetry1to2",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Link Symmetry: in fixed symmetric mode the master spends an equal amount of time transmitting and receiving; in fixed asymmetric modes the master transmit and receive times have a fixed ratio; in adaptive mode the transmit and receive periods adjust with applied load."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.17713)

Carter Richard

Siblings (7)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.17713.6.10.2 linkModeOptimisation00
1.3.6.1.4.1.17713.6.10.3 userConfiguredMaxModulationMode00
1.3.6.1.4.1.17713.6.10.4 remoteMaximumTransmitPower00
1.3.6.1.4.1.17713.6.10.5 txColorCode00
1.3.6.1.4.1.17713.6.10.6 rxColorCode00
1.3.6.1.4.1.17713.6.10.8 automaticTxPowerControl00
1.3.6.1.4.1.17713.6.10.9 remoteRxTargetPower00