Physical Drive Model.
This is a text description of the physical drive. The text that
appears depends upon who manufactured the drive and the drive
type.
For example, you might see: CP3201.
If a drive fails, note the model to identify the type of drive
necessary for replacement.
Parsed from file CPQCR1.MIB.txt
Company: None
Module: CPQCR-MIB
Physical Drive Model.
This is a text description of the physical drive. The text that
appears depends upon who manufactured the drive and the drive
type.
For example, you might see: CP3201.
If a drive fails, note the model to identify the type of drive
necessary for replacement.
Parsed from file CPQCR-MIB.mib
Module: CPQCR-MIB
cpqCrPhyDrvModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Physical Drive Model. This is a text description of the physical drive. The text that appears depends upon who manufactured the drive and the drive type. For example, you might see: CP3201. If a drive fails, note the model to identify the type of drive necessary for replacement." ::= { cpqCrPhyDrvEntry 4 }
Vendor: Compaq
Module: CPQCR-MIB
[Automatically extracted from oidview.com]
cpqCrPhyDrvModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Physical Drive Model. This is a text description of the physical drive. The text that appears depends upon who manufactured the drive and the drive type. For example, you might see: CP3201. If a drive fails, note the model to identify the type of drive necessary for replacement." ::= { cpqCrPhyDrvEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.141.2.5.1.1.1 | cpqCrPhyDrvCntlrIndex | 0 | 0 | Clustered RAID Physical Drive Controller Index. This index maps the physical drive back to the controller to which it is attached… |
1.3.6.1.4.1.232.141.2.5.1.1.2 | cpqCrPhyDrvIndex | 0 | 0 | Clustered RAID Physical Drive Index. This index is used for selecting the physical drive table entry. This number, along with the… |
1.3.6.1.4.1.232.141.2.5.1.1.3 | cpqCrPhyDrvVendor | 0 | 0 | Physical Drive Vendor. This is the name of the manufacturer of the physical drive. This value is based upon the vendor name as re… |
1.3.6.1.4.1.232.141.2.5.1.1.5 | cpqCrPhyDrvRevision | 0 | 0 | Physical Drive Revision. This shows the physical drive revision number. |
1.3.6.1.4.1.232.141.2.5.1.1.6 | cpqCrPhyDrvStatus | 0 | 0 | Physical Drive Status. This shows the status of the physical drive. The following values are valid for the physical drive status:… |
1.3.6.1.4.1.232.141.2.5.1.1.7 | cpqCrPhyDrvSize | 0 | 0 | Physical Drive Size in MB. This is the size of the physical drive in megabytes. This value is calculated using the value 1,048,5… |
1.3.6.1.4.1.232.141.2.5.1.1.8 | cpqCrPhyDrvCondition | 0 | 0 | Physical Drive condition. This value represents the overall condition of this physical drive. |
1.3.6.1.4.1.232.141.2.5.1.1.9 | cpqCrPhyDrvScsiID | 0 | 0 | SCSI ID. This value represents the SCSI identifier of this physical drive. |