Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwVOPGfastSNRMarginConfProfRaUsNrmDs",
"OBJECT-TYPE",
"SYNTAX",
"Gauge32",
"(",
"0",
".",
".",
"310",
")",
"UNITS",
[
"literal",
"22302e3120644222"
],
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The G.fast Downstream Up-Shift Noise Margin value, to be used when hwVOPGfastSNRMarginConfProfRaModeDs is set to dynamicRa. If the downstream noise margin is above this value, and stays above it for more than the time specified by the hwVOPGfastSNRMarginConfProfUsTimeDs, the xTU-R shall attempt to increase the Downstream net data rate. The Downstream Up-Shift Noise Margin ranges from 0 to 310 units of 0.1 dB (Physical values are 0 to 31 dB). Unit: 0.1 dB. \"",
"REFERENCE",
"\"ITU-T G.9701, paragraph 12.3.4.2.1\"",
"DEFVAL",
"{",
"120",
"}",
"::=",
"{",
"hwVOPSNRMarginConfProfEntry",
"32",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Gauge32",
[
"integerSubType",
[
[
0,
310
]
]
]
],
[
"UNITS",
"0.1 dB"
],
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The G.fast Downstream Up-Shift Noise Margin value, to be used when hwVOPGfastSNRMarginConfProfRaModeDs is set to dynamicRa. If the downstream noise margin is above this value, and stays above it for more than the time specified by the hwVOPGfastSNRMarginConfProfUsTimeDs, the xTU-R shall attempt to increase the Downstream net data rate. The Downstream Up-Shift Noise Margin ranges from 0 to 310 units of 0.1 dB (Physical values are 0 to 31 dB). Unit: 0.1 dB."
],
[
"REFERENCE",
"ITU-T G.9701, paragraph 12.3.4.2.1"
],
null,
null,
[
"DEFVAL",
120
]
]
}