Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwSlotAdminStatus",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"nooperation",
"(",
"-",
"1",
")",
",",
"disable",
"(",
"1",
")",
",",
"enable",
"(",
"2",
")",
",",
"reset",
"(",
"3",
")",
",",
"test",
"(",
"4",
")",
",",
"confirm",
"(",
"5",
")",
",",
"switch",
"(",
"6",
")",
",",
"delete",
"(",
"7",
")",
",",
"forbidden",
"(",
"8",
")",
",",
"unforbidden",
"(",
"9",
")",
",",
"endservice",
"(",
"10",
")",
",",
"startservice",
"(",
"11",
")",
",",
"poweron",
"(",
"12",
")",
",",
"poweroff",
"(",
"13",
")",
",",
"is",
"(",
"14",
")",
",",
"oos",
"(",
"15",
")",
",",
"hotreset",
"(",
"16",
")",
"}",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\" Board status management. This object cannot be set simultaneously with hwSlotRowStatus or hwSlotWorkMode. Options: 1. nooperation(-1) -default state of the system 2. disable(1) -disable the running of a board 3. enable(2) -enable the running of a board 4. reset(3) -reset a board 5. test(4) -test a board 6. confirm(5) -confirm the board in the discovery(5) state in hwSlotOperStatus After the operation, the board is in the config state 7. switch(6) -main board switchover on access network UA device 8. delete(7) -delete a board 9. forbidden(8) -forbid a board 10.unforbidden(9) -permit a board 11.endservice(10) -used in the exit delay of a board 12.startservice(11) -used in the exit delay of a board 13.poweron(12) -used to power on a board 14.poweroff(13) -used to power off a board 15.is(14) -in service 16.oos(15) -out of service 17.hotreset(16) -hotreset a board \"",
"::=",
"{",
"hwSlotEntry",
"9",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"nooperation",
-1
],
[
"disable",
1
],
[
"enable",
2
],
[
"reset",
3
],
[
"test",
4
],
[
"confirm",
5
],
[
"switch",
6
],
[
"delete",
7
],
[
"forbidden",
8
],
[
"unforbidden",
9
],
[
"endservice",
10
],
[
"startservice",
11
],
[
"poweron",
12
],
[
"poweroff",
13
],
[
"is",
14
],
[
"oos",
15
],
[
"hotreset",
16
]
]
]
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Board status management. This object cannot be set simultaneously with hwSlotRowStatus or hwSlotWorkMode. Options: 1. nooperation(-1) -default state of the system 2. disable(1) -disable the running of a board 3. enable(2) -enable the running of a board 4. reset(3) -reset a board 5. test(4) -test a board 6. confirm(5) -confirm the board in the discovery(5) state in hwSlotOperStatus After the operation, the board is in the config state 7. switch(6) -main board switchover on access network UA device 8. delete(7) -delete a board 9. forbidden(8) -forbid a board 10.unforbidden(9) -permit a board 11.endservice(10) -used in the exit delay of a board 12.startservice(11) -used in the exit delay of a board 13.poweron(12) -used to power on a board 14.poweroff(13) -used to power off a board 15.is(14) -in service 16.oos(15) -out of service 17.hotreset(16) -hotreset a board"
],
null,
null,
null,
null
]
}