Physical Drive Vendor.
This is the name of the manufacturer of the physical drive.
This value is based upon the vendor name as returned by the
SCSI inquiry command but may have been modified due to space
limitations. This can be used for identification purposes.
Parsed from file CPQCR1.MIB.txt
Company: None
Module: CPQCR-MIB
Physical Drive Vendor.
This is the name of the manufacturer of the physical drive.
This value is based upon the vendor name as returned by the
SCSI inquiry command but may have been modified due to space
limitations. This can be used for identification purposes.
Parsed from file CPQCR-MIB.mib
Module: CPQCR-MIB
cpqCrPhyDrvVendor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Physical Drive Vendor. This is the name of the manufacturer of the physical drive. This value is based upon the vendor name as returned by the SCSI inquiry command but may have been modified due to space limitations. This can be used for identification purposes." ::= { cpqCrPhyDrvEntry 3 }
Vendor: Compaq
Module: CPQCR-MIB
[Automatically extracted from oidview.com]
cpqCrPhyDrvVendor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Physical Drive Vendor. This is the name of the manufacturer of the physical drive. This value is based upon the vendor name as returned by the SCSI inquiry command but may have been modified due to space limitations. This can be used for identification purposes." ::= { cpqCrPhyDrvEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.141.2.5.1.1.1 | cpqCrPhyDrvCntlrIndex | 0 | 0 | Clustered RAID Physical Drive Controller Index. This index maps the physical drive back to the controller to which it is attached… |
1.3.6.1.4.1.232.141.2.5.1.1.2 | cpqCrPhyDrvIndex | 0 | 0 | Clustered RAID Physical Drive Index. This index is used for selecting the physical drive table entry. This number, along with the… |
1.3.6.1.4.1.232.141.2.5.1.1.4 | cpqCrPhyDrvModel | 0 | 0 | Physical Drive Model. This is a text description of the physical drive. The text that appears depends upon who manufactured the … |
1.3.6.1.4.1.232.141.2.5.1.1.5 | cpqCrPhyDrvRevision | 0 | 0 | Physical Drive Revision. This shows the physical drive revision number. |
1.3.6.1.4.1.232.141.2.5.1.1.6 | cpqCrPhyDrvStatus | 0 | 0 | Physical Drive Status. This shows the status of the physical drive. The following values are valid for the physical drive status:… |
1.3.6.1.4.1.232.141.2.5.1.1.7 | cpqCrPhyDrvSize | 0 | 0 | Physical Drive Size in MB. This is the size of the physical drive in megabytes. This value is calculated using the value 1,048,5… |
1.3.6.1.4.1.232.141.2.5.1.1.8 | cpqCrPhyDrvCondition | 0 | 0 | Physical Drive condition. This value represents the overall condition of this physical drive. |
1.3.6.1.4.1.232.141.2.5.1.1.9 | cpqCrPhyDrvScsiID | 0 | 0 | SCSI ID. This value represents the SCSI identifier of this physical drive. |