Compaq SCSI Logical Drive Entry.
Parsed from file CPQSCSI1.MIB.txt
Company: None
Module: CPQSCSI-MIB
SCSI Logical Drive Entry.
Parsed from file CPQSCSI-MIB.mib
Module: CPQSCSI-MIB
cpqScsiLogDrvEntry OBJECT-TYPE SYNTAX CpqScsiLogDrvEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Compaq SCSI Logical Drive Entry." INDEX { cpqScsiLogDrvCntlrIndex, cpqScsiLogDrvBusIndex, cpqScsiLogDrvIndex } ::= { cpqScsiLogDrvTable 1 }
Vendor: Compaq
Module: CPQSCSI-MIB
[Automatically extracted from oidview.com]
cpqScsiLogDrvEntry OBJECT-TYPE SYNTAX CpqScsiLogDrvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SCSI Logical Drive Entry." INDEX { cpqScsiLogDrvCntlrIndex, cpqScsiLogDrvBusIndex, cpqScsiLogDrvIndex } ::= { cpqScsiLogDrvTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.5.2.3.1.1.1 | cpqScsiLogDrvCntlrIndex | 0 | 0 | SCSI Logical Drive Controller Index. The controller index indicates to which SCSI adapter instance this table entry belongs. |
1.3.6.1.4.1.232.5.2.3.1.1.2 | cpqScsiLogDrvBusIndex | 0 | 0 | SCSI Logical Drive Bus Index. The bus index indicates to which SCSI bus instance on an adapter this table entry belongs. |
1.3.6.1.4.1.232.5.2.3.1.1.3 | cpqScsiLogDrvIndex | 0 | 0 | SCSI Logical Drive Index. The logical drive index indicates to which logical drive instance on a SCSI bus this table entry belong… |
1.3.6.1.4.1.232.5.2.3.1.1.4 | cpqScsiLogDrvFaultTol | 0 | 0 | Compaq SCSI Logical Drive Fault Tolerance. This shows the fault tolerance mode of the logical drive. To change the fault toleranc… |
1.3.6.1.4.1.232.5.2.3.1.1.5 | cpqScsiLogDrvStatus | 0 | 0 | Compaq SCSI Logical Drive Status. The logical drive can be in one of the following states: other(1) The management agent does not … |
1.3.6.1.4.1.232.5.2.3.1.1.6 | cpqScsiLogDrvSize | 0 | 0 | SCSI Logical Drive Size. This is the size of the logical drive in megabytes. This value is calculated using the value 1,048,576 (… |
1.3.6.1.4.1.232.5.2.3.1.1.7 | cpqScsiLogDrvPhyDrvIDs | 0 | 0 | SCSI Logical Drive Physical Drive IDs. This lists the physical drive SCSI ID's which are associated with this logical drive. The… |
1.3.6.1.4.1.232.5.2.3.1.1.8 | cpqScsiLogDrvCondition | 0 | 0 | SCSI Logical Drive Condition. This is the overall condition of the logical drive and all of the physical drives which comprise it… |
1.3.6.1.4.1.232.5.2.3.1.1.9 | cpqScsiLogDrvStripeSize | 0 | 0 | Logical Drive Stripe Size. This is the size of a logical drive stripe in kilobytes. |
1.3.6.1.4.1.232.5.2.3.1.1.10 | cpqScsiLogDrvAvailSpares | 0 | 0 | SCSI Logical Drive Available Spares. This indicates if this logical drive has one or more spares designated for it that are not c… |
1.3.6.1.4.1.232.5.2.3.1.1.11 | cpqScsiLogDrvPercentRebuild | 0 | 0 | Logical Drive Percent Rebuild. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. T… |
1.3.6.1.4.1.232.5.2.3.1.1.12 | cpqScsiLogDrvOsName | 0 | 0 | Logical Drive OS Name. The OS name for this array logical drive. This field will be a null (size 0) string if the agent does not… |