Reference record for OID 1.3.6.1.4.1.232.165.5.3.1.1



parent
1.3.6.1.4.1.232.165.5.3.1 (mpduDeviceIdentTable)
node code
1
node name
mpduDeviceIdentEntry
dot oid
1.3.6.1.4.1.232.165.5.3.1.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqPower(165) trapTest(5) mpduDeviceIdent(3) mpduDeviceIdentTable(1) mpduDeviceIdentEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqPower(165) mpdu(5) mpduDeviceIdent(3) mpduDeviceIdentTable(1) mpduDeviceIdentEntry(1)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqPower(165) trapTest(5) mpduDeviceIdent(3) mpduDeviceIdentTable(1) mpduDeviceIdentEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqPower(165) mpdu(5) mpduDeviceIdent(3) mpduDeviceIdentTable(1) mpduDeviceIdentEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqPower(165) trapTest(5) mpduDeviceIdent(3) mpduDeviceIdentTable(1) mpduDeviceIdentEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqPower(165) mpdu(5) mpduDeviceIdent(3) mpduDeviceIdentTable(1) mpduDeviceIdentEntry(1)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqPower(165) trapTest(5) mpduDeviceIdent(3) mpduDeviceIdentTable(1) mpduDeviceIdentEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqPower(165) mpdu(5) mpduDeviceIdent(3) mpduDeviceIdentTable(1) mpduDeviceIdentEntry(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqPower/trapTest/mpduDeviceIdent/mpduDeviceIdentTable/mpduDeviceIdentEntry
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqPower/mpdu/mpduDeviceIdent/mpduDeviceIdentTable/mpduDeviceIdentEntry
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/hp/cpqPower/trapTest/mpduDeviceIdent/mpduDeviceIdentTable/mpduDeviceIdentEntry
  • /iso/org/dod/internet/private/enterprise/hp/cpqPower/mpdu/mpduDeviceIdent/mpduDeviceIdentTable/mpduDeviceIdentEntry
  • /iso/org/dod/internet/private/enterprises/compaq/cpqPower/trapTest/mpduDeviceIdent/mpduDeviceIdentTable/mpduDeviceIdentEntry
  • /iso/org/dod/internet/private/enterprises/compaq/cpqPower/mpdu/mpduDeviceIdent/mpduDeviceIdentTable/mpduDeviceIdentEntry
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqPower/trapTest/mpduDeviceIdent/mpduDeviceIdentTable/mpduDeviceIdentEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqPower/mpdu/mpduDeviceIdent/mpduDeviceIdentTable/mpduDeviceIdentEntry
  • Description by mibdepot

    The ident table entry containing the name, model,
    manufacturer, firmware version, part number... for
    each smart device, null value for unknown device.

    Parsed from file CPQPOWER1.62.MIB.txt
    Company: compaq
    Module: CPQPOWER-MIB

    Information by mibdepot

    mpduDeviceIdentEntry OBJECT-TYPE SYNTAX MpduDeviceIdentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The ident table entry containing the name, model, manufacturer, firmware version, part number... for each smart device, null value for unknown device." INDEX { mpduIdentIndex, mpduDeviceIdentIndex } ::= { mpduDeviceIdentTable 1 }

    Children (15)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.165.5.3.1.1.1 mpduDeviceIdentIndex 0 0 Index is based on the total number of Smart Extension Bars plus
    smart devices (with smart cord i.e. blades) detected.
    1.3.6.1.4.1.232.165.5.3.1.1.2 mpduDeviceStatus 0 0 The overall status of the device: off, on, problem.
    1.3.6.1.4.1.232.165.5.3.1.1.3 mpduDeviceUIDStatus 0 0 The overall status of the device UID: off, on, blink.
    1.3.6.1.4.1.232.165.5.3.1.1.4 mpduDeviceNumOutlet 0 0 The number of outlets of detected the device. This variable
    indicates the number of rows in the breakers table. Default is 5
    1.3.6.1.4.1.232.165.5.3.1.1.5 mpduDeviceUHeight 0 0 The U height of ext bar or device.
    1.3.6.1.4.1.232.165.5.3.1.1.6 mpduDevicePowerRating 0 0 The device's Power Rating in VA. Enter null if not detected.
    1.3.6.1.4.1.232.165.5.3.1.1.7 mpduDeviceManufacturer 0 0 The Device Manufacturer Name (e.g. Hewlett-Packard).
    Enter null if not detected.
    1.3.6.1.4.1.232.165.5.3.1.1.8 mpduDeviceType 0 0 The Device's Type: Ext Bar, server, or network device...
    1.3.6.1.4.1.232.165.5.3.1.1.9 mpduDeviceModel 0 0 The Device Model is Managed or Non-managed Ext Bar. Enter null if not detected.
    1.3.6.1.4.1.232.165.5.3.1.1.10 mpduDeviceName 0 0 The string identify the Device. i.e. 'BAR#1' (descriptive name)
    Enter null if not detected.
    1.3.6.1.4.1.232.165.5.3.1.1.11 mpduDeviceFirmwareVersion 0 0 The firmware revision level of Sm Ext Bar. Enter null if not detected.
    1.3.6.1.4.1.232.165.5.3.1.1.12 mpduDeviceHardwareVersion 0 0 The hardware version of Sm Ext Bar. Enter null if not detected.
    1.3.6.1.4.1.232.165.5.3.1.1.13 mpduDevicePartNumber 0 0 The device's part number. Enter null if not detected.
    1.3.6.1.4.1.232.165.5.3.1.1.14 mpduDeviceSerialNumber 0 0 The device's serial number. Enter null if not detected
    1.3.6.1.4.1.232.165.5.3.1.1.15 mpduDeviceUUID 0 0 The device's UUID. Enter null if not detected