Reference record for OID 1.3.6.1.4.1.232.165.5.2.1.1



parent
1.3.6.1.4.1.232.165.5.2.1 (mpduOutputTable)
node code
1
node name
mpduOutputEntry
dot oid
1.3.6.1.4.1.232.165.5.2.1.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqPower(165) trapTest(5) mpduOutput(2) mpduOutputTable(1) mpduOutputEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqPower(165) mpdu(5) mpduOutput(2) mpduOutputTable(1) mpduOutputEntry(1)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqPower(165) trapTest(5) mpduOutput(2) mpduOutputTable(1) mpduOutputEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqPower(165) mpdu(5) mpduOutput(2) mpduOutputTable(1) mpduOutputEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqPower(165) trapTest(5) mpduOutput(2) mpduOutputTable(1) mpduOutputEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqPower(165) mpdu(5) mpduOutput(2) mpduOutputTable(1) mpduOutputEntry(1)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqPower(165) trapTest(5) mpduOutput(2) mpduOutputTable(1) mpduOutputEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqPower(165) mpdu(5) mpduOutput(2) mpduOutputTable(1) mpduOutputEntry(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqPower/trapTest/mpduOutput/mpduOutputTable/mpduOutputEntry
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqPower/mpdu/mpduOutput/mpduOutputTable/mpduOutputEntry
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/hp/cpqPower/trapTest/mpduOutput/mpduOutputTable/mpduOutputEntry
  • /iso/org/dod/internet/private/enterprise/hp/cpqPower/mpdu/mpduOutput/mpduOutputTable/mpduOutputEntry
  • /iso/org/dod/internet/private/enterprises/compaq/cpqPower/trapTest/mpduOutput/mpduOutputTable/mpduOutputEntry
  • /iso/org/dod/internet/private/enterprises/compaq/cpqPower/mpdu/mpduOutput/mpduOutputTable/mpduOutputEntry
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqPower/trapTest/mpduOutput/mpduOutputTable/mpduOutputEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqPower/mpdu/mpduOutput/mpduOutputTable/mpduOutputEntry
  • Description by mibdepot

    The output table entry containing the voltage, current, PF,
    percent load, VA, Watts for the Modular PDU.

    Parsed from file CPQPOWER1.62.MIB.txt
    Company: compaq
    Module: CPQPOWER-MIB

    Information by mibdepot

    mpduOutputEntry OBJECT-TYPE SYNTAX MpduOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The output table entry containing the voltage, current, PF, percent load, VA, Watts for the Modular PDU." INDEX { mpduIdentIndex, mpduOutputIndex } ::= { mpduOutputTable 1 }

    Children (12)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.165.5.2.1.1.1 mpduOutputIndex 0 0 Index for the MpduOutputEntry table.
    1.3.6.1.4.1.232.165.5.2.1.1.2 mpduOutputStatus 0 0 The overall status of the device: off, on, problem.
    1.3.6.1.4.1.232.165.5.2.1.1.3 mpduOutputBreakerRating 0 0 The rating of each MPDU Output in Ampere.
    1.3.6.1.4.1.232.165.5.2.1.1.4 mpduOutputSmartDevice 0 0 A smart cord device detected: False, True.
    1.3.6.1.4.1.232.165.5.2.1.1.5 mpduOutputPercentLoad 0 0 The MPDU's each output load in percent of rated capacity. Value is
    presented in 1/10 of the percentage i.e. 125 is 12.5%. A val…
    1.3.6.1.4.1.232.165.5.2.1.1.6 mpduOutputVoltage 0 0 The measured output voltage from the PDU meters in volts. Value is
    presented in 1/10 of the Volt i.e. 2095 is 209.5 V. A value
    o…
    1.3.6.1.4.1.232.165.5.2.1.1.7 mpduOutputCurrent 0 0 The measured output current from the PDU meters in amps. Value is
    presented in 1/100 of the Ampere i.e. 175 is 1.75 A. A value
    o…
    1.3.6.1.4.1.232.165.5.2.1.1.8 mpduOutputPowerVA 0 0 The total VA load (VI) measured on the PDU in VA. A value
    of -1 will be returned if the power is unable to be calculated.
    1.3.6.1.4.1.232.165.5.2.1.1.9 mpduOutputPowerWatt 0 0 The total power load measured on the PDU in Watts. A value
    of -1 will be returned if the power is unable to be calculated.
    1.3.6.1.4.1.232.165.5.2.1.1.10 mpduOutputPowerFactor 0 0 The power factor is presented in 1/100 of the unit i.e.
    98 is 0.98. A value of -1 will be returned if the power factor is unabl…
    1.3.6.1.4.1.232.165.5.2.1.1.11 mpduOutputWarningThreshold 0 0 Report the User-set threshhold limit for Warning in percentage
    1.3.6.1.4.1.232.165.5.2.1.1.12 mpduOutputCriticalThreshold 0 0 Report the User-set threshhold limit for Critical in percentage