Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwVOPGfastSNRMarginConfProfMinSnrmRmcUs",
"OBJECT-TYPE",
"SYNTAX",
"Gauge32",
"(",
"0",
".",
".",
"310",
")",
"UNITS",
[
"literal",
"22302e3120644222"
],
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"Defines the upstream minimum noise margin the FTU-O receiver tolerates for the RMC. If the downstream RMC noise margin falls below this level, the FTU-O initiates the RPA procedure. The minimum noise margin ranges from 0 to 310 units of 0.1 dB (Physical values are 0 to 31 dB). A value of 0 means that there is no minimum. Unit: 0.1 dB. \"",
"REFERENCE",
"\"ITU-T G.997.2, paragraph 7.1.6.4\"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"hwVOPSNRMarginConfProfEntry",
"43",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Gauge32",
[
"integerSubType",
[
[
0,
310
]
]
]
],
[
"UNITS",
"0.1 dB"
],
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Defines the upstream minimum noise margin the FTU-O receiver tolerates for the RMC. If the downstream RMC noise margin falls below this level, the FTU-O initiates the RPA procedure. The minimum noise margin ranges from 0 to 310 units of 0.1 dB (Physical values are 0 to 31 dB). A value of 0 means that there is no minimum. Unit: 0.1 dB."
],
[
"REFERENCE",
"ITU-T G.997.2, paragraph 7.1.6.4"
],
null,
null,
[
"DEFVAL",
0
]
]
}