Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwVOPSNRMarginConfProfUsTimeDs",
"OBJECT-TYPE",
"SYNTAX",
"Gauge32",
"(",
"0",
".",
".",
"16383",
")",
"UNITS",
[
"literal",
"227365636f6e647322"
],
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The Downstream Up-Shift Time Interval, to be used when hwVOPSNRMarginConfProfRaModeDs is set to dynamicRa. The interval of time that the downstream noise margin should stay above the Downstream Up-Shift Noise Margin before the xTU-R shall attempt to increase the downstream net data rate. The time interval ranges from 0 to 16383 seconds. Unit: seconds. \"",
"REFERENCE",
"\"ITU-T G.997.1, paragraph #7.3.1.4.5 (RA-UTIMEds)\"",
"DEFVAL",
"{",
"3600",
"}",
"::=",
"{",
"hwVOPSNRMarginConfProfEntry",
"18",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Gauge32",
[
"integerSubType",
[
[
0,
16383
]
]
]
],
[
"UNITS",
"seconds"
],
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The Downstream Up-Shift Time Interval, to be used when hwVOPSNRMarginConfProfRaModeDs is set to dynamicRa. The interval of time that the downstream noise margin should stay above the Downstream Up-Shift Noise Margin before the xTU-R shall attempt to increase the downstream net data rate. The time interval ranges from 0 to 16383 seconds. Unit: seconds."
],
[
"REFERENCE",
"ITU-T G.997.1, paragraph #7.3.1.4.5 (RA-UTIMEds)"
],
null,
null,
[
"DEFVAL",
3600
]
]
}