This object controls the sending of a Bit Error
Rate (BER) alarm. The possible values are:
VALUE DESCRIPTION
acBerAlmEnable(1) Enable sending BER alarms
acBerAlmDisable(2) Disable sending BER alarms
Parsed from file datasmartmax.mi9b.mib.txt
Company: adc_kentrox
Module: DSMAX-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
dsMAcBerAlm OBJECT-TYPE SYNTAX INTEGER { acBerAlmEnable (1), acBerAlmDisable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object controls the sending of a Bit Error Rate (BER) alarm. The possible values are: VALUE DESCRIPTION acBerAlmEnable(1) Enable sending BER alarms acBerAlmDisable(2) Disable sending BER alarms" ::= { dsMAc 8 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.181.2.1.5.8.0 | dsMAcBerAlm | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.181.2.1.5.1 | dsMAcAlmMsg | 1 | 1 | This object controls the displaying/sending of alarm messages. Alarm messages will be sent in the format determined by dsMAcAlmFo… |
1.3.6.1.4.1.181.2.1.5.2 | dsMAcAlmFormat | 1 | 1 | This object determines what format alarm messages are sent in. ASCII alarm strings will be sent if this object is set to acAlmFor… |
1.3.6.1.4.1.181.2.1.5.3 | dsMAcYelAlm | 1 | 1 | This object determines if incoming Yellow Alarm will cause an alarm message to be sent. Setting this object to acYelAlmEnable(1) … |
1.3.6.1.4.1.181.2.1.5.4 | dsMAcDeact | 1 | 1 | This object controls the number of seconds an alarm condition must remain clear before the unit declares it cleared. The range is… |
1.3.6.1.4.1.181.2.1.5.5 | dsMAcEst | 1 | 1 | This object determines the threshold of errored seconds that triggers an Excessive Error Rate (EER) alarm. Setting this object to… |
1.3.6.1.4.1.181.2.1.5.6 | dsMAcUst | 1 | 1 | This object determines the threshold of uavailable seconds that triggers an Excessive Error Rate (EER) alarm. Setting this object… |
1.3.6.1.4.1.181.2.1.5.7 | dsMAcSt | 1 | 1 | This object determines the window used to calculate whether an Excessive Error Rate (EER) alarm should be generated from errored … |
1.3.6.1.4.1.181.2.1.5.9 | dsMAcRfaAlm | 1 | 1 | This object controls the sending of a Remote Frame Alarm (RFA). The possible values are: VALUE DESCRIPTION acRfaAlmE… |
1.3.6.1.4.1.181.2.1.5.10 | dsMAcAisAlm | 1 | 1 | This object controls the sending of Alarm Indication Signal (AIS) alarms. The possible values are: VALUE DESCRIPTIO… |