Subsystem Fanspeed.
FANSPEED=HIGH forces the fans in all connected cabinets to operate at
high speed continuously.
FANSPEED=AUTOMATIC allows the EMU to control the fan speed for
the fans in all connected cabinets.
The EMU instructs the fans to operate at high speed when any of the temperature
setpoints are exceeded or when one or more fans are not functioning.
Parsed from file cpqappg80.mib.txt
Company: compaq
Module: CPQAPPG80-MIB
cpqSMASubsystemEMUFanspeed OBJECT-TYPE SYNTAX INTEGER { high(1), automatic(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Subsystem Fanspeed. FANSPEED=HIGH forces the fans in all connected cabinets to operate at high speed continuously. FANSPEED=AUTOMATIC allows the EMU to control the fan speed for the fans in all connected cabinets. The EMU instructs the fans to operate at high speed when any of the temperature setpoints are exceeded or when one or more fans are not functioning." ::= { cpqSMASubsystemEntry 10 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.151.100.2.1.1.1 | cpqSMASubsystemIndex | 0 | 0 | The Subsystem index |
1.3.6.1.4.1.232.151.100.2.1.1.2 | cpqSMASubsystemName | 0 | 0 | The name of the Subsystem. |
1.3.6.1.4.1.232.151.100.2.1.1.3 | cpqSMASubsystemControllerOne | 0 | 0 | The index of controller one thats belongs to this subsytem. If the value is -1 then either the controller is not installed or not… |
1.3.6.1.4.1.232.151.100.2.1.1.4 | cpqSMASubsystemControllerTwo | 0 | 0 | The index of controller two thats belongs to this subsytem. If the value is -1 then either the controller is not installed or not… |
1.3.6.1.4.1.232.151.100.2.1.1.5 | cpqSMASubsystemEMUState | 0 | 0 | Subsystem Environmental Monitoring Unit (EMU) State. nooper(1) - EMU is either not installed or not operational. oper(2) - EMU i… |
1.3.6.1.4.1.232.151.100.2.1.1.6 | cpqSMASubsystemEMUVersion | 0 | 0 | Subsystem Environmental Monitoring Unit (EMU) Microcode verion. |
1.3.6.1.4.1.232.151.100.2.1.1.7 | cpqSMASubsystemEMUSensor1 | 0 | 0 | Subsystem Environmental Monitoring Unit (EMU) Sensor1 value (in Celsius). Sensor1 sets the maximum operating temperature for the… |
1.3.6.1.4.1.232.151.100.2.1.1.8 | cpqSMASubsystemEMUSensor2 | 0 | 0 | Subsystem Environmental Monitoring Unit (EMU) Sensor2 value (in Celsius). Sensor2 also sets the maximum operating temperature f… |
1.3.6.1.4.1.232.151.100.2.1.1.9 | cpqSMASubsystemEMUSensor3 | 0 | 0 | Subsystem Environmental Monitoring Unit (EMU) Sensor3 value (in Celsius). Sensor3 sets the maximum operating temperature for the… |
1.3.6.1.4.1.232.151.100.2.1.1.11 | cpqSMASubsystemEMUAlarm | 0 | 0 | Subsystem Environmental Monitoring Unit Alarm. Determines whether or not the audible alarm of the EMU will sound in the following… |
1.3.6.1.4.1.232.151.100.2.1.1.12 | cpqSMASubsystemState | 0 | 0 | Gives us the overall state of the HSG80 subsystem. |
1.3.6.1.4.1.232.151.100.2.1.1.13 | cpqSMASubsystemAlias | 0 | 0 | The Subsystem Alias. |