Spare Status.
This shows the status of the on-line spare drive.
The following values are valid for the spare status:
Inactive (2)
The monitored system has an on-line spare configured, but is
not currently in use.
Failed (3)
The on-line spare has failed and is no longer available for use.
Building (4)
A physical drive has failed. Automatic Data Recovery
is in progress to recover data to the on-line spare.
Active (5)
A physical drive has failed. Automatic Data Recovery is
complete. The system is using the on-line spare as a
replacement for the failed drive.
Parsed from file CPQFCA2.MIB.txt
Company: None
Module: CPQFCA-MIB
Spare Status.
This shows the status of the on-line spare drive.
The following values are valid for the spare status:
Inactive (2)
The monitored system has an on-line spare configured, but is
not currently in use.
Failed (3)
The on-line spare has failed and is no longer available for use.
Building (4)
A physical drive has failed. Automatic Data Recovery
is in progress to recover data to the on-line spare.
Active (5)
A physical drive has failed. Automatic Data Recovery is
complete. The system is using the on-line spare as a
replacement for the failed drive.
Parsed from file CPQFCA-MIB.mib
Module: CPQFCA-MIB
cpqFcaSpareStatus OBJECT-TYPE SYNTAX INTEGER { other(1), inactive(2), failed(3), building(4), active(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Spare Status. This shows the status of the on-line spare drive. The following values are valid for the spare status: Inactive (2) The monitored system has an on-line spare configured, but is not currently in use. Failed (3) The on-line spare has failed and is no longer available for use. Building (4) A physical drive has failed. Automatic Data Recovery is in progress to recover data to the on-line spare. Active (5) A physical drive has failed. Automatic Data Recovery is complete. The system is using the on-line spare as a replacement for the failed drive." ::= { cpqFcaSpareEntry 3 }
Vendor: Compaq
Module: CPQFCA-MIB
[Automatically extracted from oidview.com]
cpqFcaSpareStatus OBJECT-TYPE SYNTAX INTEGER { other(1), inactive(2), failed(3), building(4), active(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Spare Status. This shows the status of the on-line spare drive. The following values are valid for the spare status: Inactive (2) The monitored system has an on-line spare configured, but is not currently in use. Failed (3) The on-line spare has failed and is no longer available for use. Building (4) A physical drive has failed. Automatic Data Recovery is in progress to recover data to the on-line spare. Active (5) A physical drive has failed. Automatic Data Recovery is complete. The system is using the on-line spare as a replacement for the failed drive." ::= { cpqFcaSpareEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.16.2.4.1.1.1 | cpqFcaSpareBoxIndex | 0 | 0 | External Array Spare Drive Storage Box Index. The storage box index indicates which storage box this spare drive is in. |
1.3.6.1.4.1.232.16.2.4.1.1.2 | cpqFcaSparePhyDrvIndex | 0 | 0 | External Array Spare Physical Drive Index. This index maps the spare to the physical drive it represents. The value of this index… |
1.3.6.1.4.1.232.16.2.4.1.1.4 | cpqFcaSpareReplacedDrvBay | 0 | 0 | Spare Replaced Drive Bay. If the spare status is active(6) or building(5), then this has the physical drive bay number of the rep… |
1.3.6.1.4.1.232.16.2.4.1.1.5 | cpqFcaSparePercentRebuild | 0 | 0 | External Array Spare Percent Rebuild. If the spare status is building(5), then this is percent complete of of the rebuild. The dat… |
1.3.6.1.4.1.232.16.2.4.1.1.6 | cpqFcaSpareCondition | 0 | 0 | The Spare Drive condition. This value represents the overall condition of this spare drive and any associated physical drives. |
1.3.6.1.4.1.232.16.2.4.1.1.7 | cpqFcaSpareBusNumber | 0 | 0 | Spare Drive SCSI Bus Number. The bus number indicates to which SCSI bus this spare drive is attached. The first instance is one … |
1.3.6.1.4.1.232.16.2.4.1.1.8 | cpqFcaSpareBay | 0 | 0 | External Array Spare Drive Bay Location. This value matches the bay location where the physical drive has been installed. Each b… |
1.3.6.1.4.1.232.16.2.4.1.1.9 | cpqFcaSpareReplacedDrvBusNumber | 0 | 0 | Spare Replaced Drive Bus Number. If the spare status is active(6) or building(5), then this has the physical drive bus number of … |
1.3.6.1.4.1.232.16.2.4.1.1.10 | cpqFcaSpareLocationString | 0 | 0 | Spare Drive Location String. This string describes the location of the drive in relation to the storage box. If the location str… |