Status in source: current.
Names: remoteRxTargetPower
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"remoteRxTargetPower",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"-",
"600",
".",
".",
"-",
"400",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"This is the target receive level for the end of the link which is remote from the end being configured. When Automatic Power Control is enabled, the transmit power of the local end is automatically adjusted in order to maintain the receive signal level at the remote end within a range centered on this value\"",
"::=",
"{",
"phyControl",
"9",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
-600,
-400
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This is the target receive level for the end of the link which is remote from the end being configured. When Automatic Power Control is enabled, the transmit power of the local end is automatically adjusted in order to maintain the receive signal level at the remote end within a range centered on this value"
],
null,
null,
null,
null
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: CAMBIUM-PTP600-MIB
Vendor MIB copy from the LibreNMS archive.
Module: CAMBIUM-PTP600-MIB
See published definition above
Module imports
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'IpAddress', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType']}
· Download CAMBIUM-PTP600-MIB
Related source files and packages:
Same file in Observium Community.