A table entry for a Subsystem
Parsed from file cpqappg80.mib.txt
Company: compaq
Module: CPQAPPG80-MIB
cpqSMASubsystemEntry OBJECT-TYPE SYNTAX cpqSMASubsystemEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table entry for a Subsystem" INDEX { cpqSMASubsystemIndex } ::= { cpqSMASubsystemTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.151.100.2.1.1.1 | cpqSMASubsystemIndex | 0 | 0 | The Subsystem index |
1.3.6.1.4.1.232.151.100.2.1.1.2 | cpqSMASubsystemName | 0 | 0 | The name of the Subsystem. |
1.3.6.1.4.1.232.151.100.2.1.1.3 | cpqSMASubsystemControllerOne | 0 | 0 | The index of controller one thats belongs to this subsytem. If the value is -1 then either the controller is not installed or not… |
1.3.6.1.4.1.232.151.100.2.1.1.4 | cpqSMASubsystemControllerTwo | 0 | 0 | The index of controller two thats belongs to this subsytem. If the value is -1 then either the controller is not installed or not… |
1.3.6.1.4.1.232.151.100.2.1.1.5 | cpqSMASubsystemEMUState | 0 | 0 | Subsystem Environmental Monitoring Unit (EMU) State. nooper(1) - EMU is either not installed or not operational. oper(2) - EMU i… |
1.3.6.1.4.1.232.151.100.2.1.1.6 | cpqSMASubsystemEMUVersion | 0 | 0 | Subsystem Environmental Monitoring Unit (EMU) Microcode verion. |
1.3.6.1.4.1.232.151.100.2.1.1.7 | cpqSMASubsystemEMUSensor1 | 0 | 0 | Subsystem Environmental Monitoring Unit (EMU) Sensor1 value (in Celsius). Sensor1 sets the maximum operating temperature for the… |
1.3.6.1.4.1.232.151.100.2.1.1.8 | cpqSMASubsystemEMUSensor2 | 0 | 0 | Subsystem Environmental Monitoring Unit (EMU) Sensor2 value (in Celsius). Sensor2 also sets the maximum operating temperature f… |
1.3.6.1.4.1.232.151.100.2.1.1.9 | cpqSMASubsystemEMUSensor3 | 0 | 0 | Subsystem Environmental Monitoring Unit (EMU) Sensor3 value (in Celsius). Sensor3 sets the maximum operating temperature for the… |
1.3.6.1.4.1.232.151.100.2.1.1.10 | cpqSMASubsystemEMUFanspeed | 0 | 0 | Subsystem Fanspeed. FANSPEED=HIGH forces the fans in all connected cabinets to operate at high speed continuously. FANSPEED=AUTO… |
1.3.6.1.4.1.232.151.100.2.1.1.11 | cpqSMASubsystemEMUAlarm | 0 | 0 | Subsystem Environmental Monitoring Unit Alarm. Determines whether or not the audible alarm of the EMU will sound in the following… |
1.3.6.1.4.1.232.151.100.2.1.1.12 | cpqSMASubsystemState | 0 | 0 | Gives us the overall state of the HSG80 subsystem. |
1.3.6.1.4.1.232.151.100.2.1.1.13 | cpqSMASubsystemAlias | 0 | 0 | The Subsystem Alias. |