Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwVOPGfastINPDelayConfProfIatReinRtxDs",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"frequency100Hz",
"(",
"0",
")",
",",
"frequency120Hz",
"(",
"1",
")",
",",
"frequency300Hz",
"(",
"2",
")",
",",
"frequency360Hz",
"(",
"3",
")",
"}",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"This parameter specifies the G.fast downstream inter-arrival time that shall be assumed for REIN protection. Options: 1. frequency100Hz(0) - an inter-arrival time derived from a REIN at 100 Hz 2. frequency120Hz(1) - an inter-arrival time derived from a REIN at 120 Hz 3. frequency300Hz(2) - an inter-arrival time derived from a REIN at 300 Hz 4. frequency360Hz(3) - an inter-arrival time derived from a REIN at 360 Hz \"",
"REFERENCE",
"\"ITU-T G.9701, paragraph 11.4.2.9\"",
"DEFVAL",
"{",
"frequency100Hz",
"}",
"::=",
"{",
"hwVOPINPDelayConfProfEntry",
"37",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"frequency100Hz",
0
],
[
"frequency120Hz",
1
],
[
"frequency300Hz",
2
],
[
"frequency360Hz",
3
]
]
]
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This parameter specifies the G.fast downstream inter-arrival time that shall be assumed for REIN protection. Options: 1. frequency100Hz(0) - an inter-arrival time derived from a REIN at 100 Hz 2. frequency120Hz(1) - an inter-arrival time derived from a REIN at 120 Hz 3. frequency300Hz(2) - an inter-arrival time derived from a REIN at 300 Hz 4. frequency360Hz(3) - an inter-arrival time derived from a REIN at 360 Hz"
],
[
"REFERENCE",
"ITU-T G.9701, paragraph 11.4.2.9"
],
null,
null,
[
"DEFVAL",
"frequency100Hz"
]
]
}