Reference record for OID 1.3.6.1.4.1.232.16.2.4.1.1.2



parent
1.3.6.1.4.1.232.16.2.4.1.1 (cpqFcaSpareEntry)
node code
2
node name
cpqFcaSparePhyDrvIndex
dot oid
1.3.6.1.4.1.232.16.2.4.1.1.2
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaSpareDrv(4) cpqFcaSpareTable(1) cpqFcaSpareEntry(1) cpqFcaSparePhyDrvIndex(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaSpareDrv(4) cpqFcaSpareTable(1) cpqFcaSpareEntry(1) cpqFcaSparePhyDrvIndex(2)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaSpareDrv(4) cpqFcaSpareTable(1) cpqFcaSpareEntry(1) cpqFcaSparePhyDrvIndex(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaSpareDrv(4) cpqFcaSpareTable(1) cpqFcaSpareEntry(1) cpqFcaSparePhyDrvIndex(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaSpareDrv(4) cpqFcaSpareTable(1) cpqFcaSpareEntry(1) cpqFcaSparePhyDrvIndex(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaSpareDrv(4) cpqFcaSpareTable(1) cpqFcaSpareEntry(1) cpqFcaSparePhyDrvIndex(2)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaSpareDrv(4) cpqFcaSpareTable(1) cpqFcaSpareEntry(1) cpqFcaSparePhyDrvIndex(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaSpareDrv(4) cpqFcaSpareTable(1) cpqFcaSpareEntry(1) cpqFcaSparePhyDrvIndex(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaSpareDrv/cpqFcaSpareTable/cpqFcaSpareEntry/cpqFcaSparePhyDrvIndex
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqFibreArray/cpqFcaComponent/cpqFcaSpareDrv/cpqFcaSpareTable/cpqFcaSpareEntry/cpqFcaSparePhyDrvIndex
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaSpareDrv/cpqFcaSpareTable/cpqFcaSpareEntry/cpqFcaSparePhyDrvIndex
  • /iso/org/dod/internet/private/enterprise/hp/cpqFibreArray/cpqFcaComponent/cpqFcaSpareDrv/cpqFcaSpareTable/cpqFcaSpareEntry/cpqFcaSparePhyDrvIndex
  • /iso/org/dod/internet/private/enterprises/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaSpareDrv/cpqFcaSpareTable/cpqFcaSpareEntry/cpqFcaSparePhyDrvIndex
  • /iso/org/dod/internet/private/enterprises/hp/cpqFibreArray/cpqFcaComponent/cpqFcaSpareDrv/cpqFcaSpareTable/cpqFcaSpareEntry/cpqFcaSparePhyDrvIndex
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaSpareDrv/cpqFcaSpareTable/cpqFcaSpareEntry/cpqFcaSparePhyDrvIndex
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqFibreArray/cpqFcaComponent/cpqFcaSpareDrv/cpqFcaSpareTable/cpqFcaSpareEntry/cpqFcaSparePhyDrvIndex
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/232/16/2/4/1/1/2

    Description by mibdepot

    Fibre Channel Array Spare Physical Drive Index.

    This index maps the spare to the physical drive it represents.
    The value of this index is the same as the one used with the
    physical drive table.

    Parsed from file CPQFCA2.MIB.txt
    Company: None
    Module: CPQFCA-MIB

    Description by circitor

    External Array Spare Physical Drive Index.

    This index maps the spare to the physical drive it represents.
    The value of this index is the same as the one used with the
    physical drive table.

    Parsed from file CPQFCA-MIB.mib
    Module: CPQFCA-MIB

    Information by mibdepot

    cpqFcaSparePhyDrvIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Fibre Channel Array Spare Physical Drive Index. This index maps the spare to the physical drive it represents. The value of this index is the same as the one used with the physical drive table." ::= { cpqFcaSpareEntry 2 }

    Information by oid_info

    Vendor: Compaq
    Module: CPQFCA-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cpqFcaSparePhyDrvIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "External Array Spare Physical Drive Index. This index maps the spare to the physical drive it represents. The value of this index is the same as the one used with the physical drive table." ::= { cpqFcaSpareEntry 2 }

    Brothers (9)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.16.2.4.1.1.1 cpqFcaSpareBoxIndex 0 0 External Array Spare Drive Storage Box Index.

    The storage box index indicates which storage box this spare
    drive is in.
    1.3.6.1.4.1.232.16.2.4.1.1.3 cpqFcaSpareStatus 0 0 Spare Status.

    This shows the status of the on-line spare drive.

    The following values are valid for the spare status:

    Inactive (2)
    T…
    1.3.6.1.4.1.232.16.2.4.1.1.4 cpqFcaSpareReplacedDrvBay 0 0 Spare Replaced Drive Bay.

    If the spare status is active(6) or building(5), then this
    has the physical drive bay number of the rep…
    1.3.6.1.4.1.232.16.2.4.1.1.5 cpqFcaSparePercentRebuild 0 0 External Array Spare Percent Rebuild.

    If the spare status is building(5), then this is percent
    complete of of the rebuild.

    The dat…
    1.3.6.1.4.1.232.16.2.4.1.1.6 cpqFcaSpareCondition 0 0 The Spare Drive condition.

    This value represents the overall condition of this spare drive
    and any associated physical drives.
    1.3.6.1.4.1.232.16.2.4.1.1.7 cpqFcaSpareBusNumber 0 0 Spare Drive SCSI Bus Number.

    The bus number indicates to which SCSI bus this spare drive
    is attached. The first instance is one …
    1.3.6.1.4.1.232.16.2.4.1.1.8 cpqFcaSpareBay 0 0 External Array Spare Drive Bay Location.

    This value matches the bay location where the physical drive has
    been installed. Each b…
    1.3.6.1.4.1.232.16.2.4.1.1.9 cpqFcaSpareReplacedDrvBusNumber 0 0 Spare Replaced Drive Bus Number.

    If the spare status is active(6) or building(5), then this
    has the physical drive bus number of …
    1.3.6.1.4.1.232.16.2.4.1.1.10 cpqFcaSpareLocationString 0 0 Spare Drive Location String.

    This string describes the location of the drive in relation to
    the storage box. If the location str…